Bowen James D Electrician

Bowen James D, 324 Cotton Dr, Waco, TX (Owned by: Bowen Landscape Services) holds a Electrical Contractor license and 52 other licenses according to the Hewitt license board.

Their BuildZoom score of 111 ranks in the top 4% of 222,249 Texas licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Bowen James D, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Bowen James D Services

Start a project today:

Bowen James D Contact Information

Phone: (972) 829-2110 Edit
Address: 324 Cotton Dr, Waco, TX 76712 Edit

Bowen James D Waco

Quality

111
96th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Bowen James D has a BuildZoom score of 111, which places them above 96% of 222,249 contractors in Texas.

Activity

24 projects
2025
78 projects
2024
110 projects
2023
Our building permit records indicate that Bowen James D has worked on at least 212.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

27 projects
Home Additions
6 projects
Commercial Renovations
5 projects
Fences
4 projects
New Constructions
171 projects
Electrical projects
Analyzing permits over the last 4 years shows that Bowen James D mostly works on electrical project and home addition projects.

Pricing

11 projects
< $5k
6 projects
$5k-$20k
4 projects
$20k-$50k
1 project
$50k-$100k
1 project
$100k-$250k
2 projects
$1mil+
Value Not Public: 190.0 projects
The typical size of their permits is approximately $7,000. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Bowen James D

