We'll help you find the right contractor.

Share your project details and we'll reach out to Ascend Wireless Networks Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >

Location and Projects

Address
741 GARDEN COMMERCE PKWY, Winter Garden, FL, 34787
Use our bidding system to request a quote

Ascend Wireless Networks Inc

Ascend Wireless Networks Inc, 741 Garden Commerce Pkwy, Winter Garden, FL (Owned by: Alan Zirkelbach) holds a Certified Contractor license and 33 other licenses according to the Ocala license board.

Their BuildZoom score of 113 ranks in the top 3% of 191,428 Florida licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Ascend Wireless Networks Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Ascend Wireless Networks Inc Contact Information

Phone: (731) 220-1027 Edit
Address: 741 GARDEN COMMERCE PKWY, Winter Garden, FL 34787 Edit

Ascend Wireless Networks Inc Winter Garden

Quality

113
97th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Ascend Wireless Networks Inc has a BuildZoom score of 113, which places them above 97% of 191,428 contractors in Florida.

Activity

80 projects
2025
72 projects
2024
109 projects
2023
Our building permit records indicate that Ascend Wireless Networks Inc has worked on at least 261.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

34 projects
Home Additions
4 projects
New Constructions
Analyzing permits over the last 4 years shows that Ascend Wireless Networks Inc mostly works on home addition and new construction projects.

