We'll help you find the right contractor.

Share your project details and we'll reach out to Bauer Electrotech so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Is this your business? Claim now >

Location and Projects

Headquarters Address
N8723 Hanson Dr. Holmen, WI. 54636, Holmen, WI, 54636
Local address
517 41ST AVE, Winona, MN, 55987
Use our bidding system to request a quote

Bauer Electrotech Electrician

Bauer Electrotech, 517-41 St Ave, Winona, MN (Owned by: Bauer Electric Inc) holds a Electrical license and 2 other licenses according to the Minnesota license board.

Their BuildZoom score of 106 ranks in the top 7% of 77,973 Minnesota licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Bauer Electrotech, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Bauer Electrotech Services

Start a project today:

Bauer Electrotech Contact Information

Phone: (507) 459-1991 Edit
Headquarters Address: N8723 Hanson Dr. Holmen, WI. 54636, Holmen, WI, 54636
Local Address: 517 41ST AVE, Winona, MN 55987 Edit

Bauer Electrotech Winona

Quality

106
93rd percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Bauer Electrotech has a BuildZoom score of 106, which places them above 93% of 77,973 contractors in Minnesota.

Activity

20 projects
2025
22 projects
2024
20 projects
2023
Our building permit records indicate that Bauer Electrotech has worked on at least 62.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

5 projects
Home Additions
41 projects
Electrical projects
Analyzing permits over the last 4 years shows that Bauer Electrotech mostly works on electrical project and home addition projects.

Pricing

1 project
< $5k
Value Not Public: 41.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Bauer Electrotech

