Don't wait to get an Electrician

We make finding an electrician fast, easy, and commitment-free.

Call now (623) 259-4111
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >

Location and Projects

Address
104 Timber Cir, Buffalo, MN, 55313
Use our bidding system to request a quote

360 Electric

360 Electric at 104 Timber Cir, Buffalo, MN 55313, has a BuildZoom score of 105 and ranks in the top 8% of 77,973 Minnesota contractors.

If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.

360 Electric Services

Start a project today:

360 Electric Contact Information

Address: 104 Timber Cir, Buffalo, MN 55313 Edit

360 Electric Buffalo

Quality

105
92nd percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
360 Electric has a BuildZoom score of 105, which places them above 92% of 77,973 contractors in Minnesota.

Activity

40 projects
2025
58 projects
2024
11 projects
2023
Our building permit records indicate that 360 Electric has worked on at least 109.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

21 projects
Home Additions
109 projects
Electrical projects
Analyzing permits over the last 4 years shows that 360 Electric mostly works on electrical project and home addition projects.

Pricing

11 projects
< $5k
1 project
$5k-$20k
Value Not Public: 98.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by 360 Electric

Sort by: Notable Notable | Date Date | Job Value Job Value
Surge protection located at panel front exterior plug addition closet plug replace kitchen plugs replace three exhaust fans replace water softener plug laundry plug install gfci protection for upper level laundry in master bedroom
Valuation:
N/A
Permit #:
PE24-0359
Status:
final
Fee:
$51
Permit Type:
Electrical
Building Type:
N/A
Electrical permit
2024-07-30
- 20 amp ckt for main level office plug - addition recessed can lights in office - relocate dining light fixture and install new fan rated fixture box - install arc fault protection for modified branch ckts located at panel in basement. - 20 amp dedicated ckt to basement ceiling plug with gfci protection located at panel in basement
Valuation:
$1,000
Permit #:
20 24 058551 ELC 00 E
Status:
final
Fee:
N/A
Permit Type:
Electrical
Building Type:
N/A
Electrical permit
2024-08-05
- install gfci protection for basement bathroom plug - install arc fault and gfci protection for laundry plug water softener basement bar countertop plugs - install additional wiring to addition wall switch for existing basement bedroom light and install arc fault protection located at panel for modified branch ckt
Valuation:
N/A
Permit #:
ELE2408-01538
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-07-18
- install wiring in means to addition three additional lights in master bedroom hall bedroom and living room - install arc fault protection for that modified branch ckt located at panel in garage - install fan rated boxes for the three ceiling fans -repair reversed polarity in hall bedroom receptacle below switch
Valuation:
N/A
Permit #:
ELE2407-02312
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-06-19
- replace bathroom two plugs with gfci devices - replace one kitchen plug on north wall by refrigerator with dual function device - addition garage door opener plug with gfci device located down low on west wall - dedicated 20 amp sump pump ckt with gfci device located at sump pump
Valuation:
N/A
Permit #:
ELE2406-07496
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-09-12
- 150 amp new panel located in basement - emergency disconnect located on exterior of home - surge protection located at panel - update gfci protection for basement kitchen countertop area main level kitchen and laundry - update grounding system to water meter and exterior ground rods
Valuation:
N/A
Permit #:
ELE2407-05331
Status:
final
Fee:
$106
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-07-30
- re feed receptacles and lights on main level and 2nd level of home to eliminate knob and tube with dual function breaker located at panel - surge protection located at panel in basement - air conditioning mini split ckt - sump pump 20 amp ckt with gfci protection - refrigerator ckt with dual function breaker located at panel - bathroom ckt for receptacle with gfci protection - af/gf... see more
Valuation:
N/A
Permit #:
ELE2406-02456
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-05-17
- replace bathroom fan in upper and lower level - install gfci protection for lower level bathroom exhaust fan - install gfci protection located at panel for laundry plug - install gfci/afci for kitchen countertop plugs - replace five garage plugs ( gfci protected via upper bathroom gfci device) - replace three exterior plugs with wr plugs and extra duty in use covers - install gfci/a... see more
Valuation:
N/A
Permit #:
ELE2405-04673
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-05-17
- replace kitchen and breakfast nook receptacles with dual function breaker located at panel. - relocate dishwasher with dual function breaker located at panel - re-wire switch leg for breakfast nook light with dual function breaker located at panel - install fan rated box and ceiling fan for breakfast nook light. - install gfci protection for main level hall bathroom plug located nea... see more
