Consumer Roofing Center at 7438 VARNA AVENUE, North Hollywood, CA 91605, held a Roofer license (#616284) with the California contractors license board with an expiration date of 09-28-2005. We last verified the license was revoked on 04-01-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Material: comparable shingle 40 yr class a - no. of squares: 22 squares. - tear of existing (y/n): yes - existing no. of layers: wood and comparable - new sheathing (y/n): yes - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. - - single family dwelling -
Material: comparable shingle - no. of squares: 14 - tear of existing (y/n): y - existing no. of layers:2 - new sheathing (y/n): y - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: comparable shingle class a portion: back of the house - no. of squares: 9 - tear of existing (y/n): y - existing no. of layers: 3 - new sheathing (y/n): n - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: comparable shingle 25 yr class a - no. of squares: 15 squares. - tear of existing (y/n): yes - existing no. of layers: 5 - new sheathing (y/n): no - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: class a gerard metal tiles. - no. of squares: 63 squares. - tear of existing (y/n): y. complete tear off. - existing no. of layers: - new sheathing (y/n): y. install 1/2 cdx plywood. - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: comparable shingle (house) - no. of squares: 15 - tear of existing (y/n): y - existing no. of layers: 3 - new sheathing (y/n): y - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: comparable shingle class a - no. of squares:4 squares. - tear of existing (y/n): yes - existing no. of layers: three - new sheathing (y/n): no - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. - - - garage
Material: comparable shingle class a - no. of squares:19 squares. - tear of existing (y/n): yes - existing no. of layers: three - new sheathing (y/n): no - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. - - - single family dwelling
Material:class a light weight tile. - no. of squares:9 squares - tear of existing (y/n):y - existing no. of layers:2 - new sheathing (y/n):n - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. - (tore off two layers of comparable and installed light weight tile.)
Material: comparable shingle 40 yr class a - no. of squares: 6 squares. - tear of existing (y/n): yes - existing no. of layers: wood and comparable - new sheathing (y/n): yes - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. - - garage -
Material:class a - no. of squares:16 squares - tear of existing (y/n):y - existing no. of layers:3 - new sheathing (y/n):n - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: comparable shingle & built up roof(house only) class a - no. of squares: 31 - tear of existing (y/n): y - existing no. of layers: 2 - new sheathing (y/n): y - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: comparable. shingle class a - no. of squares:3 squares. - tear of existing (y/n): yes - existing no. of layers: three - new sheathing (y/n): yes - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: comparable. shingle class a - no. of squares:21 squares. - tear of existing (y/n): yes - existing no. of layers: three - new sheathing (y/n): yes - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material: 30 year comparable shingle class a - no. of squares: 40 - tear of existing (y/n): y - existing no. of layers: wood and comparable - new sheathing (y/n): y - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material:comp shingle - no. of squares:8 - tear of existing (y/n):y - existing no. of layers:1 - new sheathing (y/n):n - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material:comp shingles - no. of squares:10 - tear of existing (y/n):y - existing no. of layers:1 - new sheathing (y/n):n - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Tear off (e) wood shake roof. re-roo with 1/2 cdx plywood apply gaf product install 25yrs fiberglass shingles class a material aprox. 12sq. (rear side of the building only flat roof area is not included) smoke detectors are required
Valuation:
N/A
Permit #:
00016-20000-14779
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
Residential alteration or addition - plan check-permit
Cross street: villa bonita/del rio rd. tb: 1271 f6 activity code: 42rp14 42r114 description of work: single family dwelling re-roof: remove shake install 2200 s.f. monier dura-lite tile. 1/7/05 - renew permit for 1 year - new expiration date is 1/7/06...amc
Tear off (e) roof re-roof with gerard metal shingles class a and built up roof system class a. icbo# ner 423. 33sqs. house and detached garage. smoke detectors required. earth quake shutoff valve required
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Consumer Roofing Center at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.