Don't wait to get an Electrician

We make finding an electrician fast, easy, and commitment-free.

Call now (623) 259-4111
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >

Location and Projects

Address
9144 CYPRESS DR. S, Ft Myers, FL, 33967
Use our bidding system to request a quote

Coup Aaron Thomas Electrician

Coup Aaron Thomas, 9144 Cypress Dr S, Ft Myers, FL (Employee: Coup, Aaron Thomas) holds a Certified Electrical Contractor license and 3 other licenses according to the Florida license board.

Their BuildZoom score of 111 ranks in the top 4% of 191,428 Florida licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Coup Aaron Thomas, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Coup Aaron Thomas Services

Start a project today:

Coup Aaron Thomas Contact Information

Phone: (239) 228-6581 Edit
Address: 9144 CYPRESS DR. S, Ft Myers, FL 33967 Edit

Coup Aaron Thomas Ft Myers

Quality

111
96th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Coup Aaron Thomas has a BuildZoom score of 111, which places them above 96% of 191,428 contractors in Florida.

Activity

62 projects
2025
71 projects
2024
64 projects
2023
Our building permit records indicate that Coup Aaron Thomas has worked on at least 197.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

30 projects
Home Additions
3 projects
Commercial Renovations
187 projects
Electrical projects
Analyzing permits over the last 4 years shows that Coup Aaron Thomas mostly works on electrical project and home addition projects.

Pricing

104 projects
< $5k
46 projects
$5k-$20k
14 projects
$20k-$50k
6 projects
$50k-$100k
2 projects
$100k-$250k
Value Not Public: 33.0 projects
The typical size of their permits is approximately $2,400. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Coup Aaron Thomas

