Affinity Technologies Inc, 33 Dorchester Ln, Philadelphia, PA (Employees: Affinity One Inc and Peter M. Pshenitsyn) holds a Electrical Contractor license and 1 other license according to the Philadelphia license board.
Their BuildZoom score of 109 ranks in the top 5% of 125,106 Pennsylvania licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Affinity Technologies Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
For new construction of an attached three-story building with cellar second-floor rear deck roof deck and roof-deck access structure. building to be fully sprinklered with nfpa 13r. separate permits required for mechanical electrical plumbing fire suppression and excavation
For the erection of an attached structure with a roof deck and pilot house. structure for use as three (3) dwelling units. sprinklered through per nfpa 13r. separate permits required for plumbing mechanical electrical and fire suppression. a covered walkway or sidewalk closure shall be required in accordance with section 3306 of the ibc. separate building and/or streets department per... see more
Install 300 amp electrical service and 4 meter packs with proper grounding and bonding. install one subpanels for house and 3 subpanels for dwelling units. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec and per plans. (a separate fire alarm permit is require)
Install a 300 amp service (4) gang meter bank (1) 150 amp panel & feeder (2) 125 amp panels & feeders (1) 100 amp panel & feeder. install wiring throughout the common areas and three dwelling units. install lights normal & emergency switches sensors receptacles & smoke alarms. provide power for the mechanical & hvac equipment. all work in accordanc with the 2017 nec. * no fire alarm w... see more
For the erection of an attached three-story structure of type vb construction with a cellar and a roof deck with a roof access structure as per plans. for three (3) dwelling units with layout as shown
Install a 300 amp main electrical service wiring include outlets switches lights smoke alarms in all 3 units wiring of common areas fire alarm system installation per nfpa 72 2016 & philadelphia fire code 2018
New construction of a three (3) story single-family dwelling (irc 2015 townhouse construction) with roof deck and pilothouse (for access to roof deck) as per approved plans. building to be fully sprinklered. **separate permits required for mep & fire suppression work** amendment issued on 6/1/2022 to document the change of pilothouse roof slope
Installation of new 400amp main electrical system new wiring include: outlets switches smoke alarms lights new fire alarm system. all work is to be done according to approved drawings-2017 nec 2016 nfpa-72
Install 400 amp electrical service and 4 meter packs with proper grounding and bonding. install 4 circuit breaker panels and breakers for house commercial space adn 2 dwelling unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec and per plans. ******************** separate fire alarm permit is require *****... see more
Install a 300 amp service (4) gang meter bank (3) 125 amp panels & feeders (1) 100 amp panel & feeder. install wiring throughout the common areas & three dwelling units. install lights normal & emergency switches sensors receptacles & smoke alarms. provide power for the mechanical & hvac equipment. all work in accordance with the 2017 nec. ** no fire alarm work on this permit
Install 400 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec. (a separate fire alarm permit is require)
Install 400 amp electrical service and 5 meter packs with proper grounding and bonding. install 5 circuit breaker panels one for house and 4 for dwelling units. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms. install fire alarm system according to the 2017 nec nfpa 72 and per plans
Install 400 amp electrical service and 4 meter packs with proper grounding and bonding. install 4 circuit breaker panels and breakers for house commercial space adn 2 dwelling unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec and per plans. ******************** separate fire alarm permit is require *****... see more
Install 300 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec. (a separate fire alarm permit is require)
Install 300 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec and per plans. (a separate fire alarm permit is require)
Install 300 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec. (a separate fire alarm permit is require)
Install 300 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec. (a separate fire alarm permit is require)
Install 300 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec and per plans. (a separate fire alarm permit is require)
Install 300 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec. install fire alarm system according to the 2016 nfpa 72 and per plans
Install 300 amp electrical service and 4 meter packs with proper grounding. install 4 circuit breaker panels and breakers for house and 3 unit. install wiring lighting switches and receptacle outlets. install interconnected smoke and co alarms according to the 2017 nec. (a separate fire alarm permit is require)