Location and Projects
Address
6905 Buckhorn Ct, Loveland, CO, 80538
Use our bidding system to
request a quote
Cole Excavating Inc
Cole Excavating Inc at 6905 Buckhorn Ct, Loveland, CO 80538, has a BuildZoom score of 90 and ranks in the top 53% of 55,949 Colorado contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
Cole Excavating Inc Contact Information
Address: 6905 Buckhorn Ct, Loveland, CO 80538
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Major repair permit issued to replace failing system. install system per engineer’s design; van horn engineering project #2020-12-08. final inspection required by design engineer and larimer county. * abandoned tank must be either completely removed or if left in place pumped of its contents tank bottom must be broken top and sides must be collapsed and remaining space filled to natur... see more
Valuation:
N/A
Permit #:
20-HSEP0253
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
*system design is based on site evaluation and soils report provided by van horn engineering project #1989-11-13. *for a 3 bedroom home; install a minimum 1 250 gallon 3-compartment tank and 36 – 4’ standard chambers in a bed. install chambers 1’ below grade on the uphill side. * an audible and visual alarm indicating a high water condition must be provided. the pump must be connected... see more
Valuation:
N/A
Permit #:
19-HSEP0032
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Standard system design based on soils report provided by trail ridge consulting engineers project #5051 cr 59. *for a 3-bedroom home and a 2-bedroom accessory living area; install tank(s) with a minimum 2 000-gallon holding capacity. a single 2 000 gallon 2-compartment tank or a 1000 gallon 2-com partment tank to serve each dwelling meets this requirement. soil treatment area to consi... see more
Valuation:
N/A
Permit #:
20-HSEP0250
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install system per engineer’s design; all service septic project #435e. final inspection must be made by design engineer and larimer county. *for a 2 bedroom home: install a minimum 1000 gallon 2 compartment tank followed by a 500 gallon dosing tank. effluent filter must be placed on outlet of the second compartment of the 2 compartment tank or pump must be placed in a screened vault.... see more
Valuation:
N/A
Permit #:
18-HSEP0205
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Major repair permit issued to replace failing soil treatment area. design based on average percolation rate of 20mpi noted in soils report from van horn engineering project #01-03-14. *for 3 bedrooms or short term rental that sleeps 8; install a minimum 1 200 square feet rock & pipe bed or 70 – 4’ standard chambers in a bed. install chambers or gravel no deeper than 36” below existing... see more
Valuation:
N/A
Permit #:
18-HSEP0293
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
*permit issued for installation of vault to serve single family residence. the property’s close proximity to a stream as well as the steep grades on the property are prohibitive for the installation of a standard owts. vaults are not recommended for use with full-time dwellings. *install a minimum 1 250 gallon vault with indicator to signal when vault reaches 75% capacity. install one... see more
Valuation:
$0
Permit #:
17-HSEP0243
Status:
final
Fee:
$0
Permit Type:
N/A
Building Type:
N/A
Standard system design based on soils report provided by cornerstone engineering project #438004. *for 4 bedrooms; install a minimum 1250 gallon 2-compartment tank and 1 048 square feet rock & pipe or 62 – 4 standard chambers in a bed or 51 – 4 standard chambers in trenches separated by 4 of undisturbed soil. install bottom of chambers or gravel no deeper than 48 below existing grade ... see more
Valuation:
N/A
Permit #:
18-HSEP0059
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
*major repair permit issued to replace leach field and pump tank. install system per engineer’s design; cds corporation project #16-8485. final inspection required by design engineer and larimer county. *system design for maximum of 1995 gallons per day for a 45 seat restaurant with paper service and banquet/event venue with up to 266 guests. restaurant and banquet/events may not oper... see more
Valuation:
N/A
Permit #:
17-HSEP0049
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Permit issued to replace a vault which was damaged in the 2013 flood. the property's proximity to the big thompson river is prohibitive for the installation of a standard owts. an easement agreement must be written and recorded with the larimer county clerk and recorder allowing the use of lot 15 for the installation and maintenance of a vault which will serve lots 13 and 14. *existin... see more
Valuation:
N/A
Permit #:
17-HSEP0279
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install system per engineer’s design; van horn engineering project #2017-0505. final inspection required by design engineer and larimer county. * for 2 bedroom single family residence: install a minimum 300 square foot pipe and gravel soil treatment area per design. treatment area must be overexcavated to a minimum depth of 6’ below existing grade. place 3’ of imported astm c33 sand f... see more
Valuation:
N/A
Permit #:
17-HSEP0273
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
