Caplow Mechanical Inc at 5 HAMDEN PARK DR, Hamden, CT 06511, held a HVAC/Mechanical Contractor license (#MEC.0001157) with the Connecticut contractors license board with an expiration date of 08-31-2022. We last verified the license was expired on 08-21-2023.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 12,093 Connecticut contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
Demolish cut cap and make safe all waste vent water and gas pipe in kitchen area dishwasher room demolish all old equipment install new kitchen/breakroom sink tie into existing; bathrooms 105 106 125 & 126 replace toilets and sinks in each using existing rough
56 prospect st. second floor north side. two areas of work. area 1 remove 3 heads install 9 new vic concealed heads with white plates on existing arm overs area 2 remove 2 heads install 9 new vic concealed heads with white plates on existing arm overs. all other existing areas remain as is
Per plans: pd100 pd101 pd102 pd103 p200 p201 p202 p203 p204 date: 08/03/17 6-new toilets 6-new sinks 2-s/s sinks 3-janitor sinks 1 water cooler 1-floor drain 1-gas water heater gas piping mixing valve back flow waste and vent piping hot and cold water piping. r dillon inspector: r dillon 203-946-8038
**ssa 7th floor** per drawing demolish existing sink install new rough water waste vent at new location. new sink faucet electric water heat water to coffeemaker and water dispenser. toilet sink drinking fountain. r dillon inspector: r dillon 203-946-8048
Install two sinks eye wash mixing valve waste vent water air lines new emergency shower mixing vent hot & cold water one new doulbe bayt s/s sink waste vent water *spl 11, 20-20a labs* - m rispoli inspector: m rispoli 203-946-8038
Demolish existing sink install new rough water waste vent at new locations. new sinks faucets electric water heater water to coffeemakers. per drawing. r dillon inspector: r dillon 203-946-8038
Domestic water piping waste piping and gas piping including water closets kitchen sinks bath/shower gas fired hot water heaters and washer connection (as per plan). r velez inspector: r velez 203-946-7595
*office of development 8th 9th 10th 11th floor.* relocate heads per new ceiling drawings. head to be moved in same room as required. r dillon inspector: r dillon 203-946-8038
New installation of kitchen sink lavatory toilet shower trench drain oil separator floor drain electric hot water heater gas piping and air piping. m rispoli inspector: m rispoli 203-946-8038
Disconnect three sinks three toilets reconnect two toilets and two sinks on existing rough. install new waste vent and water piping to sk-1 kitchen sink. m rispoli contractor: 203-671-1530
Disconnect three sinks cut cap waste and water in the wall. rough in new sink waste vent and water set one of the removed sink in this location. 1 lav - r velez inspector: r velez 203-946-7595
Per drawing demolish existing sink install new rough water waste vent at new location new sink faucset electric water heater water to coffeemaker and water dispenser. r dillon inspector: r dillon 203-946-8038
*room 109a* per drawing p1.1 dated: 07/14/2017 install waste and vent to fume hood install tw to new eye wash. cw ca and n2 line to fume hood. r dillon inspector: r dillon 203-946-8038 certificate of approval
Replace existing piping in south tunnel install floor drain and slop sink basement req underground waste venting and water piping relocation pipe for ahu basement. m rispoli contractor: 203-671-1530
Complete plumbing for two new bathrooms and two pantries waste vent hot & cold water fixtures 2nd and 3rd floor first niagra bank. m rispoli contractor: 203-248-9858
Install waste water vac air to two dental chairs waste vent and water to two sinks. m rispoli inspector: m rispoli 203-946-8038 certificate of approval
Demolish existing sinks piping - new di water line wash mechanical vack water heater wastvent water one sink 1st floor - r velez inspector: r velez 203-946-7595