We'll help you find the right contractor.

Share your project details and we'll reach out to Charles Edwin Harris Jr so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >

Location and Projects

Address
Hughesville, MD, 20637
Use our bidding system to request a quote

Charles Edwin Harris Jr Electrician

Charles Edwin Harris Jr, Hughesville, MD (Employee: Patrick Graham Pleasants) holds a Electricians license and 1 other license according to the Maryland license board.

Their BuildZoom score of 101 ranks in the top 12% of 58,058 Maryland licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Charles Edwin Harris Jr, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Charles Edwin Harris Jr Services

Start a project today:

Charles Edwin Harris Jr Contact Information

Phone: (410) 242-3200 Edit

Building Permits by Charles Edwin Harris Jr

Sort by: Notable Notable | Date Date | Job Value Job Value
Electrical permit - residential
2023-12-07
Heavy up the existing 300 amp service to a 500 amp service. [ the existing 100 amp and 200 amp panels to remain ] adding a new 200 amp main panel beside the existing mains [ 500 amp total ] and replacing the existing dual lug power company meter base with a new ct cabinet-meter # trg020941355
Valuation:
N/A
Permit #:
ELEC-231302
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - commercial
2023-06-14
Heavy up the existing 300 amp main underground service from 300 amps to 500 amps [ the existing 100 amp and 200 amp main panels to remain]. installing a new 200 amp main breaker panel and replacing the existing dual lug power company meter base with a ct cabinet. meter number - 1n6034546527
Valuation:
N/A
Permit #:
ELEC-231297
Status:
canceled
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2023-02-03
Install a new 150 amp disconnect and sub-panel beside the existing sub-panel. install a new dual lug meter base in place of the existing single lug meter base. meter 1n6034001274. 1/30/2023 - wiring install and outlet beside new panel wire for wall thermostat for electric heater
Valuation:
N/A
Permit #:
ELEC-222443
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2023-08-03
Remove existing 200 amp main breaker panel and replace. install a new 150 amp main disconnect. remove the existing 200 amp single lug meter base and replace dual lug meter base. [ 350 amp heavy up ] meter #1n6034499861
Valuation:
N/A
Permit #:
ELEC-230245
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2023-04-04
Wire for and install a dedicated 30 amp 240 volt circuit a 60 amp 240 volt circuit and a 60 amp sub-panel to the utility room and a 60 amp weatherproof sub-panel beside the power company meter for future use
Valuation:
N/A
Permit #:
ELEC-230661
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - commercial
2024-10-16
Replace an existing 200 amp main breaker panel with a new 200 amp main breaker panel [ the 200 amp main panel has a damaged breaker buss bar and is part of an existing 350 amp main underground service ]
Valuation:
N/A
Permit #:
ELEC-240824
Status:
expired
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2025-04-15
Wire and install 2-ceiling fan/light fixtures 7 lights 8 receptacles 4 switches and wire for and connect 2 - 5 kw mini split hvac systems
Valuation:
N/A
Permit #:
ELEC-240668
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2022-12-16
Install a new 150 amp main breaker panel beside the existing 200 amp main breaker panel [ the existing 200 amp main breaker panel and existing dual lug power company meter base to remain ] meter no. nyg020777354
Valuation:
N/A
Permit #:
ELEC-221394
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2022-01-24
Replace an existing 200 amp interior trailer panel with a new 200 amp indoor trailer panel. *no meter on site. (the existing power company meter base main weatherproof disconnect and service cables to remain)
Valuation:
N/A
Permit #:
ELEC-212009
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2023-04-04
Install a new 200 amp main breaker panel in place of the existing 150 amp main panel. replace the existing power company meter base. meter#1n6034193947
Valuation:
N/A
Permit #:
ELEC-230516
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2021-12-16
Heavy up the existing 200 amp main service to 350 amp - install a new 200 amp weatherproof disconnect on the existing 200 amp main panel. replace the single lug meter base with a new dual lug meter base install a new weatherproof 150 amp main panel beside the new meter base a new 150 amp sub-panel. wire for and install 1 switch 1 light and 1 receptacle. meter 1n6034193167
Valuation:
N/A
Permit #:
ELEC-211885
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2023-06-22
Replace existing 200 amp meter base and heavy up to addition 150 amp main panel for accessory building-meter #1n6034504719
Valuation:
N/A
Permit #:
ELEC-230904
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2021-06-17
Install a new 200 amp main breaker panel in the basement utility room install a new service entrance cable relocate the existing feeds to the new main panel from an adjacent bathroom. meter# nyg020777414
Valuation:
N/A
Permit #:
ELEC-210958
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2021-07-06
Install a new 150 amp main breaker panel beside the existing 200 amp main breaker panel [ the existing 200 amp main breaker panel is to remain ] install a new dual lug meter base. meter 1n6034193189
Valuation:
N/A
Permit #:
ELEC-210125
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2023-03-21
Wire for and install 1- 20 amp clothes washer circuit and 1- 30 amp dryer circuit in an unfinished basement
Valuation:
N/A
Permit #:
ELEC-230257
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2022-03-08
Wire for and connect a hot tub with a 60 amp ground fault protected 120 240 volt circuit from an existing weatherproof sub-panel (pool-220004)
Valuation:
N/A
Permit #:
ELEC-220316
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2020-11-24
Install a new 200 amp single lug meter base with a new 200 amp weatherproof disconnect convert an existing 200 amp main panel into a sub-panel [ overhead service the work had been started by another contractor ] wire for and connect an electric stove and an electric dryer each with a 4 wire circuit
Valuation:
N/A
Permit #:
ELEC-202094
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2021-06-29
Install a new 200 amp main breaker panel and service entrance cable in place of the existing 100 amp main breaker panel and service entrance cable [ underground service ] meter 1n6034550683
Valuation:
N/A
Permit #:
ELEC-201103
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - commercial
2022-05-26
Building permit # 210290 wire for and install 30 receptacles 29 lights 12 exit emergency lights 9 switches and 10 cat 6 cable prewires
Valuation:
N/A
Permit #:
ELEC-220363
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit - residential
2021-10-25
Heavy up from 200 amp to 350 amp [underground service the existing 200 amp main breaker panel is to remain]. wire for and install 1 - 20 amp dedicated microwave receptacle
Valuation:
N/A
Permit #:
ELEC-210785
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 10812
120
BZ Score
$42K
Avg Project
-
Projects
License # 10730
120
BZ Score
$500
Avg Project
-
Projects
License # 14720
132
BZ Score
$2K
Avg Project
-
Projects

Charles Edwin Harris Jr Reviews

BuildZoom hasn't received any reviews for Charles Edwin Harris Jr. Click here to be alerted when reviews are posted about them.
Please write a review about Charles Edwin Harris Jr
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.