Don't wait to get an Electrician

We make finding an electrician fast, easy, and commitment-free.

Call now (623) 259-4111
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >
C

Location and Projects

Address
241 Harvest Run Dr, Idaho Falls, ID, 83404
Use our bidding system to request a quote

Chapmans Electrical Contracting Inc

Their BuildZoom score of 0 does not rank in the top 50% of Idaho contractors.

If you are thinking of hiring Chapmans Electrical Contracting Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Chapmans Electrical Contracting Inc Services

Start a project today:

Chapmans Electrical Contracting Inc Contact Information

Phone: (208) 522-3639 Edit
Address: 241 Harvest Run Dr, Idaho Falls, ID 83404 Edit

Building Permits by Chapmans Electrical Contracting Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
; (9/6/2007) 1 jrny, 1 appr. ; (9/11/2007) rq (9/11/2007) rip, rc-mainfloor, unfinished basement, att-t-verbal with les about water softner rough in in front of basement panel and 3 ft of clearance.foamed before inspection ; (11/7/2007) rq (11/7/2007) att-t-bad gfci in garage. watersoftner that is roughed in in front of panel in basement is not installed yet but after installation of ... see more
Valuation:
N/A
Permit #:
ELE-C-662184
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(12/27/2007) rq (12/27/2007) rip, ufer, rc, att-t-verbal with les 300.4a2 above panel over s.e. cable; (4/7/2008) rq, na, locked ; (4/8/2008) na-locked ; (4/9/2008) f, air conditioning rough only, dishwasher not installed
Valuation:
N/A
Permit #:
ELE-C-664061
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(8/22/2007) rq (8/22/2007) rip, rc-mainfloor, unfinished basement, ufer, att-t-verbal with les about nailplates over s.e. cable outside wall and nm pulled against metal truss gusset; (10/17/2007) rq (10/17/2007) f, t
Valuation:
N/A
Permit #:
ELE-C-662181
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(9/12/2007) rq (9/12/2007) rip, rc-mainfloor, unfinished basement, ufer, ; (10/5/2007) g-ground resistance tester indicates 10.4 omhs to ground on ufer ; (12/14/2007) f, air conditioning rough only (12/14/2007) rq
Valuation:
N/A
Permit #:
ELE-C-662189
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(11/7/2006) rq (11/7/2006) rt-service nipple not properly bonded, using grounding locknut without a locknut behind it, rc-mainfloor, basement unfinished ; (11/8/2006) rq (11/8/2006) ri, remove red tag -double locknuts installed; (1/3/2007) rq (1/3/2007) f, unfin. basement, air conditioning rough in only
Valuation:
N/A
Permit #:
ELE-C-631621
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(3/9/2007) rq (3/9/2007) rip, rc-mainfloor, unfinished basement, ufer in garage wall; (5/23/2007) rq (5/23/2007) att-t-panel fillers, master bathroom gfci not working ; (5/24/2007) ri, att-t-panel fillers still not installed ; (5/30/2007) ri, f, panel fillers installed
Valuation:
N/A
Permit #:
ELE-C-652773
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
; (8/3/2007) rip rc ufer ; (1/8/2008) 3 appr. 1 cleaning up 1 installing low voltage 1 standing outside smoking. let them khow not to do any line voltage work until jrny got back ; (2/29/2008) rq (2/29/2008) att-t-master bathroom tv recep not gfci finish labeling basement panel ; (3/17/2008) ri f bathroom gfci installed
Valuation:
N/A
Permit #:
ELE-C-662193
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(10/15/2007) rq (10/15/2007) in process of having urathane foam sprayed inside will return later; (12/10/2007) na, locked ; (12/11/2007) f, att-this house was insulated and sheetrocked before inspection, not approved, everything appears to check out on final, unfinished basement
Valuation:
N/A
Permit #:
ELE-C-655148
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(10/26/2007) rq (10/26/2007) rip, rc-mainfloor, unfinished basement, ufer, att-foamed before inspection, verbal about nailplates over s.e. cable above basement panel; (12/17/2007) ri, f (12/17/2007) rq (12/17/2007) att-t-outside recep at air conditioning rough in not installed
