Location and Projects

Headquarters Address
, ,
Local address
PO Box 391, Challis, ID, 83226
Use our bidding system to request a quote

Berry Electric

Their BuildZoom score of 0 does not rank in the top 50% of Idaho contractors.

If you are thinking of hiring Berry Electric, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Berry Electric Services

Start a project today:

Berry Electric Contact Information

Phone: (208) 879-3273 Edit
Headquarters Address: , ,
Local Address: PO Box 391, Challis, ID 83226 Edit

Building Permits by Berry Electric

Sort by: Notable Notable | Date Date | Job Value Job Value
Electrical
2007-10-01
; (10/1/2007) f-10/1/07 rd.new 200 amp meter main ok, overhead riser and conductors ok, new 200 amp rated listed manual transfer switch for an emergency portable generator ok, main service disconnect ok, all conductors ok, 2 ground rods ok.final
Valuation:
N/A
Permit #:
ELE-C-663698
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-03-01
; (6/24/2005) 6/24/05 rd. new 480 volt 3 phase service for new pump and pivot.meter, pump panel, pivot disconnect )o, riser and conductors ok, ground rod ok, motor protection and the inside of the equipt can not be inspected due to it being activated and energized
Valuation:
N/A
Permit #:
ELE-C-554657
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2008-05-05
; (5/5/2008) f-5/5/08 rd.new detached garage.no rough in inspection was requested.all wiring installed and complete and covered.100 amp main breaker panel in the garage ok, 4 wire feeders in underground pvc conduit from the existing home to the garage panel ok, ufer ground at the garage panel ok, all ol devices ok, polarity at outlets ok, gfci protection provided where required, in-us... see more
Valuation:
N/A
Permit #:
ELE-C-629264
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-06-07
; (6/7/2007) f-6/7/07 rd.the contractor has installed a new listed photovoltomic system and the sub panel in a small cabin that has no commercial available.the property owner has installed the inside wiring under permit p130525.collector panel ok, panel bonding ok, underground feeder conductors to the service disconnect at the cabin ok, service disconnect ok, inverter ok, feeders to t... see more
Valuation:
N/A
Permit #:
ELE-C-629276
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-03-26
; (3/26/2007) f-3/26/07 rd.new service.new 200 amp single phase meter, riser, and conductors ok, 2 ground rods ok, new listed 200 amp rated manual transfer switch(for a future generator)ok, new 200 amp main breaker rain tight panel on the load side of the transfer switch ok, refeed an existing 100 amp sub panel in the building ok, all ol devices ok, all conductors ok, panel labeled.final
Valuation:
N/A
Permit #:
ELE-C-652984
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-06-04
; (6/4/2007) f-6/4/07 rd.a damaged 480 volt 3 phase pump panel has been changed out(damaged) with a new pump panel.existing meter and riser ok, tie in the existing pump motor ok, new pump panel with a service disconnect ok, all ol and motor protection ok.final
Valuation:
N/A
Permit #:
ELE-C-652978
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-05-07
; (5/7/2007) f-5/7/07 rd.480 volt 3 phase meter and disconnect on a pole ok, overhead riser/conductors ok, 2 ground rods ok, underground feeders to the pivot ok, controller/disconnect at the pivot ok, ground rod at the pivot ok, power supply cord for the towers ok, power supply cord straps on the towers ok, bonding jumpers on the towers ok, all ol and motor protection ok.final
Valuation:
N/A
Permit #:
ELE-C-652975
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-05-07
; (5/7/2007) f-5/7/07 rd.480 volt 3 phase meter and disconnect on a pole ok, overhead riser/conductors ok, 2 ground rods ok, underground feeders to pivot ok, controller/disconnect at pivot ok, ground rod at pivot ok, power supply cord for towers ok, power supply cord straps on the towers ok, bonding jumpers on the towers ok, all ol and motor protection ok.final
Valuation:
N/A
Permit #:
ELE-C-652974
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-05-07
; (5/7/2007) f-5/7/07 rd.480 volt 3 phase meter and disconnect on a pole ok, overhead riser/conductors ok, 2 ground rods ok, underground feeders to the pivot ok, controller/disconnect at the pivot ok, ground rod at the pivot ok, power supple cord for the towers ok, power supply cord straps on the towers ok, bonding jumpers on the towers ok, all ol and motor protection ok.final