Sort by: Notable Notable | Date Date | Job Value Job Value
Electrical permit
2025-01-06
Install drops for binder room equipment e-room machinery and inkjet relocation. install (10) circuits total. five new circuits and modify two existing circuits in binder room. all fed from panel br2. two new circuits for e-room machines fed from panel br2. two new circuits for inkjet relocation fed from panel next to outlets
Valuation:
N/A
Permit #:
ELE2411-09737
Status:
final
Fee:
$67
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-01-03
Install transformer panelboard and circuits by system #3. 3 circuits. (1) 70a feed from 480v nf panel to transformer new 120/208v panelboard and two 30a circuits from 120/208v panelboard to outlets on wall. all work just east of system #3 on wall
Valuation:
N/A
Permit #:
ELE2412-04289
Status:
final
Fee:
$84
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-01-06
Install outlets for relocated cannon printer and install drops for work stations and equipment in binder room. (8) circuits. two circuits for cannon six circuits for general use and equipment. fed from nearby panelboards
Valuation:
N/A
Permit #:
ELE2411-01578
Status:
final
Fee:
$49
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-02-12
Install power to on demand water heater. (1) circuit 50a 208v 1ph water heater located in sw corner of building 2 - 2nd floor. fed from panel st2-2 ckt #35-37. panel located in ne corner of same building and floor
Valuation:
N/A
Permit #:
ELE2412-08123
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-07-24
Watkins 5-2 seasoning line. install (1) new circuit and drop for machine and extend (2) circuits to new drop location. (3) circuits total. (1) new 50a 240v circuit fed from panel 5n-2b #1 ckt #13-15-17. (2) 120v circuit extensions fed from panel 5n-2b #2 ckt #13 ckt #19
Valuation:
N/A
Permit #:
ELE2507-02735
Status:
final
Fee:
$81
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-06-05
Extend existing circuits to new tv locations in mill area. (4) existing circuits. accel packer tv fed from lunchroom panel ckt #25 pt packer tv fed from mcc1-3 west packer tv fed from mcc1-3 mix plant tv fed from mcc1-8
Valuation:
N/A
Permit #:
ELE2505-10404
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-02-26
Benchmark east building. install circuits and drops for hpe equipment. (17) circuits 1@400a and 16@60a 480v install subpanel. all adjacent to chassis service
Valuation:
N/A
Permit #:
ELE2502-04612
Status:
final
Fee:
$112
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-07-17
Acuity. install (3) outlets for portable air conditioning equipment by powder coating. (3) circuits 30a 240v 1ph. (1) circuit fed from south area panelboard and (2) circuits fed from east area panelboard
Valuation:
N/A
Permit #:
ELE2507-02732
Status:
final
Fee:
$81
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-01-22
Replace existing mcc in malthouse 3. reconnect 2 mcc feed circuits and 25 branch circuits to replacement mcc. all circuits in malthouse 3 electrical room
Valuation:
N/A
Permit #:
ELE2501-04027
Status:
final
Fee:
$155
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-08-08
Wire 2 diverters 2 vegas and 2 pointeks in the mill elevator. 5 circuits total. one circuit to each diverter one circuit to each vega and one looped control circuit to both pointeks. location in mill elevator bin deck. all fed from local automation panel
Valuation:
N/A
Permit #:
ELE2407-11746
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-08-29
Install circuits to new air compressor louvre control panel and outlets. (3) circuits total 1-350a 480v circuit to new air compressor. 2 - 20a 120v circuits to louvre control panel and outlet both adjacent to compressor. 480v circuit fed from service next to compressor and 120v circuits fed from nearby panelboard
Valuation:
N/A
Permit #:
ELE2408-00202
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-02-05
Cpi. install fan circuits. 15 circuits total. (2) circuits at system #2 outlets on wall by press fed from panel lp3. (5) circuits at system #3 (1) feed to new subpanel (4) circuits for fan drops subpanel fed from and next to panel lp5. (8) circuits at system #4 outlets on wall by press fed from panel lp7
Valuation:
N/A
Permit #:
ELE2401-03769
Status:
final
Fee:
$115
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-02-12
Rtp truck shop. (4) total circuits. extend one existing 20a 120v circuit for outlet on wall. install one new 120v 20a circuit for cord drop in center of shop (gfi breaker at panel). install one new 120v 30a circuit and outlet for pressure washer (gfi breaker at panel). install 50a 240v circuit for welder. all circuits fed from panelboard at west wall
Valuation:
N/A
Permit #:
ELE2401-08715
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-06-27
Install new power factor correction bank in elevator electrical room. (1) circuit 500a 480v 3ph. fed from elevator main distribution panelboard
Valuation:
N/A
Permit #:
ELE2506-02496
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-07-11
Wire replacement gas and diesel pumps by east storage building. (2) existing circuits used to feed replacement equipment at fuel pad. circuits fed from east storage building panelboard. work done at fuel pad. no work from pad to building
Valuation:
N/A
Permit #:
ELE2406-10867
Status:
final
Fee:
$71
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-04-15
Alliant castings. wire replacement sand system. (5) circuits total. two new 480v circuits to lampe sand system modify (4) 120v circuits at mezzanine for new lighting outlets and chemical system. all circuits fed from area panelboards (3) 480 volt 3 phase receptacle outlets for temp plasma cutter locations
Valuation:
N/A
Permit #:
ELE2404-03986
Status:
final
Fee:
$55
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-04-21
Sauer healthcare. rework existing circuit and outlets in dining room wall. (1) circuit 120v panel bl1 ckt #16. rough-in required
Valuation:
N/A
Permit #:
ELE2502-04613
Status:
final
Fee:
$71
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2025-10-09
Chs river and rail main shed tripper belt upgrade. modify (2) existing circuits tripper and conveyor. disconnects and connections by motors. wire bin level sensors and laser
Valuation:
N/A
Permit #:
ELE2505-10400
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-04-16
Mcc. install (2) circuits to new air compressor. (1) 480v circuit from mezzanine panelboard to new air compressor and (1) 480v circuit from floor panelboard to new air dryer. all located at east end of building
Valuation:
N/A
Permit #:
ELE2404-03984
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-03-21
Replace leg #2. install larger circuit for leg motor install circuit for distributor fan circuit for distributor and circuit for gate. (4) circuits total two fed from mcc and two fed from 120/240 panel in dump #2
Valuation:
N/A
Permit #:
ELE2403-02658
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A

Similar Contractors See more

License # EL207046EC
113
BZ Score
$5K
Avg Project
-
Projects
License # AM006622
113
BZ Score
$500
Avg Project
-
Projects
License # IR668263
111
BZ Score
$500
Avg Project
-
Projects

Bauer Electrotech Reviews

BuildZoom hasn't received any reviews for Bauer Electrotech. Click here to be alerted when reviews are posted about them.
Please write a review about Bauer Electrotech
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.