Their BuildZoom score of 114 ranks in the top 2% of 336,931 California licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Action Plumbing & Heating Maintenance, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Dig trench for replacement of water line from the meter to the house. line in 3/4 poly pipe. change to l copper approximately 35. includes new ball valve curb stop in meter box cut concrete (one square) and remove to access water meter to make repair. will need to return after inspected to repair sidewalk to santa rosa city specifications
Replace 50 gallon natural gas water heater in closed on porch needs to be replaced. closet needs to be re sheetrock it is ruined from mold. new pan pan drain line earthquake straps t & p line ran to exterior new water flex lines with shut off new dirt leg gas flex gas shut off. revised 4.10.25 install tankless water heater in same outside closet as original water heater. replace 50 ga... see more
Cut concrete sidewalk from (2) sidewalk squares to access water meter. replace approx. 40ft of galvanized water pipe from meter to house. replace water line with roll 3/4 copper pipe with sleeve. includes new ball shut off and pressure regulator at the house and new curb stop on customers side. line trench with sand under and above pipe backfill trench. repair cement sidewalk
Replace gas line from meter to house and granny unit. approx 210ft of 1 1/2 poly pipe under ground & 40ft of rigid 1 under house. we will cut and remove asphalt & concrete & trenching for asphalt & concrete. sand and backfill & patch asphalt & concrete rev 2/9/2024 disregard previous scope of work. corrected scope of work: replace gas line from meter to existing single family dwelling... see more
Replace existing lp 95% eff (17 1/2 cabinet) trane faf 80k btu up-flow with existing air conditioning. replace with payne/bryant 80k btu faf 95% eff. to include insulating cold air return install filter box new fused outlet new flex(gas) conversion kit. condensate needs to be 3/4 currently 1/2 and trap needs to be installed coming from coil
Install new 50 gallon american standard natural gas water heater with new earthquake straps water ball valve and flex lines expansion tank gas dirt leg t & p and pan with lines run outside
Replace 40 gallon natural gas water heater in closet. new pan elevated for fresh air vent. new ball valve earthquake straps run t&p line to exterior of building and pan drain to exterior of building. new water lines and dirt leg for gas
Replace 40gallon bradford white natural gas water heater in garage on stand with 40 gallon american standard natural gas water heater. new ball valve water flex lines dirt leg new pan with drain ran outside and t & p ran outside
Addition 4 ton air conditioning to 22 1/3 cabinet 50ft line set pad condenser coil (downflow) no space in zinsco panel. will need to run gas to dryer to make space in panel and change breaker to 40amp
Run water line from meter to house across driveway thru yard to corner of house. approx 50-55 includes digging trench running new 3/4 copper with sleeve from backflow to house and backfill hole and patching driveway. sand in trench 2 under pipe and 2 over pipe
Leak on main water line to house. cut sidewalk and remove broken concrete to get to meter. place delineators on both sides of open trench with caution tape and temporary platform for walking sidewalk traffic. replacing water line from meter to house with copper pipe. once repaired then backfill and compact trench and repair concrete sidewalk
Remove section of sidewalk by jack hammering out concrete to get to water line. put up caution tape and cones around open sidewalk. dig up main water line to house. replace water line with 3/4 copper line with sleeve. includes new shut off valve at house. replace section of sidewalk per city of santa rosa code standards
Run 50 at 3/4 water line from meter box to front half of duplex. we will use l copper install new 3/4 ball valve at house & new meter stop for new line and install new meter stop on existing line
Replace existing coleman 80k btu 50% efficiency with payne 40k btu 80% efficiency and replace existing coil & condenser with 2 ton coil and condenser on roof. includes new gas stop and flex sealing all boots and registers building 6 platform for filter box sealing plenum and new t-stat
Replacing faf and air conditioning units. new 80% afue 90 000 btu furnace new t-stat seal boots registers. using existing ducting and plenums. new 4-ton coil flush line set install new condenser and pad. condenser is 16seer
Replace existing 70, 000 btu 80% eff furnace with bryant 60, 000 btu 95%eff furnace in garage and 3 ton air conditioning. new coil condenser and line set. air conditioning unit located on west end of house on a pad
Emergency gas leak repair. pvc 1 1 4 leaking. line was excavated and repaired with common material. line replacement was not chosen due to the length of the gas line