Valuation:
$3,000
Permit #:
20 24 027205 ELC 00 E
Status:
final
Fee:
N/A
Permit Type:
Electrical
Building Type:
N/A
Electrical permit
2024-04-12
- install two dedicated 20 amp ckts from panel located in basement to second floor new laundry room.( dual function ckt breakers located at panel.) - install two additional recessed can lights located in new laundry room with arc fault protection located at panel in basement
Valuation:
N/A
Permit #:
ELE2404-03081
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-05-15
- dedicated 20amp multi-wire branch ckt to backyard shed with two receptacles and an overhead light - replace two bathroom gfci devices - install dual function device for one kitchen countertop plug to the right of the stove - install gfci protection for dishwasher and laundry plug via breaker located at panel in mechanical room - install gfci/afci protection for two basement bar plug... see more
Valuation:
N/A
Permit #:
ELE2402-07674
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-01-24
- install new plug for garbage disposal and re-wire switch located under sink and install dual function breaker for garbage disposal circuit located at panel in basement - install dedicated circuit for microwave with dual function breaker located at panel -install dedicated circuit for gas range induction oven with dual function breaker located at panel
Valuation:
N/A
Permit #:
ELE2401-06597
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-02-22
- relocate switch for kitchen recessed can light to kitchen wall to accommodate new countertops and install arc fault protection at panel located in garage - relocate switch for disposal underneath sink to accommodate new countertop and install arc fault protection at panel in garage for that multi-wire branch ckt and install gfci devises for disposal and dishwasher - install wiring f... see more
Valuation:
N/A
Permit #:
ELE2402-03741
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-05-24
- install recessed lighting and receptacles for basement area. install arc fault protection for new recessed lighting and afci/gfci protection for the new receptacles. install smoke/co device from existing wiring located outside the existing basement bedrooms and install arc fault protection for new smoke detector locations
Valuation:
N/A
Permit #:
ELE2402-01496
Status:
final
Fee:
$71
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-02-21
- replace sub panel located in basement and install whole home surge protector at new sub panel - install dual function breaker for main level living room and upper se bedroom ungrounded plugs - install new outlets in upstairs attic room with arc fault protection located at panel - install gfci protection for one garage plug located next to main panel and main level bathroom plug and ... see more
Valuation:
N/A
Permit #:
ELE2401-08959
Status:
final
Fee:
$61
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-11-01
- install aditional plug located on east side exterior with weather rated device and gfci protection - replace bedroom plugs and install arc fault protection located at panel -install dual function device for kitchen countertop plug left of sink
Valuation:
N/A
Permit #:
ELE2406-02460
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-02-12
- relocate master bathroom light switches to outside bathroom in hallway and install arc fault protection located at panel in basement for that ckt - 30 amp 240v dryer ckt with gfci protection located at panel in basement
Valuation:
N/A
Permit #:
ELE2401-08472
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2025-04-24
Basement living room finish - addition recessed light and receptacles with arc fault/gfci protection located at panel
Valuation:
$2,000
Permit #:
20 25 014469 ELC 00 E
Status:
final
Fee:
N/A
Permit Type:
Electrical
Building Type:
N/A
Electrical permit
2024-07-09
- 20 amp air conditioning circuit to unit located on back exterior of home from sub panel located on back exterior oh home - 20 amp circuit to plug located under exterior sub panel on back exterior of home
Valuation:
N/A
Permit #:
ELE2406-09797
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2024-10-07
- 20amp fireplace ckt with dual function breaker located at panel - 20amp bathroom plug ckt - 15amp general lighting and receptacle ckt with dual function breaker located at panel - addition smoke detector for bedroom and one combo unit for outside bedroom
Valuation:
N/A
Permit #:
ELE2408-09690
Status:
final
Fee:
$106
Permit Type:
One-family dwelling
Building Type:
N/A

Similar Contractors See more

License # EA709433
156
BZ Score
$5K
Avg Project
-
Projects
License # EA807569
133
BZ Score
$9.3K
Avg Project
-
Projects
License # BC756770
133
BZ Score
$13.1K
Avg Project
-
Projects

360 Electric Reviews

BuildZoom hasn't received any reviews for 360 Electric. Click here to be alerted when reviews are posted about them.
Please write a review about 360 Electric
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.