Crown Castle Construction

With 25 years of experience, Crown Castle works with communities throughout Utah to build and maintain communications infrastructure. The company specializes in designing, constructing, and upgrading wireless towers, small cell networks, and fiber solutions to expand network coverage and capacity for wireless carriers, businesses, and government clients. Crown Castle’s portfolio includes projects that support mobile connectivity and data transmission in both metropolitan and suburban areas. Services span site acquisition, engineering, regulatory compliance, construction, and ongoing maintenance, enabling efficient deployment of wireless and broadband networks. The company’s teams manage all phases of infrastructure projects, from planning and permitting to installation and integration. Crown Castle focuses on building solutions that meet the evolving needs of carriers and enterprises seeking reliable voice and data connectivity.

Crown Castle Contact Information

Phone: (205) 909-2024 Edit

Crown Castle

Quality

105
92nd percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Crown Castle has a BuildZoom score of 105, which places them above 92% of 74,376 contractors in Utah.

Activity

17 projects
2025
4 projects
2024
5 projects
2023
Our building permit records indicate that Crown Castle has worked on at least 26.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Pricing

4 projects
$5k-$20k
1 project
$50k-$100k
Value Not Public: 16.0 projects
The typical size of their permits is approximately $17,500. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Crown Castle

Sort by: Notable Notable | Date Date | Job Value Job Value
Building permit
2025-03-14
The purpose of this project is to enhance broadband connectivity and capacity to the existing eligible wireless facility. tower scope of work: remove (3) amphenol - bxa-70040/8cf-edin antennas. remove (2) commscopet-001 - ava5-50 coaxial cables. install (4) cbng - 39ghz vectastar nr gnb antennas. install (1) 6x12 hybrid cable. install (1) 12 ovp surge supressor. ground scope of work: ... see more
Valuation:
$15,000
Permit #:
BLD25-0402
Status:
issued
Fee:
$380
Permit Type:
N/A
Building Type:
N/A
Commercial tenant improvement/remodel
2023-04-26
T-mobile is adding a temporary mw dish to the to be built crown castle tower at elk ridge middle school the mw will be present until fiber utility is brought to the tower. tower scope of work: • install (1) commscope vhlp1-23 1’ • install (1) ceragon rfu-d • install (1) ½” coax
Valuation:
$20,000
Permit #:
PRCR202202383
Status:
issued
Fee:
$503
Permit Type:
Alteration/remodel
Building Type:
N/A
Building permit
2025-10-09
The purpose of this project is to propose an antenna modification on an existing wireless site · remove (6) antennas · relocate (3) antennas · relocate (6) rrhs · install (6) antennas
Valuation:
$15,000
Permit #:
BLD25-0560
Status:
complete
Fee:
$380
Permit Type:
N/A
Building Type:
N/A
Commercial permit
2022-10-10
Remove 1 antenna per sector (total of 3) remove 2 tma per sector (total of 6) replace 1 horizontal pipe per sector (total of e) install 2 stacked antenna/rrh per sector (total of 6) install 1 surge suppressor 3 6awg dc trunks & 1 24-pair fiber trunk
Valuation:
$65,000
Permit #:
PMT22-15136
Status:
expired
Fee:
$936
Permit Type:
Other commercial
Building Type:
N/A
Commercial permit
2023-09-11
The requested modifications to the tower include: • removal of three (3) rrh per sector (9) total • removal of two (2) tma per sector (6) total • removal of one (1) antenna per sector (3) total on position (3) • replacement of one (1) dc6 w dc9 surge suppressor • installation of one (1) tri rrh mount (3) total • installation of two (2) stacked integrated antennas/rrhs per sector (6) t... see more
Valuation:
$20,000
Permit #:
PMT22-17356
Status:
final
Fee:
$915
Permit Type:
Other commercial
Building Type:
N/A
Building permit
2025-01-06
Addition (1) mw dish antenna and ancillary equipment as per plans for an existing carrier on an existing wireless communication facility
Valuation:
$65,000
Permit #:
BLD24-1294
Status:
expired
Fee:
$1,113
Permit Type:
N/A
Building Type:
N/A
Commercial permit
2023-06-29
Addition of ground equipment as per plans for an existing carrier at an existing wireless communication facility. note - adm22-00617 was submitted for planning administrative review. planning determined review was not needed due to the minor scope of work. new single phase electric meter
Valuation:
$15,000
