Share your project details and we'll reach out to
Andrews & Moore Contracting LLC
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Andrews & Moore Contracting LLC at 643 Schuyler Ave, Rock Hill, SC 29730, held a license (#77153) with the North Carolina contractors license board. We last verified the license was expired on 12-13-2024.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 79,084 South Carolina contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Andrews & Moore Contracting LLC Contact Information
Project 20110036 repair wind and water damage only brothers heating & cooling **no upfit work permitted, only issued to replace like for like interior coverings, electrical, plumbing, mechanical**
Interior repair from roof leak, sheetrock, insulation, flooring, suspended ceiling tiles, inspect electrical, hvac and fire alarm system, stucco repair in one area of exterior wall. project 20190210
Approval to demo existing finishes and interior upfit - construct new offices and finishes per plans and specs. project number 20161002. subcontractors included in permit.
Approved to construct 842 sq. ft. outdoor shelter by pool area with grill, sink, refrigerator and fireplace per plans. collect $221.00 impact fees. project number 20161192. setbacks approved as shown on site plan. setbacks measured from exterior building wall per section 5-200(c) of rh zoning ordinance. subcontractors included in permit. conditions: must be accessible as required in a... see more
Approved for exterior renovations. tear off metal shed roof at rear of building. install felt over wood deck and install metal roof system. attach one layer of iso insulation over roof. attach one white .060 tpo roof system over new insulation, new 1/2" treated plywood over all parapet walls for new wall flashing. new sheetmetal counter flashing and drip edge. 10 year versico tpo roof... see more
Approval to convert former florist shop to art gallery with classes for small groups. new bathroom, rear platform, steps, deck handicap ramp. open two cased openings. demo non-load bearing wall. install piers and drop seal. replace front and rear door. project number 20170519. plumbing subcontractor included in this permit. see conditions.
Approved to remove and replace 14 windows per plans and specs. certificate of appropriateness 969 issued by staff to replace non-historic windows on secondary façade with new windows that will not change the dimensions of the existing window openings.. project number 2016037.
Approved for interior upfit, adding landscaping and parking for car sales and repair per plans and specs. includes 862, 874, 886 and 888 s. anderson road. project number 20160029 - european auto masters. electrical subcontractor included in this permit. collect $1512 impact fees.property was recently annexed into city. see conditions. 4/27/17 - change order approved: maintain oil chan... see more
Approval to remove and replace the roof decking, new knee walls, remove and replace roof with a .060 versico tpo roof system. remove and replace the boxing, remove and replace beam with two microlams with footings per plans and specs. project number 20130523. coa number 978 approved by staff. no subcontractors included in permit. see conditions listed.
Valuation:
$17,720
Permit #:
201700668
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Single family residential additions or renovations
Frame 2 new closet, one in bedroom and one in new bathroom. new bathroom between upstairs bedroom and bonus room. new bar and cabinets in bonus room. project 20170790 subcontractors included in permit.
Removal of several interior non-load bearing walls. renovation and demolition of most facilities are subject to state and federal asbestos regulations. the facility owner and the renovation or demolition contractor are both responsible for ensuring compliance with these regulations. please visit http://www.scdhec.gov/environment/baq/asbestos/regulatory_information.asp for more informa... see more
Interior upfit - ada restroom upfit. plumbing subcontractor included in permit. project 20170161 simply amazing woodwork. 5/4/17 added to scope of work - moving 2 outlets and 2 light fixtures (one with fan). ok per mike nugent.
Approved for interior demolition and upfit to build fire wall and remodel bathrooms to make ada accessible per plans and specs. project number 20160785. subcontractors included in permit. see conditions.
Exterior and interior renovation roof renovation. paint booth addition screen fence and gravel area for car storage per plans. project# 20170410 edwards body shop
Approved to repair floor and roof due to water damage, ceiling tiles, insulation and electric service change out per plans and specs. project number 20171104
Approved for interior demolition and restroom renovations for ada requirements per plans and specs. project #20171266. subcontractors included in permit
According to the North Carolina Licensing Board for General Contractors, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Andrews & Moore Contracting LLC at the North Carolina Licensing Board for General Contractors.
This is a sample of licensing data; click here to access a complete history.