×

We'll help you find the right contractor.

Share your project details and we'll reach out to Avalanche Air Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Location and Projects

Address
14712 Raymer St, Van Nuys, CA, 91405
Use our bidding system to request a quote

Avalanche Air HVAC/Mechanical Contractor

Avalanche Air Inc at 14712 Raymer St, Van Nuys, CA 91405, held a HVAC/Mechanical Contractor license (#855953) with the California contractors license board with an expiration date of 03-31-2027. We last verified the license was suspended on 06-30-2026.

Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.

If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.

Avalanche Air Inc Services

Start a project today:

Avalanche Air Inc Contact Information

Phone: (818) 597-2665
Address: 14712 Raymer St, Van Nuys, CA 91405

Building Permits by Avalanche Air Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Violation number: 23-sma-208-k-5217 date issued: 6/8/2023 issued by inspection type: final violation type: permit required violation code section: 95.111.2 lamc code language: obtain the required permit for all mechanical heating ventilating air-conditioning or refrigeration equipment or other miscellaneous heat-producing appliances listed below. violation notes: 2- smoke fire dampers... see more
Valuation:
N/A
Permit #:
23044-90000-14964
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Instalation of (1) new mitsubishi ducted vrf dual-zone heat pump split system that consist of; (1) new mitsubishi 3ton ducted wall mount indoor units (model #mpeada36aa8) (1) gl series 12, 000 btu wall mount indoor unit and (1) new mitsubishi 4ton heat pump outdoor condensing unit (model #mmxzsm48namu1). new ductwork (11) vents
Valuation:
N/A
Permit #:
23044-90000-03499
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
Installation of (3) hp split systems that consist of (3) indoor air hadler units and (3) outdoor condensing units with a total of (4) inlets/outlets
Valuation:
N/A
Permit #:
23044-20000-04355
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Installation of (2) hp split systems that consist of (2) indoor air hadler units and (2) outdoor condensing units with a total of (4) inlets/outlets
Valuation:
N/A
Permit #:
23044-20000-04354
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Installation of (2) hp split systems that consist of (2) indoor air hadler units and (2) outdoor condensing units with a total of (4) inlets/outlets
Valuation:
N/A
Permit #:
23044-20000-04353
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Installation of (2) hp split systems that consists of (2) indoor air handler units and (2) outdoor condensing units. with a total of (4) inlets and outlets
Valuation:
N/A
Permit #:
23044-90000-03715
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Hvac installation of (2) new four - zone heat pump split systems (8) new tri- zone heat pump split systems (1) new duel- zone heat pump split system and (1) new single - zone heat pump split system
Valuation:
N/A
Permit #:
21044-90000-03802
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Instalation of (2) hp split systems that consists of (2) indoor air handler units and (2) outdoor condensing units with a total of (4) inlets/outlets
Valuation:
N/A
Permit #:
23044-90000-03714
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Installation of (3) hp split systems that consist of (3) indoor air hadler units and (3) outdoor condensing units with a total of (6) inlets/outlets
Valuation:
N/A
Permit #:
23044-90000-03716
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Install (2) heat pump air handlers and (1) condensers in basement theater and multi-purpose room. modify ductwork for (1) existing air handler relocate exhaust in new laundry room
Valuation:
N/A
Permit #:
21044-90000-01702
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
Revisions to previously approved plan 19044-10000-10762. addition of (2) bathroom exhaust fans kitchen exhaust and dryer exhaust
Valuation:
N/A
Permit #:
20044-10000-11847
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Plan check for heating venting air conditioning and product conveying systems
Valuation:
N/A
Permit #:
20044-10000-00342
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Installation of (23) ptac hvac units (22) bathroom exhaust ducts (22) kitchen exhaust ducts (6) fire dampers (6) corridor exhaust fans
Valuation:
N/A
Permit #:
24044-90000-07217
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
(2) air conditioning units installed one 3 ton and one 2.5-ton heat pump split system. (16) inlets and outlets in addition to a duct for the dryer kitchen and bathroom
Valuation:
N/A
Permit #:
22044-20000-14642
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
(2) air conditioning units installed one 3 ton and one 2.5-ton heat pump split system. (16) inlets and outlets in addition to a duct for the dryer kitchen and bathroom
Valuation:
N/A
Permit #:
22044-20000-14640
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
General hvac. includes garage ventilation. ***new 5-story type iiia 24-unit apartment building over 1 level type ia basement parking garage. affordable density bonus housing project restricting 3 vli units***
Valuation:
N/A
Permit #:
20044-10000-03277
Status:
final
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Per inspectors request supplemental permit. for outlets 36 dryer’s 72 in/outlets 36 kitchen hoods 72 in/outlets 64 bathroom fans 128 in/outlets air conditioning inlet/outlets 144 in/outlets
Valuation:
N/A
Permit #:
21044-90000-28698
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
Supplemental permit 18044-30000-00395 to correct address: from 3063 w. pico blvd. to 3057 w. pico blvd
Valuation:
N/A
Permit #:
18044-20001-00395
Status:
triage
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
General hvac and product conveying garage ventillation for a new 6 story 51 unit apartmnet building
Valuation:
N/A
Permit #:
18044-30000-00395
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A
3045 leeward ave 8. bathroom exhaust fans 4”duct 8 hoods. 6” duct units 101, 102, 103, 104 201, 202, 203, 204 301, 302, 303, 304 we going to install 12 wall heaters 4 on each floor
Valuation:
N/A
Permit #:
21044-90000-16223
Status:
final
Fee:
N/A
Permit Type:
Apartment
Building Type:
N/A

Avalanche Air Inc Reviews

BuildZoom hasn't received any reviews for Avalanche Air Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Avalanche Air Inc
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.