Share your project details and we'll reach out to
American Fire Protection Group Inc
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
American Fire Protection Group Inc, 5525 Eastcliff Industrial Loop, Birmingham, AL (Employees: Charles Robert Roy, Jeffrey A Hewitt, and Lance Dalton Mosley) holds a General Contractors license and 6 other licenses according to the Alabama license board.
Their BuildZoom score of 95 ranks in the top 22% of 28,929 Alabama licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring American Fire Protection Group Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
American Fire Protection Group Inc Contact Information
Replacement of manual wet stanpipe and new sprinkler system for shell floors 3 & 4 with new sprinkler system for penthouse. drawings fp 1, 2, 3, 7, 8,9, & 10. asnt - added notes identifying which standpipe calc is for which fdc, and to provide permanent all weather sign with demand requirements or standpipe system. 12/31/2015 rft
Turning sprinkler drops from pendent position up to upright position, relocating as req'd for coverage & installing new sprinklers. asnt - noted 2 sprinklers at 7'6" max from walls. added note to verify and maintain minimum 6' on center. 7/7/2015rft
Add water curtain to protect un-rated glass in 2 hr fire wall. asnt - glass type and installation is to comply with ibc, '09 ed, section 406.6, exception #1 and nfpa 13, '07 ed, section 21.20.1.2.1(3).
Change standard response sprinklers to quick response & add & relocate sprinklers for new walls. asnt - move one sprinkler in men's vanity. 9/17/2015 rft post permit revisions #1. 9/29/22015 rft
Relocate 3 sprinkler heads for new wall and ceiling lay out. material-10'-1' pipe, 3-1' 90's, 21x1/2 bell reducers, 1-1x3/4 bell reducers, 3-1' hanger rings, 3 beam clamps, 12'-1/2 rod. no plans required. 12/3/2014 rft
Installing a new pre-action system for new main ter and ups room. (9-17-13 post permit revisions) revised to include tr on levels g thru 7, excluding 4. asnt - added note "6' min. or add baffle" for two sprinklers in primary tr levels 2, 3, & 5. 9/19/2013 rft post permit revisions #2 fp1 add sprinklers to level g & 1st. floor stair and passage. revision #1 fp6 change sprinklers to qr ... see more
Plug (1) sprinkler outlet and relocate (1) sprinkler 10'-6 sch. 40 pipe (2) 1 90 degree cast iron elbows (1) new sprinkler (1) hanger with wedge anchor 3/8 all thread rod and (1) hanger ring
Relocating and adding sprinklers for new wall layout. asnt - change relocate to add for one sprinkler. add max. dimension from wall for another. 7/24/2015 rft
Install fire sprinkler systems on 5th floor mechanic floor. asnt - fp34 add pendent under duct at 7-8 bd near column line sd on north side where duct steps up to 13-11bd. add upright at column line rf ne of corner column over duct. fp35 added max. dimension between upright sprinklers at elevator #5. fp36 added max dimension for sprinkler near node 101. added max. dim. for sprinkler li... see more
Install sprinklers in press pit & scrap tunnel. asnt - typical all branch lines in narrow beam channel: branch line to be centered in space. deflector may be a max of 2 ?" above the bottom of the beam at minimum 1' from near edge of beam flange & max of 22" from deck. see nfpa 13, '07 ed, table 8.6.5.1.2. 10/31/11 rft
Fire sprinkler system. asnt - on sheets 44 and 46 moved one sprinkler 2' in dialysis 074316 and added minimum 8' dimension in nurse station 073347. on sheet 48 and 50 added minimum 8' dimension in junction of corridors 083364 and 084403. on sb26 moved two hangers as indicated. on sb27 add one and move one as indicated. on sb28 mover two and add maximum 40' dimension. 10/5/11 rft
Relocate existing sprinkler drops with new quick response sprinklers. asnt - added note in adjoining spaces to "verify that sprinklers are not over spaced from wall due to this work." i.e. the demising wall has not been moved. 3/29/12 rft
Inside sprinkler system from 1'-0" above finished floor. asnt - did not use or review "concealed 2nd. floor calcs on fp-4. 12/10/2012 rft post permit revisions. 12/14/12 rft post permit revisions 1/10/13 rft
BuildZoom verified this license was active as of November 2025.
Verify this license's status for American Fire Protection Group Inc at the Alabama Licensing Board for General Contractors.
This is a sample of licensing data; click here to access a complete history.
Verified License
License #
56767
Status
Active
State
Louisiana
Type
Telecommunications, Low Voltage
Class
Commercial License Certificate
BuildZoom verified this license was active as of March 2026.
Verify this license's status for American Fire Protection Group Inc at the Louisiana Licensing Board.
This is a sample of licensing data; click here to access a complete history.
Verified License
License #
32414
Status
Active
State
North Carolina
Type
Fire Sprinkler Installation Contractor
BuildZoom verified this license was active as of December 2025.
Verify this license's status for American Fire Protection Group Inc at the North Carolina Board Of Examiners of Plumbing, Heating and Fire Sprinkler Contractors.
This is a sample of licensing data; click here to access a complete history.
Verified License
License #
47873
Status
Active
State
Alabama
Type
General Contractors
BuildZoom verified this license was active as of January 2026.
Verify this license's status for American Fire Protection Group Inc at the Alabama Licensing Board for General Contractors.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
License #
S-51006
Status
Active
State
Alabama
Type
General Contractors
When BuildZoom last verified this license, it had an expiration date of December, 2022. Check the current license status of American Fire Protection Group Inc with the Alabama Licensing Board for General Contractors
This is a sample of licensing data; click here to access a complete history.
Inactive License
License #
51874
Status
Inactive
State
Louisiana
Type
Business And Law, Specialty: Fire Sprinkler Work
Class
Commercial License
According to the Louisiana Licensing Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for American Fire Protection Group Inc at the Louisiana Licensing Board.
This is a sample of licensing data; click here to access a complete history.
Inactive License
License #
42023
Status
Inactive
State
Alabama
Type
General Contractors
According to the Alabama Licensing Board for General Contractors, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for American Fire Protection Group Inc at the Alabama Licensing Board for General Contractors.
This is a sample of licensing data; click here to access a complete history.