Permit #:
PMT22-12431
Status:
final
Fee:
$468
Permit Type:
Macro cell site
Building Type:
N/A
Building permit
2025-03-20
An antenna modification on an existing wireless site. remove (6) antennas install (6) antennas
Valuation:
$15,000
Permit #:
BLD25-0420
Status:
issued
Fee:
$496
Permit Type:
N/A
Building Type:
N/A
Commercial permit
2022-11-02
Eligible facilities request addition or replace antennas ancillary equipment and ground equipment as per plans for an existing carrier on an existing wireless communication facility. remove (6) rrhs remove (9) antennas remove (3) tmas remove (1) covp remove (6) coax cables and (1) hybrid cable ? install (6) antennas install (6) rrhs install (2) hybrid cables (1-1/2") remove all existi... see more
Valuation:
$25,000
Permit #:
PMT22-12221
Status:
final
Fee:
$520
Permit Type:
Macro cell site
Building Type:
N/A
Commercial permit
2022-09-27
Eligible facilities request addition or replace antennas ancillary equipment and ground equipment as per plans for an existing carrier on an existing wireless communication facility. · remove (6) antennas · remove (1) ovp · remove (6) 7/8 coax cables · remove (2) nsn hcs 100ft cables · relocate (3) antenna · install (6) antennas · install (6) rrhs · install (3) junction boxs · install... see more
Valuation:
$20,000
Permit #:
PMT22-10760
Status:
final
Fee:
$458
Permit Type:
Macro cell site
Building Type:
N/A
Commercial permit
2022-05-18
The requested modifications to the tower include: • removal of one (1) rrh per sector total of (3) • removal of one (1) tma per sector total of (3) • removal of three (3) microwave antennas • removal of three (3) mw line • removal of three (3) dual antenna brackets • removal of all downtilt brackets • removal of three (3) antennas per sector total of (9) • replace of one (1) rrh per s... see more
Valuation:
$20,000
Permit #:
PMT22-03392
Status:
expired
Fee:
$458
Permit Type:
Other commercial
Building Type:
N/A
Commercial permit
2022-03-31
Installing a new microwave dish and its associated cable on existing crown castle facility. no increase to tower height no expansion of ground footprint
Valuation:
$15,000
Permit #:
PMT22-05663
Status:
applied
Fee:
$170
Permit Type:
Macro cell site
Building Type:
N/A
Commercial alteration
2021-10-18
Remove and replace (9) antennas install (3) rrus install 1 ovp mount modifications 95-ft centerline install (1) ovp at ground level verizon
Valuation:
N/A
Permit #:
B202114638
Status:
filed
Fee:
$1,728
Permit Type:
N/A
Building Type:
N/A
Sign permit
2025-03-10
Sign
Valuation:
$15,000
Permit #:
B25-00557
Status:
complete
Fee:
$669
Permit Type:
N/A
Building Type:
N/A
Commercial alteration
2021-07-28
Swapping 3 antennas & rrh units 2 cabinets within an existing wireless communication facility
Valuation:
N/A
Permit #:
B202110693
Status:
filed
Fee:
$1,758
Permit Type:
N/A
Building Type:
N/A
Building permit
2019-03-14
Install 3 t-arm sector mounts 6 antenna 9 rrh and 4 hybrid cables. ground work is to install new lease area in an existing shelter 1 indoor equipment cabinet 1 ppc cabinet 1 telco cabinet 1 ciena box and 1 meter and disconnect
Valuation:
N/A
Permit #:
P18BP06246
Status:
final
Fee:
$237
Permit Type:
Commercial other
Building Type:
N/A
Commercial alteration
2021-08-20
Swapping 3 antennas & rrh units within existing wireless communication facility
Valuation:
N/A
Permit #:
B202111931
Status:
filed
Fee:
$1,406
Permit Type:
N/A
Building Type:
N/A
Commercial alteration
2021-08-11
Swapping 3 antennas & rrh units within existing wireless communication facility
Valuation:
N/A
Permit #:
B202111500
Status:
triage
Fee:
$1,406
Permit Type:
N/A
Building Type:
N/A
Commercial alteration
2022-06-22
At&t - replace equipment for existing wireless
Valuation:
N/A
Permit #:
B202209013
Status:
filed
Fee:
$1,554
Permit Type:
N/A
Building Type:
N/A
Floodplain permit
2018-11-14
Install 5 dish antennas 2 panel antennas 3 rrus 10 1/4 coax cables 94 lf 4 4"0 poles attached to the floor with braces and extending up wall to each side of the windows ground: intall 1 cabinet (sfha)
Valuation:
N/A
Permit #:
FP20180282
Status:
final
Fee:
$100
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # RCE-51261
111
BZ Score
$399K
Avg Project
-
Projects
License # 331149
90
BZ Score
-
Avg Project
-
Projects

Crown Castle Reviews

BuildZoom hasn't received any reviews for Crown Castle. Click here to be alerted when reviews are posted about them.
Please write a review about Crown Castle
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.