Bob Gilbert Roofing Inc at P O BOX 3766, Winnetka, CA 91396, held a Roofer license (#657919) with the California contractors license board with an expiration date of 11-30-2020. We last verified the license was expired on 05-15-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Commercial reroof as follows:- - - estimated cost of re-roof:12500 - this is a change of roofing material (y/n):no - proposed roofing material:tourch/down - squares (100 sf) being installed:50sq-s - tear off existing (y/n):no - existing layers of roofing:one - new sheathing being installed (y/n):no - high fire hazard zone (y/n):no - - note: all tear-offs require solid sheathing. insta... see more
Tear off (e) roof install 1/2 cdx plywood nail 1 ply 15lb felt install 25 year composition shingles class a 18sqs on pitched roof apply 1 ply 28lb felt install 2 ply torch down modified bitimen built up roof class a 7sqs on flat roof. smoke detectors required
Tear off east 1/2 of (e) roof only install hot mop 2 ply glass ply hot mop 1 ply gaf energy cap built up roof system class a 86sqs. a cool roof labeled and cerified by crrc is required for re-roofing of all non- residential buildings with roofs sloping 16.7% or less per section 149(b) of title 24
Re-roof with class a or b material weighing less than 6 pound per sq. ft. a cool roof labeled and certified by crrc is required for re-roofing of all non-residential buildings with roofs sloping 16.7% or less per section 149(b) of title 24
Re-roof with class a or b material weighing less than 6 pound per sq. ft. a cool roof labeled and certified by crrc is required for re-roofing of all non-residential buildings with roofs sloping 16.7% or less per section 149(b) of title 24
Tear off (e) tile roof install 40lb felt re-install tile. tear off (e) flat roof install b u r class a (nail 1 28lb felt mop 2 ply 11lb felt mop 1 ply capsheet) 4 squares. smoke detectors required. valuation to be verified by field inspector
Repair roof as needed - tear off (e) roof and install approx. 10 squares. of class a torch down modified roofing. replace dry rotted sheathing and rip strips framing. smoke detectors required. units 309 310 and 311. aka 1484 s beverly dr
Tear off (e) roof replace dry rot area with 1/2 cdx plywood (approx. 4 sqs.) install b u r system 1 ply 40 lb felt mop 2 ply 11 lb felt embed #5 granite in asphalt. this is for carport only. 40 squares. smoke detectors required
Re-roof and upgrade framing on (e) single family dwelling and detached garage: tear off (e) cal shake roofing install 1/2 cdx plywood and felt and addition monier slate lifetile (icbo-er2656) and addition bracing and framing per civil engineer's design
Re-roof north center building. only (sherman way side). tear off (e) roof re-roof with class a b u r. 1 ply 40 lb felt mop 2 ply 11 lb. fe.t mop 1 ply gms mop down modified cap sheet. 24sqs. smoke detectors required
Reroof house and garage - tear off existing roof - nail 1/2 cdx plywood nail 1-ply 15lb felt install 25 yr. class a comparable shingles - 32 squares - smoke detector required - valuation to be verified by field inspector
Tear off (e) roof. re-roof with 1/2 cdx plywood apply protex synthethic shakes icob #5492 weighting less than 6lb psf class a material aprox. 24sqs house only. smoke detectors are require
Nail 1 ply 15lb felt install 25 year composition shingles class a over existing 1 layer composition shingles class a on west side of 2nd story only. 20sqs. smoke detectors required
Tear off (e) roof install built up roof system class a. (nail 1 ply 40lb felt mop 3 plys 11lb felt embed #5 granite in asphalt). 64sqs. smoke detectors required. earth quake shutoff valve required
Tear off (e) roof. re-roof with class a bur (1-ply 28lb felt mop 2 plies 11lb felt embed #5 granite in asphalt) aprox. 43sq. smoke detectors are required for valuation over $1000 in residential buildings
Material: comparable shingle class a - no. of squares: 22 squares. - tear of existing (y/n): yes - existing no. of layers: two - new sheathing (y/n): yes - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: built up roof - no. of squares: 15 - tear of existing (y/n): y - existing no. of layers: 3 - new sheathing (y/n): n - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Bob Gilbert Roofing Inc at the California Contractors State License Board.