*engineer design: install system per engineer's design; van horn engineering and surveying project no. 21-01-29. engineer has designed a pressure dosed system to a 3 foot sand filter. *septic tank: for a 2 bedroom home with intermittent 550 gallons usage install a minimum 2000 gallon 2-compartment tank. effluent filter must be placed on outlet of second compartment of the tank. provid... see more
Valuation:
N/A
Permit #:
21-HSEP0286
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install system per engineer’s design; van horn engineering project #2020-09-02. final inspection required by design engineer and larimer county. *for a 2-bedroom home; install a minimum of 18 – 4’ standard chambers in 2 trenches with 9 chambers in each trench. install chambers no deeper than 12” below grade on the uphill side. provide 4’ of undisturbed soil between trenches. *hang 2 s... see more
Valuation:
N/A
Permit #:
20-HSEP0232
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
*permit issued for replacement of existing septic tank. *for 1 bedrooms; install a minimum 1000 gallon 2-compartment tank with watertight risers and lids to grade. *replace any damaged piping at tank inlet/outlet with a minimum of 4 sdr 35 pvc. *existing tank must be pumped and crushed in place including tank bottom or completely removed
Valuation:
N/A
Permit #:
22-HSEP0108
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Owts to support caretakers’ cabin the furthest building to the west. standard system design based on soils report provided by trail ridge consulting engineers project # 8160 hw 7. *for a 4 bedroom home; install a minimum 1 250 gallon 2-compartment tank and one of the following options: 788 square feet rock & pipe bed or 46 – 4’ standard chambers in a bed or 38 – 4’ standard chambers i... see more
Valuation:
N/A
Permit #:
20-HSEP0105
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Permit issued for repair of vault damaged in the september 2013 flood. install a minimum 1250 gallon vault with indicator (float or alarm) to signal when tank has reached 75% capacity. install a traffic rated lid and risers if vault will be installed in driveway or parking area
Valuation:
N/A
Permit #:
15-H0008
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Major repair permit issued to replace failing soil treatment area. *existing tank may be used if found in good condition. install water tight risers to grade on tank lids. *for 2 bedrooms; install a minimum 720 square feet rock & pipe bed or 42 – 4’ standard chamber bed or 35 – 4’ standard chambers in trenches separated by 4’ of undisturbed soil. install chambers or gravel at a depth ... see more
Valuation:
N/A
Permit #:
18-HSEP0143
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Permit issued for repair of system damaged in september 2013 flood. install system per engineer's design; church owc llc. job #: b1046 - revised 12-10-2014. install a minimum of 14 - 4 (48 x 34") chambers in soil treatment area and a 1000 gallon two compartment tank. existing loamy sand to be used for construction of soil treatment area remove rocks >6 encountered during excavation. a... see more
Valuation:
N/A
Permit #:
14-H0260
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
*permit issued for repair of vault damaged in september 2013 flooding. *install a minimum 1250 gallon vault with an alarm or float to indicate when tank has reachedh 75% capacity. *maintain 50 setback from vault to river and any wells or water cisterns
Valuation:
N/A
Permit #:
15-H0132
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
*permit issued for repair of system damaged in september 2013 flood. *install system per engineer's design; van horn engineering project no.l 2012-04-26. final inspection must be made by larimer county and design engineer. *install a minimum 1000 gallon/2-compartment tank and 450 sq ft in soil treatment area. provide an inspection port installed into the soil below the gravel at the e... see more
Valuation:
N/A
Permit #:
15-H0200
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
**refund issued 11/7/16 should have been a major repair $923 per cjm/hy** *permit issued for repair of system damaged in september 2013 flood. replacement system to be installed on south side of property outside of flood way. *install a minimum 1000 gallon 2-compartment tank and 53 - 4 standard chambers in a bed or 44 - 4 standard chambers in trenches separated by 6 of undisturbed soi... see more
Valuation:
N/A
Permit #:
15-H0229
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
License # CL4378
Arvada, CO
114
BZ Score
$20K
Avg Project
-
Projects
License # LIC-00995374
Dacono, CO
116
BZ Score
$600K
Avg Project
-
Projects
License # CR21-0130
Keenesburg, CO
115
BZ Score
$800
Avg Project
-
Projects
Cole Excavating Inc Reviews
BuildZoom hasn't received any reviews for Cole Excavating Inc. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Hiring a contractor?
Cole Excavating Inc License info
License Not Required
| Status | Not Required |
- BuildZoom verified in August, 2018 that this contractor does not need a license to be a contractor in Colorado.
This is a sample of licensing data; click here to access a complete history.
90
BuildZoom Score
25
Permits
- Building permit records show that Cole Excavating Inc has worked on 25 permitted projects.