Updated: Aug 20, 2026
Location and Projects
Address
839 Jeffrey Lane, Langhorne, PA, 19047
Use our bidding system to
request a quote
Bartleson Electric Inc
Bartleson Electric Inc, 839 Jeffrey Ln, Langhorne, PA (Employee: Bryan R. Bartleson) holds a Electrical Contractor license and 4 other licenses according to the New Jersey license board.
Their BuildZoom score of 92 ranks in the top 32% of 125,106 Pennsylvania licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Bartleson Electric Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Bartleson Electric Inc Contact Information
Phone Number: (215) 752-7889
Edit
Address: 839 Jeffrey Lane, Langhorne, PA 19047
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Bartleson Electric Inc Langhorne
Quality
92
68th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Bartleson Electric Inc has a BuildZoom score of 92, which places them above 68% of 125,106 contractors in Pennsylvania.
Activity
|
1 project
|
2023 |
Our building permit records indicate that Bartleson Electric Inc has worked on at least
1.0 project over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Pricing
|
1 project
|
$50k-$100k |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
Building Permits by Bartleson Electric Inc
This is a sample of this contractor's permits. Click here to access their complete permit history.
1)temp power and lighting. 2)furnish and install gear and associated equipment as shown on plans. a) 2-panels. b) 1-ats 3) 100a 3-phase 120/208v feeder. 4) branch circuits and devices as shown on plans. a) 40 receptacles. b) 5- switches. c) 12-light fixtures. d) 2-exit signs. 5) equipment tie-ins. a) 1- 30a 3-pole nf safety switch. b) 1- 30a 2-pole safety switch. as per 2017 nec
Valuation:
$69,230
Permit #:
EP-2022-011378
Status:
complete
Fee:
N/A
Permit Type:
Addition and/or a...
Building Type:
N/A
Conversion of existing lunch room into child-care class room as per plan. install and wire complete new the following: 4-20a120v tamperproof duplex receptacles 1-20a120v single-pole switch 2-2x4 lay-in fluorescent light fixtures 1-em light w battery back-up 1-horn/strobe 1-smoke detector all work to be don according to approved drawings. 2016 nfpa-72 and 2017 nec
Valuation:
$7,500
Permit #:
EP-2020-004110
Status:
complete
Fee:
N/A
Permit Type:
Addition and/or a...
Building Type:
N/A
Demolish devices/wiring within partians to be removed. relocate 7-2x4 layin fixtures 1 exit sign 2-3way switches. rework existing 20a 120v lighting circuit to accommodate new open room in new grid. new install 3 new 3lamt8 layin fixtures 3 duplex receptacles utlizing existing 20a120v during demolish per 2008 nec (commerical)
Valuation:
N/A
Permit #:
714852
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Demolish devices/wiring within parts being removed salvage existing hr crts rework alter existing lighting/crts to accomodate open room layout. install 3 gfi 6 duplex receptes 1 exh fan 2 light fixtures 1 em light with bb utilize existing crts made available during demolish as per 2008 nec (east district)
Valuation:
N/A
Permit #:
625209
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations to existing building as per plan. additional: gfi receptacles duplex receptacles 2 single pole switches 3 exhaust fans 19 em light units with battery back up fire alarm system complete. as per 2008 nec. (east district)
Valuation:
N/A
Permit #:
625219
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Demo:7devices/wiring in partitions being removed, salvage existing hr circuits, rework-alter:existing lighting circuits to accomodate open room layout, relocate:3-sp switches at new door openings, , install:3gfi, 6duplex recepts, 1exhaust fan, 1light fixture utilizing existing circuits made available during demolish as per 2008 nec(east district) install 1-strobe into toilet room as p... see more
Valuation:
N/A
Permit #:
574256
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
22 light fixtures 5 em light units 3 em exit light units 6 20a 120 circuits 8-20a 120v gfi receptacles as per nec 2008 remount 3 exsiting horn/strobes & remount 1 existing pull station as per nfpa 72
Valuation:
N/A
Permit #:
786075
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Demolish obsolite device & wiring remove cir back to pnl relocate (13) 2x4 lay in fixtures, (1)20a120v sp sws, install (3)20a120v receptacles, (3)20a 120v sp sws utilizing exist relocated 20a120v cir reinstall 3 smokes into new drop ceiling per 2008 nec (educational facility)
Valuation:
N/A
Permit #:
489363
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Relocate (1)3way switch, (1)2x4 layin lighting fixture and install new 1 single pole switch to operate existing 2x4 light fixture in office per 2008 nec (commercial) east district
Valuation:
N/A
Permit #:
767985