Pricing

25 projects
< $5k
49 projects
$5k-$20k
64 projects
$20k-$50k
17 projects
$50k-$100k
2 projects
$100k-$250k
2 projects
$500k-$1mil
Value Not Public: 85.0 projects
The typical size of their permits is approximately $20,000. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Ascend Wireless Networks Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Building permit
2025-03-20
No Description Available
Valuation:
$55,000
Permit #:
BLD2025-11433
Status:
issued
Fee:
N/A
Permit Type:
Alteration
Building Type:
N/A
Commercial - commercial
2025-01-29
****commercial****at existing telecommunication tower modify six antennas. also remove/replace non-electrical support devices. at equipment platform replace communication cabinet and support devices. replace 35kw lp generator for 50kw generator. retain existing lp tank ilc and generac ats.***noc needed***
Valuation:
$45,000
Permit #:
BLD2024334400
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Clay county - electrical (commercial) - alteration remodel repair
2025-03-07
Tower work: remove (9) antenna(s) (6) rrh(s) and (15) 1-5/8 coax cable(s) install mount modifications (9) antenna(s) (6) rrh(s) (1) ovp(s) and (1) 1.43 6x12 hybrid cable(s) existing (3) antenna(s) (2) ovp(s) (3) 1-5/8 coax and (2) 1.43 6x12 hybrid cable(s) to remain ground work: remove (1) 6201 cabinet install (1) router (1) baseband (1) siteboss and (1) upconverter
Valuation:
$20,000
Permit #:
ELC0924-0671
Status:
complete
Fee:
$144
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-11-29
Tower scope of work: ¿remove (2) jma wireless - axp19-60 antennas ¿remove (1) jma wireless - x7-fro-660-4 antennas ¿remove (4) css antenna - axp19-45 antennas ¿remove (2) jma wireless - x7c-fro-640-2 antennas ¿remove (3) commscope - cdx623t-ds combiners ¿remove (2) commscope - 1-5/8 coaxial cables ¿ install mount modification by colliers engineering & design dated 03/03/2025 ¿ install... see more
Valuation:
N/A
Permit #:
E25006986
Status:
expired
Fee:
$112
Permit Type:
Commercial
Building Type:
Alteration
Electrical permit
2025-11-29
Tower scope of work: ¿remove (2) jma wireless - axp19-60 antennas ¿remove (1) jma wireless - x7-fro-660-4 antennas ¿remove (4) css antenna - axp19-45 antennas ¿remove (2) jma wireless - x7c-fro-640-2 antennas ¿remove (3) commscope - cdx623t-ds combiners ¿remove (2) commscope - 1-5/8 coaxial cables ¿ install mount modification by colliers engineering & design dated 03/03/2025 ¿ install... see more
Valuation:
N/A
Permit #:
E25006986
Status:
expired
Fee:
$112
Permit Type:
Commercial
Building Type:
Alteration
Electrical permit
2025-05-16
(outdoor cabinets) remove 6101 equipment cabinet. remove cdma cabinet. remove (3) 4449s and (3) 8843s from h-frame. remove (3) tbc-67c-a-p-2sf jma tri- combiners and bc61923-ds-43 commscope triplexers. install consolidated equipment cabinet with (5) 75a rectifiers in power plant. install router bbus gps equipment and site boss in new cabinet. install (3) 4490s 4890s and (3) 8863s on h... see more
Valuation:
N/A
Permit #:
E25006428
Status:
complete
Fee:
$62
Permit Type:
Commercial
Building Type:
Alteration
Commercial permit
2025-05-15
(outdoor cabinets) remove 6101 equipment cabinet. remove cdma cabinet. remove (3) 4449s and (3) 8843s from h-frame. remove (3) tbc-67c-a-p-2sf jma tri- combiners and bc61923-ds-43 commscope triplexers. install consolidated equipment cabinet with (5) 75a rectifiers in power plant. install router bbus gps equipment and site boss in new cabinet. install (3) 4490s 4890s and (3) 8863s on h... see more
Valuation:
N/A
Permit #:
B25901955
Status:
complete
Fee:
$698
Permit Type:
Non-census
Building Type:
Alteration
Clay county - electrical (commercial) - alteration remodel repair
2025-09-26
Tower work: remove (9) antenna(s) (6) rrh(s) and (6) 1-5/8 coax cable(s) install (9) antenna(s) (6) rrh(s) (3) back-to-back rru bracket(s) existing (3) antenna(s) (1) ovp(s) and (4) 1-5/8 coax and (2) 1.43 6x12 hybrid cable(s) to remain ground work: remove (1) 7 x 4 concrete pad (1) 250 gallon propane tank (1) generic cabinet (1) cdma cabinet (1) 6291 cabinet (1) battery cabinet all b... see more
Valuation:
N/A
Permit #:
ELC0525-0155
Status:
complete
Fee:
$323
Permit Type:
N/A
Building Type:
N/A
Tower scope of work: • remove (3) ericsson - air6449 antennas • remove (3) ericsson - 8843 radios • remove (1) raycap - 6 ovp • install (3) ericsson - air 3283 antennas • install (3) ericsson - air6419 antennas • install (3) ericsson - 4490 radios • install (1) raycap - ovp - 12 ovp • install (1) 6 x 12 hybriflex hybrid cable ground scope of work: • remove (3) ericsson - 2212 b13 radi... see more
Valuation:
$65,000
Permit #:
P25-009172
Status:
issued
Fee:
$603
Permit Type:
N/A
Building Type:
N/A
City fire permit
2025-01-23