Valuation:
N/A
Permit #:
ELE-C-675591
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(2/29/2008) rq (2/29/2008) att-insulated before inspection-not approved, unfinished basement, ufer; (4/10/2008) rq ; (4/15/2008) f, air conditioning rough only, dishwasher and furnace damper and floor recep not installed yet(verbal with doug farnsworth)
Valuation:
N/A
Permit #:
ELE-C-679864
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(9/30/2008) rip, ufer, rc-mainfloor, unfinished basement; (11/18/2008) att-t-422.31 on built in ovens and cooktop, blank cover on 2 jboxes in basement need blank covers hot wires inside, 210.8a gfci basement recep. ; (11/25/2008) nh, left doorhanger, follow up on verbal corrections ; (11/26/2008) ri, f, verbal corrections completed
Valuation:
N/A
Permit #:
ELE-C-686153
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(12/22/2006) rq (12/22/2006) att-netted and partially insulated, 2 rods not insalled yet, cn-no ufer, panel & service inspected; (2/2/2007) att-t-living room receps 2 open neutrals, rear recep not energized ; (2/5/2007) ri , corrections not completed yet
Valuation:
N/A
Permit #:
ELE-C-646621
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(8/12/2008) rq ; (8/13/2008) att-t-kitchen recep not gfci, jetted tub receps not installed, label basement panel, air conditioning max ocp 20a not 30a. x-ref: c-679206 for rough in; (8/20/2008) ri, fwhc ; (9/10/2008) f
Valuation:
N/A
Permit #:
ELE-C-686149
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(3/16/2007) rq (3/16/2007) so, cn-no ufer, att-t-insulated before inspection, not approved; (5/23/2007) rq (5/23/2007) f, air conditioning rough in only, home has never had rough in inspection but everything appears to be correct
Valuation:
N/A
Permit #:
ELE-C-652775
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
Electrical
2007-10-18
; (9/6/2007) rq (9/6/2007) rip, rc, ufer, foamed before inspection ; (10/18/2007) rq (10/18/2007) f, air conditioning rough only, d.w. not installed
Valuation:
N/A
Permit #:
ELE-C-662186
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(12/5/2007) rip, ufer, rc-mainfloor, unfinished basement; (4/7/2008) rq, att-t-210.8a7 laundry room, not approved, air conditioning rough in only, dishwasher not installed ; (4/10/2008) ri, f, gfci installed 210.8a7
Valuation:
N/A
Permit #:
ELE-C-675585
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(8/12/2008) rq (8/12/2008) att-t-install receps under jetted tub, x ref: c-679210 for rough in; (8/20/2008) ri, fwhc, receps installed under jetted tub with gfci protection ; (9/10/2008) f
Valuation:
N/A
Permit #:
ELE-C-686148
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
; (12/10/2007) na, locked ; (12/17/2007) ri, f (12/17/2007) att-no power kitchen receps or living room air conditioning rough in only
Valuation:
N/A
Permit #:
ELE-C-655141
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(1/16/2008) 1 jrny, 2 appr. ; (1/22/2008) rq (1/22/2008) rip, ufer, rc-mainfloors-unfinished basement; (4/10/2008) rq ; (4/15/2008) f, homeowners already living in home, random inspection
Valuation:
N/A
Permit #:
ELE-C-664066
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A
(10/15/2007) rq (10/15/2007) rip, rc-mainfloor, unfinished basement, 2 rods, cn-no ufer; (12/12/2007) na, locked ; (12/13/2007) f, air conditioning rough only, cn-yellow 422.31b
Valuation:
N/A
Permit #:
ELE-C-655149
Status:
final
Fee:
N/A
Permit Type:
Contractor
Building Type:
N/A

Similar Contractors See more

License # RCE-1519
110
BZ Score
$5.3K
Avg Project
-
Projects
License # ELE-C-38860
108
BZ Score
$10.2K
Avg Project
-
Projects
License # ELE-C-12881
112
BZ Score
$1K
Avg Project
-
Projects

Chapmans Electrical Contracting Inc Reviews

BuildZoom hasn't received any reviews for Chapmans Electrical Contracting Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Chapmans Electrical Contracting Inc
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.