Sort by: Notable Notable | Date Date | Job Value Job Value
Residential (elec)
2024-10-11
**200amps; 30-110's; 5-220's; tfinal** based on el-i-053219-2023 make repairs to electrical work done by previous contractor. *original permit #23-02532-elec** rewire home and rebuild 200a service anticipate approximately (30) 1p circuits and (5) 2p circuits rough temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
24-00521-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2024-08-02
****permit split fees original paid on 22-02540-elec- this permit to cover: 1-800amps 11-110 24-220, 1-3phase, tfinal*****dottie oaks mitchell is gc 22-00247-bldc moving the following from 22-02540-elec at 1024 austin because building permits were split. 800a service (11) 1p (24) 2p (1) 3p circuits ufer was already inspected on 22-0540-elec and should be moved here will need undergrou... see more
Valuation:
N/A
Permit #:
23-01306-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2024-01-26
**350amps; 38-110's; 8-220's; 2-3phase; tpole; tfinal** mary ave sports complex robison is gc 350amp service (38) 1p (8) 2p (2) 3p circuits will need temp pole slab rough ufer ceiling rough temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
23-01214-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2024-04-17
Merrick mitchell is gc 21-002359-bldc bowen taking over for mes on this project. **88-110 4-220 105 - 3phase 2 - 4000as 2 - 5000as temp final** swbd 1- 5000a service (12) 3p swbd 2- 5000a service (10) 3p swbd 3- 4000a service (20) 3p swbd 4- 4000a service (14) 3p other subpanels- (88) 1p (4) 2p (49) 3p will need ufer underground slab rough wall rough ceiling rough temp final and final... see more
Valuation:
N/A
Permit #:
23-00509-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2023-03-23
**1-800 amp 66-110 7-220 14- 3-phase t-final t-pole** watershed car wash barsh is gc 800amp service (66) 1p (7) 2p (14) 3p circuits will need temp pole slab rough slab ground/ufer underground wall rough ceiling rough temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
22-01012-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Repairs & alterations
2022-10-24
Allen samuels interior renovations to existing space including electrical modifications. no mechanical. or plumbing. included in scope. 2018 ibc occupancy group b construction type ii-b not sprinklered. no change to existing occupant load
Valuation:
$150,000
Permit #:
21-00703-BLDC
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alternative power source
2023-09-27
Update service meter and riser to 200a. install 26kw natural gas generator with a manual interlock switch. addition (1) 1p circuit for battery charger. will need underground temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
23-01289-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Residential (elec)
2023-03-14
**150 amps; 3-110's; 2-220's; tfinal** service upgrade 150amp service and (1) 2p circuit to feed new garage subpanel rewire garage with (3) 1p (1) 2p circuits will need temp final and and final inspections temp power letter attached
Valuation:
N/A
Permit #:
23-00327-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building Permit
2025-08-20
Addition to an existing single-family single-story wood framed residence on crawlspace foundation. addition includes master suite and ancillary spaces and outdoor patio cover
Valuation:
N/A
Permit #:
2025-566
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2024-04-29
Mi casita service repair replace interior components of subpanel if parts can be found. repair line side of main disconnect due to terminal corrosion. temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
24-00186-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2023-03-30
Reinspect because inspection expired before the city applied for service antique street light at pivovar change out pedestal to correct voltage. plans attached. final inspection only - permit#22-03004-elec
Valuation:
N/A
Permit #:
23-00476-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2023-03-22
***1-200 16-120, 1-240, 1-3phrase, tfinal***suite 130 stretch zone 200a service (16) 1p (1) 2p (1) 3p circuits will need wall rough ceiling rough temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
23-00106-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2023-09-20
Antique street light by pivovar. originally inspected on 20-01857 with 120/208 pedestal. was later changed to 480v pedestal because oncor's pole was 480v and inspected on 22-03004. now must be changed back to 120/208 per oncor so they can connect to different pole. final inspection only
Valuation:
N/A
Permit #:
23-01856-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Residential (elec)
2023-06-26
**150amp; 12-110's; 4-220's; tfinal for mother-in-law ste main house is on permit #22-02445-elec** unit b grassroots has building permit wire new small apartment with 150amp service (12) 1p (4) 2p will need rough temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
22-02446-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Residential (elec)
2023-06-23
**200amp 16-110's; 4-220's tpole tfinal - for main house mother-in-law ste on permit #22-02446-elec** unit a grassroots has building permit wire new house with 200amp service (16) 1p (4) 2p will need temp pole ufer slab rough rough temp final and final inspections temp power letter attached
Valuation:
N/A
Permit #:
22-02445-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2022-06-16
Repairs per commercial check. final inspection only. ***5/10/2022 jkq *electrical power for water heater is not installed as per nec requirements. *wiring for exit sign at rear of building is not installed as per nec requirements. *circuit breaker openings in panel box are not capped/plugged as per nec requirements. *(drinking fountain required but not there yet)installation of new el... see more
Valuation:
N/A
Permit #:
22-01242-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2022-08-17
Clean up services at 1611 and 1613 and combine into one. both spaces had been combined together at one point but each space is on it's own meter. there will be no new loads. new service riser/meter and main disconnects will be on back side of building 1611. temp power letter and diagram attached
Valuation:
N/A
Permit #:
22-00308-ELEC
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alternative power source
2022-05-13
Update 200a service installing 20kw generator 200a ats adding (2) 120v circuits. will need temp final and final inspections. will be occupied and down on day of temp final. temp power letter attached. riser diagram fault current site plan etc attached
Valuation:
N/A
Permit #:
22-00020-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2022-01-21
Suite 1000 sorrells pulled building permit chatfield is electrician for most of the work. we were hired to check the ul listing and power supply on the class 2 lighting and controls which is outside of chatfields scope. final inspection only. low voltage lighting counts and specs attached for inspector
Valuation:
N/A
Permit #:
21-03083-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial (elec)
2022-01-24
Suite 3200 sorrells pulled building permit chatfield is electrician for most of the work. we were hired to check the ul listing and power supply on the class 2 lighting and controls which is outside of chatfields scope. final inspection only. low voltage lighting counts and specs attached for inspector
Valuation:
N/A
Permit #:
21-03082-ELEC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 7502
110
BZ Score
-
Avg Project
-
Projects
License # 42141-01
114
BZ Score
-
Avg Project
-
Projects
License # 42274
111
BZ Score
-
Avg Project
-
Projects

Bowen James D Reviews

BuildZoom hasn't received any reviews for Bowen James D. Click here to be alerted when reviews are posted about them.
Please write a review about Bowen James D
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.