Valuation:
N/A
Permit #:
ELE-C-652973
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-05-14
; (5/14/2007) f-5/14/07 rd.the contractor has inspected a 100 amp meter main on a pole that was de-energized by the utility company over a year age in order for the service to be reconnected/metered.the service was energized at the time of my inspection and appears to be ok.final
Valuation:
N/A
Permit #:
ELE-C-652979
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-06-07
; (6/7/2007) f-6/7/07 rd.the contractor has inspected an existing service that had been disconnected in order to reconnect.200 amp meter main on a pole ok, overhead service/conductors ok, ground rod ok, main ol protection ok.the service was energized at the time of my inspection.looks good.final
Valuation:
N/A
Permit #:
ELE-C-652990
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
Po Box 656, Challis, ID, 83226
2007-07-30
; (7/30/2007) f-7/30/07 rd.new 100 amp rain tight panel on a pole at airpot near the self serve fueling station.eisting service at middle fork avation building ok, underground feeders in pvc conduit to the new panel ok, new 100 amp main breaker raintight panel on a pole ok, ground rod at the new sub panel ok, conduit and conductors to a new mercury vapor light on the pole and the new ...
Valuation:
N/A
Permit #:
ELE-C-663682
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-07-30
; (7/30/2007) f-7/30/07 rd.the contractor has replaced a 480 volt 3 phase meter socket on an eisting pole ok, new riser/conductors ok, ground rod ok, eisting pump panel ok, wiring to a rebuilt 10 h.p. 480 volt 3 phase pump ok, all ol protection and motor protection ok, disconnecting means at the eisting pump panel.final
Valuation:
N/A
Permit #:
ELE-C-663690
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-06-28
(6/18/2007) fwhc-6/18/07 rd.inspect wiring for the new service installed by this contractor for a new self service airplane fuel dispensing facility.the contracor has provided a new 250 volt single phase 50 amp circuit from an existing panel in a hanger to a remote mehanical shed.please note that northwest fuel systems has provided all the wiring for the bulk fuel tank and for the fue... see more
Valuation:
N/A
Permit #:
ELE-C-663685
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-12-26
; (12/26/2007) f-12/26/07 rd.signal booster station for phone company equip.100 amp meter main ok, 2 ground rods ok.250 volt 50 amp circuit underground in pvc conduit to phone equipt. ok, all conductors ok, main ol protection ok, panel labeled.final
Valuation:
N/A
Permit #:
ELE-C-675070
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-11-14
; (11/14/2007) f-11/14/07 rd.new 100 amp meter main on a pole ok, 2 ground rods ok, overhead riser/conductors ok, pump panel with disconnect ok, conduit and conductors to the pump motor ok, all ol and motor protection ok, panel labeled.final
Valuation:
N/A
Permit #:
ELE-C-675063
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2015-09-16
No Description Available
Valuation:
N/A
Permit #:
ELE1509-00205
Status:
final
Fee:
$65
Permit Type:
N/A
Building Type:
N/A
Electrical
2007-03-01
; (5/18/2005) 5/18/2005 rd. the pump and pivot are not complete yet.i will check in a week or so. ; (6/24/2005) 6/24/05 rd.the punp and pivot can not be inspected due to both are energized and being operated
Valuation:
N/A
Permit #:
ELE-C-554658
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2015-09-04
(8/22/2014 8:53 am nsm) run 200 a line to mobile home
Valuation:
$500
Permit #:
ELE1408-00385
Status:
final
Fee:
$70
Permit Type:
Contractor
Building Type:
N/A
; (5/9/2007) f-5/9/07 rd.existing meter ok, replace old sub panel with a new 200 amp main breaker sub panel.existing feeders ok, main ol device ok, all branch circuit ol devices ok, panel labeled.final
Valuation:
$800
Permit #:
ELE-C-592643
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A

Similar Contractors See more

License # ELE-C-22663
105
BZ Score
-
Avg Project
-
Projects
License # ELE-J-16636
107
BZ Score
$2K
Avg Project
-
Projects
License # 013676
107
BZ Score
$1.4K
Avg Project
-
Projects

Berry Electric Reviews

BuildZoom hasn't received any reviews for Berry Electric. Click here to be alerted when reviews are posted about them.
Please write a review about Berry Electric
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.