California Express Plbg Inc at 3107 SCOTT RD, Burbank, CA 91504, held a Plumber license (#834142) with the California contractors license board with an expiration date of 03-13-2010. We last verified the license was inactive on 05-03-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
Complete plumbing for a 6-unit 3-story apartment building. water supply pressures = 94 133 psi 1-1/2 inch water meter rp backflow preventer is not required. pipe friction loss = 11.4 psi per 100ft. low pressure gas system with less than 10 gas outlets no plan check is required. a separate inspection for gas system is required
Supplemental permit to collect fees for __1______ (number) additional inspection(s) per inspection notice # _________or date_08/01/2007_____. this permit does not authorize any additional work or extend the expiration date of the original permit and 1 hose bibb 1 backflow device 5 lawn sprinkler devices
Supplemental permit to collect fees for permit number 04042-30000-24289. additional inspection per inspection correction notice #u64566 dated 6-27-06. this permit does not authorize any additional work or extend the expiration date of the original permit
Install eighty four (84) fuel outlets twenty eight (28) earthquake actuated gas shut off valves twenty (20) area drains one (1) water service for irrigation twenty eight (28) water heaters and vents and two (2) sewer connections in a 4 story 28 unit apartments
Install new hot and cold water distribution waste and vent rainwater drains sump pumps and sub-surface drainage systems in a 25-unit 3-story apartment building. twenty five (25) 1 water meter shall be installed on potable water supply line serving each dwelling unit. backflow protection is not required
Install new plumbing fixtures in a 14-unit 4-story over 2 level parking garage apartment building. fifteen (15) 1 water meters (one (1) for house fourteen (14) for apartment units) shall be installed on incoming potable water supply lines. backflow preventers are not required
Supplemental permit for 7 earthquake shut off valves. supplemental permit to collect fees for permit number 07042-10000-21078. additional inspection per inspection correction notice dated 03/02/09. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit for gas outlets and to collect fees for permit number 07042-10000-21078. additional inspection per inspection correction notice dated 5-14-08. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for ___1_____ (number) additional inspection(s) per inspection notice # _________or date__11/01/2007____. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for ___1_____ (number) additional inspection(s) per inspection notice # _________or date11/13/07______. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for ____1____ (number) additional inspection(s) per inspection notice # _________or date__04/26/07____. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for permit number 06042-20000-08261. additional inspection per inspection correction notice dated. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to permit # 05042-30000-23983 to collect fees for 1 of additional inspection(s) per inspection correction notice this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for one additional inspection per inspection correction notice #64566 dated 06/27/06. this permit does not authorize any additional work or extend the expiration date of the original permit
Install new plumbing fixtures in a 10-unit 2-story apartment building. plumbing plan check for water only. a 2 water meter shall be installed on incoming potable water supply line. backflow protection is not required
Supplemental permit to collect fees for 1 additional inspection per inspection correction notice dated 4-9-07. this permit does not authorize any additional work or extend the expiration date of the original permit
Plan check for sump pump emergency drain trench drain & foundation drain system. note: storm drain planter drain & area drain system with stormceptor (see susmp approval) requires a separate plan check/permit
Plan check for water sump pump(ed, td sub surface) & gravity rain water system. 2 water meter. no back flow required. pipe sizing is based on 3 psi/100. water pressures are 86/49 psi. 4 story apartment. bldg97 units)
Supplemental permit to collect fees for (1) additional inspection(s) per inspector dated ( ). this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to permit #07042-30000-04508 to collect fees for 1 additional inspection. this permit does not authorize any additional work or extend the expiration date of the original permit
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for California Express Plbg Inc at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.