Adding (12) antennas removing (6) antennas adding (3) rrus removing (3) rrus adding (1) hybrid adding (1) ovp removing (1) ovp. ground sow: remove 6120 equipment with (6) rul01 b13s. replace ovp-6 (3315) with ovp-12 (6627). install consolidated equipment cabinet with (4) 75a rectifiers in power plant. install router bbus gps equipment upconverter and site boss in new the cabinet. repl... see more
Valuation:
$65,000
Permit #:
25FP00037
Status:
final
Fee:
$308
Permit Type:
N/A
Building Type:
N/A
Commercial miscellaneous
2024-12-02
Verizon is adding (9) antennas removing (6) adding (6) rrus removing (6) removing coax. ground sow: remove (2) 6101 cabinets with (6) rul01 b13s. remove cdma cabinet. remove (3) diplexers from h-frame. replace (1) bottom ovp-6 (3315) with an ovp-12 (6627). install consolidated equipment cabinet with (5) 75a rectifiers in power plant. install router bbus gps equipment upconverter and s... see more
Valuation:
$75,000
Permit #:
24BC22186
Status:
final
Fee:
$1,173
Permit Type:
N/A
Building Type:
N/A
Commercial miscellaneous
2025-08-12
The proposed project includes modifying ground based and tower mounted equipment as indicated per below: tower work: remove (6) diplexer(s) and (12) 1-5/8 coax cable(s) install mount modifications (3) antenna(s) (6) rrh(s) (1) ovp(s) and (2) 1.43 6x12 hybrid cable(s) existing (6) antenna(s) to remain ground work: remove (1) 6101 cabinet (6) rul01 (3) rus01b4 (1) cdma cabinet (3) tripl... see more
Valuation:
$29,000
Permit #:
25BC15442
Status:
issued
Fee:
$769
Permit Type:
N/A
Building Type:
N/A
Commercial permit
2025-11-28
Verizon is upgrading equipment at existing cell tower no change to tower height or compound size. equipment to include antennas radios ovp's cabinets and batteries. see construction drawings for complete details
Valuation:
N/A
Permit #:
B25902291
Status:
expired
Fee:
$530
Permit Type:
Non-census
Building Type:
Alteration
Commerical alteration
2025-06-01
At existing cell tower install mount modification and 3 antennas. at grade replace cabinets and addition non-electrical support devices. replace 30 kw lp generator with 50 kw lp generator
Valuation:
$45,000
Permit #:
P25-0489
Status:
issued
Fee:
$544
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-03-04
Tower work: remove (15) rrh(s) and (6) diplexer(s) install (3) antenna(s) and (6) rrh(s) existing (6) antenna(s) (2) ovp(s) and (6) 1-5/8 coax & (3) 1.43 hybrid cable(s) to remain ground work: remove (1) 30kw generator (1) ppc/ats (2) cabinet (3) rrh(s) (3) diplexer(s) and (1) sub panel install (1) cabinet (1) router (1) bbus (1) gps antenna (1) upconverter and (1) site boss (1) ppc/a... see more
Valuation:
N/A
Permit #:
E25002700
Status:
complete
Fee:
$86
Permit Type:
Commercial
Building Type:
Alteration
Clay county - electrical (commercial) - alteration remodel repair
2025-09-11
Tower work: remove (6) antenna(s) (6) rru(s) (1) ovp(s) (7) 1-5/8 coax cable(s) and (1) 12x24 (1-5/8") hybrid cable(s). install (9) antenna(s) (3) rru(s) (2) 6x12 (1.43") hybrid cable(s) and mount modification(s). existing (6) antenna(s) (1) ovp(s) (1) 12x24 hybrid (1-5/8") cable(s) and (3) 1-5/8 coax cable(s) to remain. ground work: remove (1) cdma cabinet(s) (1) ode cabinet(s) (1) b... see more
Valuation:
N/A
Permit #:
ELC0825-0315
Status:
issued
Fee:
$215
Permit Type:
N/A
Building Type:
N/A
Clay county - electrical (commercial) - alteration remodel repair
2025-09-11
Tower work: remove (6) antenna(s) (6) rru(s) (1) ovp(s) (7) 1-5/8 coax cable(s) and (1) 12x24 (1-5/8") hybrid cable(s). install (9) antenna(s) (3) rru(s) (2) 6x12 (1.43") hybrid cable(s) and mount modification(s). existing (6) antenna(s) (1) ovp(s) (1) 12x24 hybrid (1-5/8") cable(s) and (3) 1-5/8 coax cable(s) to remain. ground work: remove (1) cdma cabinet(s) (1) ode cabinet(s) (1) b... see more
Valuation:
N/A
Permit #:
ELC0825-0315
Status:
issued
Fee:
$215
Permit Type:
N/A
Building Type:
N/A
Commercial miscellaneous
2025-05-05
Verizon is upgrading tower and ground equipment at existing cell tower. equipment to include antennas rrus diplexers coax cabinets and batteries
Valuation:
$75,000
Permit #:
25BC08607
Status:
final
Fee:
$1,143
Permit Type:
N/A
Building Type:
N/A
Commercial miscellaneous
2025-05-05
Verizon is upgrading tower and ground equipment at existing cell tower. equipment to include antennas rrus diplexers coax cabinets and batteries
Valuation:
$75,000
Permit #:
25BC08607
Status:
final
Fee:
$1,143
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-03-26
No Description Available
Valuation:
$25,000
Permit #:
ELE2025-11653
Status:
issued
Fee:
N/A
Permit Type:
Alter
Building Type:
N/A

Similar Contractors See more

License # ES12001748
100
BZ Score
$454K
Avg Project
-
Projects
License # EF20001786
110
BZ Score
$16.8K
Avg Project
-
Projects
License # SCC131151555
105
BZ Score
$40K
Avg Project
-
Projects

Ascend Wireless Networks Inc Reviews

BuildZoom hasn't received any reviews for Ascend Wireless Networks Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Ascend Wireless Networks Inc
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.