We'll help you find the right contractor.

Share your project details and we'll reach out to AJ Electric so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started

Location and Projects

Address
626 E Cambridge Ave, Visalia, CA, 93292
Use our bidding system to request a quote

AJ Electric

AJ Electric, 626 E Cambridge Ave, Visalia, CA (Employees: Aleksey Neverov, Avi Haberfeld, and Jeffrey Thomas Hulse) holds a Electrical license and 4 other licenses according to the California license board.

Their BuildZoom score of 105 ranks in the top 8% of 336,931 California licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring AJ Electric, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

AJ Electric Contact Information

Phone: (808) 378-8993
Address: 626 E Cambridge Ave, Visalia, CA 93292

AJ Electric Visalia

Quality

105
92nd percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
AJ Electric has a BuildZoom score of 105, which places them above 92% of 336,931 contractors in California.

Activity

8 projects
2025
8 projects
2024
5 projects
2023
Our building permit records indicate that AJ Electric has worked on at least 21.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

21 projects
Electrical projects
Analyzing permits over the last 4 years shows that AJ Electric mostly works on electrical project projects.

Pricing

3 projects
< $5k
Value Not Public: 17.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by AJ Electric

Sort by: Notable Notable | Date Date | Job Value Job Value
Replace knob and tube wiring in living room dining room kitchen entry hallway washroom bathroom master bed 2 bedrooms master bathroom stairway and lower room on garage level with lower bathroom and lower kitchens. installed 1 new 90 amp 120/240v subpanel
Valuation:
N/A
Permit #:
EW202507157981
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
In compliance to nov 202179317 according to pa202109309560 and pa 202402296781 (rev) which is to legalized (e) 3 storage rooms. 3 lights 2 switches
Valuation:
N/A
Permit #:
E202503311304
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Owner of building is permitting previously completed work in unit #4 to bring it to code as it was completed without benefit of permit and or inspection. walls were covered although owner has some pictures
Valuation:
N/A
Permit #:
EW202402066571
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Change main electrical service from 100amps 120/240v to 200 amps 120/240v and move main disconnect to outside of building. install 1 car charger station in garage
Valuation:
N/A
Permit #:
EW202509079242
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Changed main electrical service from100 to 200 amp 120/240v single phase 3 wire. 3 2/0 feeders. existing under ground untilized. installed 1 50 amp 4 wire outlet at main service for ev charger
Valuation:
N/A
Permit #:
EW202401066012
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Express electrical permit - residential
2025-05-09
Install an electrical 100a sub panel next to the existing electrical sub panel in garage
Valuation:
$2,100
Permit #:
EW25-0272
Status:
final
Fee:
$512
Permit Type:
N/A
Building Type:
N/A
Provide and install temp power to replace the original that was burnt by the palisades fire
Valuation:
N/A
Permit #:
25041-90000-09602
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
Change main electrical service from 100 amp 120/240v to 200amp 120/240v with meter/main location moved to front of building. install 1 ev charger outlet 50amp 120/240v
Valuation:
N/A
Permit #:
EW202407099779
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace the existing zinsco panels with new siemens panels and breakers
Valuation:
N/A
Permit #:
25041-90000-08034
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Unit #5: addition 2 20amp/120v branchcircuits for 2 bedrooms
Valuation:
N/A
Permit #:
E202501149324
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Residential electrical
2025-03-26
Electric panel replacement at ex single family residence
Valuation:
N/A
Permit #:
K202502204
Status:
issued
Fee:
$38
Permit Type:
N/A
Building Type:
N/A
Removed knob and tube and rewired to code change main electrical service to a 200 amp 120/240volt single phase 3 2/0 wire with pge meter located on exterior
Valuation:
N/A
Permit #:
EW202302038795
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Upgrade service/repair due to rust with no added load. 200 amp 120/240v 1phase 1 meter riser 1 2” pipe 3 2/0 feeders 1 #4 wire ground w 2 ground rods and 14 circuits new grounding new bonding at hot water heater new light switch and gfi outlet at main service location
Valuation:
N/A
Permit #:
EW202002076527
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove the old cloth insulated wires and replace with the new wires provide and install new kitchen outlets provide new circuits for kitchen bathroom laundry air conditioning unit. upgrade the existing sub panel
Valuation:
N/A
Permit #:
19041-90000-46104
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
This permit is to obtain final inspection and clear out three expired permits. permit e201704174345 e201704174346 e202003168238
Valuation:
N/A
Permit #:
EW202304130371
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 1 8/16 50 amp subpane in common area garage.l. install new lighting and circuit throughout unit including smoke and co protection. installed additional outlets in bedroom living and bathroom. installed all new wiring kitchen. install deck light off kitchen added 1 gfi in toilet moved 1 gfi in shower room. installed 1 closer light near front entrance
Valuation:
N/A
Permit #:
EW201902158806
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Re-wiring the entirety of the unit to bring up to current code including a new 70 amp subpanel fed with 3 #4 wire thhn change of service to occur under this permit although still awaiting inital meeting from pge proposed service change is a 7 meter 400amp 120/240volt
Valuation:
N/A
Permit #:
EW201806193773
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Change main electrical service from 100 amp to 200 amp 120/240v install 1 50amp ev charger
Valuation:
N/A
Permit #:
EW202404077844
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Change main electrical service to a 200 amp 129/240volt with 40 circuit panel board new ground new light switch and outlet and panel location. meter to be located on exterior with main and distribution in garage
Valuation:
N/A
Permit #:
EW201912095321
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 1 60 gfi protected hot tub disconnect and feed. install 2 gfci protected outlets in rear yard. cover up insp required
Valuation:
N/A
Permit #:
EW202109018114
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

AJ Electric Reviews

BuildZoom hasn't received any reviews for AJ Electric. Click here to be alerted when reviews are posted about them.
Please write a review about AJ Electric
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.