Updated: Sep 19, 2025
Location and Projects
Address
75-17 COOPER AVE 2ND FL, Glendale, NY, 11385
Use our bidding system to
request a quote
Cannon Mechanical Inc
Cannon Mechanical Inc, 75-17 Cooper Ave, Glendale, NY (Owned by: Patrick J Gallagher) holds a Gc Safety Registration license according to the New York license board.
Their BuildZoom score of 98 ranks in the top 16% of 77,888 New York licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Cannon Mechanical Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Cannon Mechanical Inc Contact Information
Phone Number: (718) 326-7500
Edit
Address: 75-17 COOPER AVE 2ND FL, Glendale, NY 11385
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Cannon Mechanical Inc Glendale
Quality
98
84th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Cannon Mechanical Inc has a BuildZoom score of 98, which places them above 84% of 77,888 contractors in New York.
Activity
|
7 projects
|
2025 |
|
3 projects
|
2024 |
|
5 projects
|
2023 |
Our building permit records indicate that Cannon Mechanical Inc has worked on at least
15.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
14 projects
|
Mechanical projects |
|
8 projects
|
HVAC projects |
Analyzing permits over the last 4 years shows that Cannon Mechanical Inc mostly works on
mechanical project
and hvac project
projects.
Pricing
|
1 project
|
$5k-$20k |
|
2 projects
|
$20k-$50k |
|
3 projects
|
$50k-$100k |
|
2 projects
|
$100k-$250k |
|
1 project
|
$500k-$1mil |
|
6 projects
|
$1mil+ |
The typical size of their permits is approximately $394,860. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
Building Permits by Cannon Mechanical Inc
This is a sample of this contractor's permits. Click here to access their complete permit history.
Modifications to hvac equipment and installation of emergency generator as per plans. no change to use egress or occupancy
Valuation:
$2,886,750
Permit #:
M00848230-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Herewith filing mechanical modifications for albert einstein college of medicine - van etten non-production lab surgical skills lab conf. rooms. no change in use egress or occupancy
Valuation:
$1,400,000
Permit #:
X01061001-S1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Modification of hvac equipment piping and ductwork to accommodate the make-up air project as per plans. no change to use egress or occupancy
Valuation:
$1,313,671
Permit #:
M01231237-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Modifications to hvac equipment as per plans. no change to use egress or occupancy
Valuation:
$2,104,413
Permit #:
M00850426-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Modification of hvac equipment and ductwork to accommodate the replacement of ahu as per plans. no change to use egress or occupancy
Valuation:
$1,280,000
Permit #:
M00872250-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Upgrade air handling unit including new ductwork outside air dampers steam heat coils replace motor and starter; provide temporary ahu during construction. all work as per plans. work includes no change to zoning use egress occupancy
Valuation:
$580,000
Permit #:
M00486875-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Filing herewith drawings indicating modification of the mechanical system on the 2nd floor. no change in use egress or occupancy under this application
Valuation:
$184,943
Permit #:
M00960467-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical and ductwork work filed in conjunction with office renovation. no change to use egress or occupancy
Valuation:
$209,720
Permit #:
M00855236-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removal of chillers and related piping. install new chillers related piping and ductwork on the 49th floor as per plans filed herewith. no change in use occupancy or egress
Valuation:
$2,499,994
Permit #:
M00725163-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical modifications taking place on 4th and 5th floor as per plans filed herewith. no change in use egress or occupancy
Valuation:
$50,003
Permit #:
M01117227-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement & installation of chiller and associated systems in boiler room as per plans filed herewith. no change in use egress or occupancy. no exterior work. no interior work visible from exterior
Valuation:
$2,400,000
Permit #:
X00636487-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical systems installation in conjunction with interior renovation of retail space. no change in egress use or occupancy
Valuation:
$1,999,998
Permit #:
M00436448-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removal of chiller and associated systems in boiler room as per plans filed herewith. no change in use egress or occupancy. no exterior work. no interior work visible from exterior
Valuation:
$700,000
Permit #:
X00634894-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical work filed in conjunction with the commercial space in cellar as per plan
Valuation:
$61,000
Permit #:
B01001478-S2-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical modification/removals on part of the basement as indicated on the attached plans. there is no change in use egress or occupancy
Valuation:
$274,000
Permit #:
X00695512-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Modification to mechanical system as per plans filed herewith
Valuation:
$23,300
Permit #:
M01215684-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Reconnecting fume hood exhaust in new wet lab and providing ventilation and exhaust in new gas storage room
Valuation:
$32,499
Permit #:
X00836275-S1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Renovating existing lab with replacement of new heat pumps diffusers and ductwork
Valuation:
$55,998
Permit #:
X00881161-S3-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Herewith filing modifications to the existing mechanical system. no change in use egress or occupancy
Valuation:
$1,555,700
Permit #:
X00202894-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Renovating existing lab with replacement of new heat pumps diffusers and ductwork
Valuation:
$19,742
Permit #:
X00836344-S1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
135
BZ Score
$37.3K
Avg Project
-
Projects
License # 028375
New York, NY
122
BZ Score
$99.8K
Avg Project
-
Projects
122
BZ Score
$91K
Avg Project
-
Projects
Cannon Mechanical Inc Reviews
BuildZoom hasn't received any reviews for Cannon Mechanical Inc. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an HVAC pro in your area today
We'll search our vast network of HVAC Pros and connect
you with one that meets your needs today.
Verified License
BuildZoom confirmed this contractor's license
Cannon Mechanical Inc License info
Verified License
| License # | 615339 |
| Status | Active |
| State | New York |
| Type | Gc Safety Registration |
- BuildZoom has not verified this license since June, 2025.
Verify this license's status for Cannon Mechanical Inc at the New York City Department of Buildings.
This is a sample of licensing data; click here to access a complete history.
98
BuildZoom Score
Insured
| Insurer | Colony Insurance Company |
Insured
| Workers Comp Provider | Nysif |
25
Permits
- Building permit records show that Cannon Mechanical Inc has worked on 25 permitted projects.
Cannon Mechanical Inc Employees
PG
Patrick J Gallagher
Owner