Sort by: Notable Notable | Date Date | Job Value Job Value
Panel and service change like for like per customer and scope of work`
Valuation:
$8,875
Permit #:
ELE2025-01437
Status:
complete
Fee:
$129
Permit Type:
N/A
Building Type:
N/A
- install square d qo 200-amp weather-rated combination meter and main disconnect panel to intercept lcec wiring - install surge protection in outdoor panel as required by code - install new 2 service mast to penetrate rooftop - install new weather head and roof boot on mast as to prevent any water intrusion - install new 200-amp weather-rated wiring from exterior main panel through m... see more
Valuation:
$6,773
Permit #:
ELE2025-01318
Status:
complete
Fee:
$79
Permit Type:
N/A
Building Type:
N/A
Electrical - residential (1 and 2 family residences)
2025-05-28
> panel - remove existing federal pacific panel. - replace existing 200-amp main lug interior panel with 200-amp square d qo 42 space main lug panel. - install all new square d breakers and reconnect all wiring existing wiring to remain. - label panel with label maker. - install breaker style 25 kva rated surge protector for code. > disconnect - install square d qo 200 amp disconnect ... see more
Valuation:
$7,332
Permit #:
BLDTR25-002894
Status:
complete
Fee:
$100
Permit Type:
N/A
Building Type:
N/A
Permit c: storage 4 units 456-459 - use existing feed (remove existing conduit and install new) to refeed existing carport storage units and light poles. - install junction box on unit #459 exterior to tie into existing wiring feeding pole lights. - install 2 gang box in each owner's storage unit for 1 gfci protected outlet and a switch to control light. - install 1 junction box with ... see more
Valuation:
$6,718
Permit #:
ELE2025-01004
Status:
complete
Fee:
$79
Permit Type:
N/A
Building Type:
N/A
Permit b: storage 4 units 473-476 - use existing feed (remove existing conduit and install new) to refeed existing carport storage units and light poles. - install junction box on unit #476 exterior to tie into existing wiring feeding pole lights. - install 2 gang box in each owner's storage unit for 1 gfci protected outlet and a switch to control light. - install 1 junction box with ... see more
Valuation:
$6,718
Permit #:
ELE2025-01002
Status:
complete
Fee:
$79
Permit Type:
N/A
Building Type:
N/A
-remove existing electrical panel missing dead front and install 60 amp rated non fusible disconnect to feed hot tub disconnect. remove existing broken disconnect. -install 50 of schedule 80 conduit required for installations from ground level to 10 to existing disconnect and repull existing wire. 1806 leamington ln
Valuation:
N/A
Permit #:
PREL20240627016
Status:
final
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
Residential one a...
Electrical - residential (1 and 2 family residences)
2025-06-13
Main panel - remove and unwire existing 200-amp main breaker ite panel. - install new 200-amp 42 space main breaker square d qo panel in garage - replace all existing circuit breakers and install new breakers in accordance to wiring size. - after installation correctly label all circuits within main panel using label maker. - repair existing chewed up wiring above main panel in wiring... see more
Valuation:
$4,906
Permit #:
BLDTR25-002724
Status:
complete
Fee:
$100
Permit Type:
N/A
Building Type:
N/A
**emergency** replace existing 200 amp meter base due to arc flash and damaged meter base. upgrading grounding to code. this includes 2 copper ground rods and grounding bridge for communication grounds. ground wire will be sleeved in pvc conduit and secured to side of house and land in new meter can. ground wire will be direct burial in between the 2 ground rods. 1610 e mount vernon l... see more
Valuation:
N/A
Permit #:
PREL20240937083
Status:
final
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
Residential one a...
Commercial alteration to primary structure (includes buildout; excludes additional square footage)
2025-04-24
Partial interior demolition and reconfigure existing areas
Valuation:
N/A
Permit #:
COM2024-01459
Status:
complete
Fee:
$3,283
Permit Type:
Industrial building
Building Type:
Vacant
- replace existing 200-amp main breaker interior panel with 200-amp square d qo 42 space main lug panel. - install all new square d breakers and reconnect all wiring - label panel with label maker - install square d qo 200 amp disconnect on exterior of home next to existing meter socket and install conduit and wiring from disconnect to new electrical panel - update existing grounding ... see more
Valuation:
$2,400
Permit #:
ELE2025-00710
Status:
complete
Fee:
$79
Permit Type:
N/A
Building Type:
N/A
- replace existing 125 amp main lug 20 space challenger panel and install 125 amp main lug 24-30 space square d qo panel. - install breaker style surge protection to code. - replace all devices with customer supplied devices 134 cypress way e 1 (unit) naples
Valuation:
N/A
Permit #:
PREL20250206885
Status:
filed
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
Residential one a...
This work is being done for the hoa association. street lights -remove existing street light disconnect and install customer supplied disconnects and circuit breakers -reconnect exisitng conduits and tie in wiring -supply and install photocell at each new disconnect location -supply and install 10 kva surge suppressor on each new disconnect -replace photocells on existing disconnects ... see more
Valuation:
$4,515
Permit #:
ELE2025-00448
Status:
triage
Fee:
$79
Permit Type:
N/A
Building Type:
N/A
Remove/replace 100amp disconnect remove/replace conduit install main breaker addition 40amp circuit to disconnect install 50amp circuit to square d qo 8 space weatherproof sub panel install conduit from existing panel to new location
Valuation:
$2,000
Permit #:
ELE2022-05335-R01
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removing existing panel and devices damaged from hurricanes replacing w new. installing 4 new 20amp circuits w wr gfi outlets & bubble covers per each location in drawings. 220 goodland dr goodland hurricane milton
Valuation:
N/A
Permit #:
PREL20241248771
Status:
final
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
Business
Electrical
2025-02-05
Install 50 amp dedicated circuit from existing pool panel to sauna location. install approximately 50 of 3/4 schedule 80 pvc to install circuit for sauna. install gfci protection for sauna. 3363 cerrito ct naples
Valuation:
N/A
Permit #:
PREL20241144217
Status:
final
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
Residential one a...
Remove existing 200-amp panel and install new 200-amp panel like for like. remove existing meter socket and 200-amp disconnect and replace with new 200-amp meter main combo. install 30-50amp generator inlet. install whole home surge protection. install 50-amp rv outlet. for storage
Valuation:
$8,108
Permit #:
ELE2025-03789
Status:
complete
Fee:
$79
Permit Type:
N/A
Building Type:
N/A
Upstairs electrical panel: - remove existing 200-amp bryant panel and replace with new square d qo panel like for like. - install breaker style surge suppressor per code. electrical panel: - remove existing siemens panel and replace with new square d qo panel like for like. - install breaker style surge suppressor per code. - update grounding per code
Valuation:
$6,731
Permit #:
ELE2025-02950
Status:
complete
Fee:
$79
Permit Type:
N/A
Building Type:
N/A
Addition the following description to the existing permit: remove corroded dual gang meter housing (required by lee county inspector). remove neighbor's existing disconnect. remove wooden structure the service is currently built on. install concrete post to mount new service (fpl requirement). install new single gang meter housing. connect existing fpl service to new meter. reconnect ... see more
Valuation:
N/A
Permit #:
ELE2025-03388-R01
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building - building (r) - restoration
2025-06-21
Hurricane ian restoration: **atf** misc plumbing misc ele seal floors 24 drywall/insulation baseboards/trim lower cabinets paint
Valuation:
$140,208
Permit #:
RES25-120735-BOS
Status:
final
Fee:
$1,629
Permit Type:
N/A
Building Type:
N/A
Install 100-amp service for irrigation control panel
Valuation:
$6,962
Permit #:
ELE2024-04462
Status:
complete
Fee:
$79
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

123
BZ Score
$125K
Avg Project
-
Projects
License # EC13007936
129
BZ Score
$50K
Avg Project
-
Projects
130
BZ Score
$2.4K
Avg Project
-
Projects

Coup Aaron Thomas Reviews

BuildZoom hasn't received any reviews for Coup Aaron Thomas. Click here to be alerted when reviews are posted about them.
Please write a review about Coup Aaron Thomas
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.