Address
10869 ALCOTT CT., Denver, CO, 80234
Use our bidding system to request a quote

Busch Mechanical Inc

Busch Mechanical Inc, 10869 Alcott Ct, Wesmtinster, CO (Owned by: Busch Cory) holds a H & V B license and 9 other licenses according to the Denver license board.

Their BuildZoom score of 95 ranks in the top 22% of 55,949 Colorado licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Busch Mechanical Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Busch Mechanical Inc Services

Start a project today:

Busch Mechanical Inc Contact Information

Phone: (720) 545-4080 Edit
Address: 10869 ALCOTT CT., Wesmtinster, CO 80234 Edit

Busch Mechanical Inc Wesmtinster

Quality

95
78th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Busch Mechanical Inc has a BuildZoom score of 95, which places them above 78% of 55,949 contractors in Colorado.

Activity

1 project
2025
1 project
2024
Our building permit records indicate that Busch Mechanical Inc has worked on at least 2.0 projects over the past 2 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Pricing

1 project
$20k-$50k
Value Not Public: 1.0 project
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Busch Mechanical Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Mechanical permit
2025-09-25
Install 3-zone mitsubishi heat pump system in areas designated in scope according to plans. install dryer exhuast vent. install panasonic erv system according to plans. install two panasonic whisperquiet exhaust fans in mechanical and laundry rooms. all exhuasts are to be terminated outside. inlet for erv will contain birdscreen on outside wall termination. outlet for erv will termina... see more
Valuation:
$21,950
Permit #:
2025-MECH-0006416
Status:
issued
Fee:
$195
Permit Type:
N/A
Building Type:
Single family res...
Hvac solar water heater wood burning
2024-04-30
Remove existing heating furnace and associated ductwork including gas piping. (this was installed without a permit) city of boulder is asking this to be removed. (location is the rusty melon restaurant) suite # 380
Valuation:
N/A
Permit #:
MEC2024-00472
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Accessory structure new construction
2021-08-27
1200 sf pole frame detached garage on dirt - includes electric - 4% ok 03/31/2021 - amend to install heater and gas line - sc-- approved (jg)
Valuation:
$30,600
Permit #:
ASN20-0262
Status:
final
Fee:
$975
Permit Type:
N/A
Building Type:
N/A
Hvac solar water heater wood burning
2024-04-12
Remove an un-permitted furnace and associated ductwork in back room at rusty melon restaurant. suite # 380
Valuation:
N/A
Permit #:
MEC2023-01547
Status:
canceled
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
B-add/alt hvac commercial
2020-08-03
Install 3/4 hp 115 volt exhaust fan on existing curb on roof. installed previously.need to get rid of fumes in garage area form fertilizer
Valuation:
$2,963
Permit #:
BP-20-01686
Status:
complete
Fee:
$168
Permit Type:
N/A
Building Type:
Commercial/indust...
Hvac solar water heater wood burning
2018-09-25
Installation of a replacement 12 eer 10.0 ton rooftop air conditioning system. installation per manufacturer's specifications
Valuation:
N/A
Permit #:
MEC2018-01008
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace furnace unit 304
Valuation:
$3,144
Permit #:
19107057 00000MP
Status:
complete
Fee:
N/A
Permit Type:
Other
Building Type:
Residential
No Description Available
Valuation:
N/A
Permit #:
19107057 00000MP
Status:
complete
Fee:
N/A
Permit Type:
Other
Building Type:
N/A
Removal of nine existing rtus -- replacement units to be installed on same location on existing curbs -- substantailly the same sizes and weights. eight 5-ton units to have a seer rating that exceeeds 13.0, one 7.5 ton unit to have a seer rating that exceeds 11.0.
Valuation:
$0
Permit #:
PMT2011-03438
Status:
Completed
Fee:
N/A
Permit Type:
NonResidential
Building Type:
Office - Technica...
Hvac solar water heater wood burning
2011-10-26
Removal of nine existing rtus -- replacement units to be installed on same location on existing curbs -- substantailly the same sizes and weights. eight 5-ton units to have a seer rating that exceeeds 13.0 one 7.5 ton unit to have a seer rating that exceeds 11.0
Valuation:
N/A
Permit #:
PMT2011-03438-MEC
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install single sided s-facing non illuminated double poled freestanding sign of max. 25 overall height 96 s.f feet total for directional signs mounted and 50+ setback
Valuation:
$46,000
Permit #:
B1306031
Status:
Issued Full
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removal of 10 rtus on this structure -- install ten replacement units in same locations. see unit specific technical information for seer/eer rating requirements.
Valuation:
$0
Permit #:
PMT2011-05020
Status:
Issued
Fee:
N/A
Permit Type:
NonResidential
Building Type:
Office - Technica...
Mechanical
2010-11-09
Installation of snow melt equipment in north parking lot and adjacent alley . boilers installed though separate permit, separate right-of-way permit required prior to work in alley.
Valuation:
$0
Permit #:
PMT2010-04945
Status:
Completed
Fee:
N/A
Permit Type:
NonResidential
Building Type:
Religious Assembl...
Removal of thirteen rtus on this structure -- install thirteen replacement units. see unit specific technical data relating to seer/eer in inspection packet.
Valuation:
$0
Permit #:
PMT2011-05018
Status:
Completed
Fee:
N/A
Permit Type:
NonResidential
Building Type:
Office - Technica...
Hvac solar water heater wood burning
2017-10-31
Permit for the replacement of condensing unit for trinity lutheran for cooling the sanctuary
Valuation:
N/A
Permit #:
PMT2017-03238-MEC
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commercial
2017-11-15
Replace existing rooftop unit like for like
Valuation:
N/A
Permit #:
BLDG17-6576
Status:
final
Fee:
$330
Permit Type:
Mechanical
Building Type:
N/A
Permit for the replacement of condensing unit for trinity lutheran for cooling the sanctuary
Valuation:
N/A
Permit #:
PMT2017-03238
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
Religious assembly
Mechanical
2016-04-18
Replace 2 rtus like-for-like, non-structural.
Valuation:
$0
Permit #:
PMT2016-01674
Status:
Issued
Fee:
N/A
Permit Type:
NonResidential
Building Type:
Commercial/Retail...
Mechanical
2016-03-31
Replace like-for-like (non-structural) 4 rtus
Valuation:
$0
Permit #:
PMT2016-01378
Status:
Issued
Fee:
N/A
Permit Type:
NonResidential
Building Type:
Commercial/Retail...
Hvac solar water heater wood burning
2012-09-18
Removal of thirteen rtus on this structure -- install thirteen replacement units. see unit specific technical data relating to seer/eer in inspection packet
Valuation:
N/A
Permit #:
PMT2011-05018-MEC
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # CR24-0149
129
BZ Score
$4.5K
Avg Project
-
Projects
License # CL-006595-2025
128
BZ Score
$8.7K
Avg Project
-
Projects
License # CR25-0822
134
BZ Score
$6.7K
Avg Project
-
Projects

Busch Mechanical Inc Reviews

BuildZoom hasn't received any reviews for Busch Mechanical Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Busch Mechanical Inc
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.