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install & wire complete the following 1-15a 120v ckt 1-20a 120v ckt 1-gfi recpt 1-exhaust fan 3-lighting fixtures & 2-single pole switches as per nec 2008 (sfd)
Valuation:
N/A
Permit #:
507454
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install/wire complete the following: sub-meter, feeder & circuit bkr panel from existing mtr module to tenants storage unit.100a, 120/240v, 1-phase) 2 sp switches 4 lighting outlets/lighting fixtures, 8 duplex receptacles, (3) 20a 120v circuits as per 2005 nec (cc dist)
Valuation:
N/A
Permit #:
264415
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Relocate existing: fire alarm 3 horn strobes 4 smoke detectors 6 exit signs 5 emergency light units 87 2 x 4 lay-in fixtures into new drop ceiling and new walls. install and wire complete new: 50 duplex receptacles 24 3-way switches 17 single pole switches 14 light fixtures 24 tele/data outlets 20 120v 20 amp circuits.(east dist)
Valuation:
N/A
Permit #:
99189
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace utdated circuikt breaker panel relocate 1 horn strobe 2 smoke detectors install and wire complete 54 light fixtures 13 switches 18 recepts 3 exit lights 5 em units 12 - 120v 20 amp circuits 3 tele/data outlets (east district)
Valuation:
N/A
Permit #:
71360
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install/wire following: 20a120v circuit, 1 sngl pole sw & tie-in garbage disposal. 30a240v circuit & tie-in of convection oven 50a240v circuit & tie-in of dishwasher as per 2008 nec (east district)
Valuation:
N/A
Permit #:
270151
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Relocate 6-20a 120v duplex receptacles utilizing existing circuitry to accomodate reconfigured furniture layout
Valuation:
N/A
Permit #:
373301
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install and wire 12 recepts outlets 24 lighting outlets 4 switches 1 exhaust fan 2 base board heat units 3 horn strobes, heat tracer 120/277 volt circuit
Valuation:
N/A
Permit #:
20392
Status:
ACTIVE
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace relocate and install wire systems complete through out building power lighting data telecommunications fire alarm
Valuation:
N/A
Permit #:
36289
Status:
COMPLETED
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install and wire systems complete power lighting data telecommunications fire alarm card access security
Valuation:
N/A
Permit #:
35884
Status:
COMPLETED
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
HIC # 053629
Philadelphia, PA
131
BZ Score
$8.5K
Avg Project
-
Projects
130
BZ Score
$2.2K
Avg Project
-
Projects
149
BZ Score
$10K
Avg Project
-
Projects
Bartleson Electric Inc Reviews
BuildZoom hasn't received any reviews for Bartleson Electric Inc. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Verified License
BuildZoom confirmed this contractor's license
Bartleson Electric Inc License info
Verified License
| HIC # | 34EI00979800 |
| Status | Active |
| State | New Jersey |
| Type | Electrical Contractor |
- BuildZoom verified this license was active as of August 2026.
Verify this license's status for Bartleson Electric Inc at the New Jersey Department of Law & Public Safety.
This is a sample of licensing data; click here to access a complete history.
Verified License
| HIC # | 34EB00979800 |
| Status | Active |
| State | New Jersey |
| Type | Electrical Business Permit |
- BuildZoom verified this license was active as of August 2026.
Verify this license's status for Bartleson Electric Inc at the New Jersey Department of Law & Public Safety.
This is a sample of licensing data; click here to access a complete history.
Verified License
| HIC # | PA048299 |
| Status | Active |
| State | Pennsylvania |
- BuildZoom has not verified this license since February, 2025.
Verify this license's status for Bartleson Electric Inc at the Pennsylvania Office of the Attorney General.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| HIC # | PA048299 |
| Status | Active |
| State | Pennsylvania |
| Type | Complete Electrical Construction And Maintanance Services, Commercial-Industrial-Residential |
- When BuildZoom last verified this license, it had an expiration date of August, 2017. Check the current license status of Bartleson Electric Inc with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | 16791 |
| Status | Inactive |
| City | Philadelphia |
| Type | Electrical Contractor |
- According to the City of Philadelphia Licensed Contractors, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Bartleson Electric Inc at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
92
BuildZoom Score
Insured
| Insurer | Ohio Casualty Company |
| Insured up to | $5,000,000 |
11
Permits
- Building permit records show that Bartleson Electric Inc has worked on 11 permitted projects.
Bartleson Electric Inc Employees
BI
Bartleson Electric Inc
BB
Bryan R. Bartleson