Updated: May 26, 2026
Location and Projects
Address
15811 ANNICO DRIVE, Homer Glen, IL, 60491
Use our bidding system to
request a quote
D&H Refrigeration HVAC/Mechanical Contractor
D&H Refrigeration, 15811 Annico Dr, Homer Glen, IL holds a General Contractor (Class C) license and 2 other licenses according to the City of Chicago license board.
Their BuildZoom score of 0 does not rank in the top 50% of Illinois contractors.
Their license was verified as active when we last checked. If you are thinking of hiring D&H Refrigeration, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
D&H Refrigeration Contact Information
Phone Number: (708) 308-0002
Edit
Address: 15811 ANNICO DRIVE, Homer Glen, IL 60491
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
D&H Refrigeration Homer Glen
Quality
Alert*
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
*No active license on file. If you are D&H Refrigeration, click “This is My Business” to update your information.
Activity
|
1 project
|
2024 |
|
2 projects
|
2023 |
Our building permit records indicate that D&H Refrigeration has worked on at least
3.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Pricing
|
1 project
|
$100k-$250k |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
New heat pump or refrigeration equip electrical work under this permit = no. locations: 0 residential unit(s) 1 non-residential unit(s) exterior work inside cooler
Valuation:
$150,000
Permit #:
B200401554
Status:
issued
Fee:
$525
Permit Type:
Mechanical work
Building Type:
N/A
Replace two evaporator condenser units with two 129 ton remote r717 bac evaporator condensers located on the roof and serving an ammonia plant. contact refrigeration supervisor clement gavin (312)743-3562 to schedule a rough inspection of the pump down and the test of the equipment
Valuation:
N/A
Permit #:
100970497
Status:
issued
Fee:
$600
Permit Type:
N/A
Building Type:
N/A
Replace existing refrigeration system serving the holding freezer with one russell 5 ton refrigeration system remote air cooled r404a located on the roof
Valuation:
N/A
Permit #:
100950537
Status:
issued
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Remove two fuller ammonia compressors and replace with one frick 300 ton ammonia compressor located in the engine room
Valuation:
N/A
Permit #:
101026945
Status:
issued
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Install one new evapco pmc-889e ammonia condenser located on the roof all piping and components included
Valuation:
N/A
Permit #:
101026964
Status:
issued
Fee:
$450
Permit Type:
N/A
Building Type:
N/A
New interior expansion to existing 2 story masonry commercial building -solo eye care & eyewear gallery
Valuation:
$30,000
Permit #:
100938342
Status:
expired
Fee:
$825
Permit Type:
N/A
Building Type:
N/A
Structural work only for remote terminal unit support at the roof as per plans
Valuation:
$10,000
Permit #:
100844885
Status:
complete
Fee:
$825
Permit Type:
N/A
Building Type:
N/A
2019 cbc: install new freeze concentration system an ammonia refrigeration system a condenser tower and an exterior overhead door in an existing 1-story building. as per plans
Valuation:
$2,400,000
Permit #:
100955227
Status:
complete
Fee:
$1,575
Permit Type:
N/A
Building Type:
N/A
Permit to correct violations: install new exhaust systems with ammonia detection, lights, horns & alarms singage on the doors and on the ammonia piping. replace corroded piping & vessels per analysis report. exhaust fans to meet required cfm per city code
Valuation:
N/A
Permit #:
100641445
Status:
issued
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Revision to permit #100548851. install two larkin 7 1/2 hp split systems air cooled r404a condensing units on the roof. the units serve the holding cooler
Valuation:
N/A
Permit #:
100627045
Status:
issued
Fee:
$600
Permit Type:
N/A
Building Type:
N/A
Replace existing 8 cylinder ammonia compressor with a new compressor a 75 hp 458xl manufactured by vilter corporation. the compressor serves high/low stage
Valuation:
N/A
Permit #:
100688340
Status:
issued
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Install one 200 ton ammonia heat exchanger(alfa laval) and one 70 ton exchanger(chester jensen) and all associated ammonia piping. exchangers are serving a egg processing plant. when work is complete call supervisor bob o'mara(312)743-7226 for an inspection
Valuation:
N/A
Permit #:
100662222
Status:
issued
Fee:
$600
Permit Type:
N/A
Building Type:
N/A
Convert cooler to freezer. install (2) two larkin condensing units and (4) four larkin evaporators. the condensing units are 12.3 tons each remote air cooled r404a located on the roof
Valuation:
N/A
Permit #:
100669330
Status:
issued
Fee:
$900
Permit Type:
N/A
Building Type:
N/A
Install three ammonia surge drums and one high pressure receiver for vinegar/cooling storage tanks. including all associated piping
Valuation:
N/A
Permit #:
100688346
Status:
issued
Fee:
$1,800
Permit Type:
N/A
Building Type:
N/A
Remove and replace eight isolation valves on ammonia condensers.isolation valves are 4 hansen globe valves
Valuation:
N/A
Permit #:
100628687
Status:
issued
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Ammonia pressure safety relief vent system - make compliant per psm standards & per design analysis report
Valuation:
N/A
Permit #:
100592268
Status:
issued
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Replace the existing water cooled condensers with one bohn 30 ton condenser three circuits remote air cooled r22 r409a r401a, 30# each circuit located on the roof serving cold storage
Valuation:
N/A
Permit #:
100528591
Status:
issued
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Install one new 170 ton alfa laval ammonia heat exchanger and a surge drum. for vinegar cooling process
Valuation:
N/A
Permit #:
100833566
Status:
issued
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Relocate two ammonia evaporators from the processing cooler to the holding cooler. furnish ammonia piping
Valuation:
N/A
Permit #:
100833549
Status:
issued
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Replace two 7 1/2 hp larkin condensing units and two remote evaporators with two copeland 7 1/2 hp condensing units and two remote evaporators air cooled r404a. the condensing units are located on the roof. relocate the existing production room evaporator to the receiving area
Valuation:
N/A
Permit #:
100509219
Status:
issued
Fee:
$400
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
122
BZ Score
$41.7K
Avg Project
-
Projects
118
BZ Score
$67.5K
Avg Project
-
Projects
License # TGC136428
Wheeling, IL
117
BZ Score
$175K
Avg Project
-
Projects
D&H Refrigeration Reviews
BuildZoom hasn't received any reviews for D&H Refrigeration. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an HVAC pro in your area today
We'll search our vast network of HVAC Pros and connect
you with one that meets your needs today.
Verified License
BuildZoom confirmed this contractor's license
D&H Refrigeration License info
Verified License
| License # | TGC105702 |
| Status | Active |
| City | City Of Chicago |
| Type | General Contractor (Class C) |
- BuildZoom verified this license was active as of May 2026.
Verify this license's status for D&H Refrigeration at the City of Chicago Data Portal.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | L-2015-013 |
| Status | Active |
| County | Kankakee County |
| Type | Hvac |
- When BuildZoom last verified this license, it had an expiration date of February, 2016. Check the current license status of D&H Refrigeration with the Kankakee County Planning Department
This is a sample of licensing data; click here to access a complete history.
Inactive License
| Status | Inactive |
| City | City Of Chicago |
| Type | C $5,000,000 Project Ceiling |
- According to the City of Chicago Data Portal, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are D&H Refrigeration, click “This is My Business” to update your information.
26
Permits
- Building permit records show that D&H Refrigeration has worked on 26 permitted projects.