Don't wait to get an Electrician

We make finding an electrician fast, easy, and commitment-free.

Call now (623) 259-4111
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >

Location and Projects

Address
303 LORIMER DR, Wyncote, PA, 19095
Use our bidding system to request a quote

David Bell Electrician

David Bell, 303 Lorimer Dr, WYNCOTE, PA (Employee: David S Bell) holds a Contractor license and 3 other licenses according to the Philadelphia license board.

Their BuildZoom score of 93 ranks in the top 27% of 125,106 Pennsylvania licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring David Bell, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

David Bell Services

Start a project today:

David Bell Contact Information

Phone: (215) 885-2193 Edit
Address: 303 LORIMER DR, WYNCOTE, PA 19095 Edit

Building Permits by David Bell

Sort by: Notable Notable | Date Date | Job Value Job Value
Electrical permit
2021-06-21
Install 200amp service three meters and wiring through out 2 family dwelling as per 2008 nec (south district)
Valuation:
$4,500
Permit #:
339619
Status:
complete
Fee:
N/A
Permit Type:
New construction
Building Type:
N/A
Electrical permit
2021-06-30
Remove and replace 200 amp svc;remove and replace 6 gang meter socket as per 2008 nec(5units/vac)
Valuation:
$3,800
Permit #:
473450
Status:
complete
Fee:
N/A
Permit Type:
New construction
Building Type:
N/A
Electrical permit
2021-04-06
Rewire to existing 100 amp panel thru out as per nec 2008 (sfd)
Valuation:
$3,000
Permit #:
414111
Status:
complete
Fee:
N/A
Permit Type:
New construction
Building Type:
N/A
Alteration permit
2013-07-29
Interior exterior alterations to renovate entire building to create pre-prepared cold food restaurant and accessory office space. construct new exterior ramp new exterior door in court area installation of new steel fire escape in courtyard area for existing building new fire rated floor/ceilings corridor and stair enclosure fit out new partitions bathroom furnishings interior stairs ... see more
Valuation:
N/A
Permit #:
471383
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2013-11-12
Amend permit # 499587 to correct address from 1829 to 1831 cottman ave - work descripton remains the same - install (18)high-hat fixtures (5)light fixtures (7)110volt outlets and 5)switches - all work to be in compliance with the 2008 nec (east district)
Valuation:
N/A
Permit #:
505029
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2013-09-16
Remove old wires near panel repair all exit & emergency lights cover junction boxes install gfi receptacles #6 ground wire only as per 2008 nec (daycare) ***no additional wiring and no other work to be done under this permit***
Valuation:
N/A
Permit #:
494928
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2012-11-13
Remove and replace front masonry wall two story-sfd masonry front wall - remove existing 2 story front masonry wall. replace with new 8 inch masonry wall (4 brick & 4 block) on existing foundation. windows and door same location u factor of 35 or better. new door opening for 36 inch door. horizontal reinforcement (durawall) every 24 inches. install returns into party walls for structu... see more
Valuation:
N/A
Permit #:
437637
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2013-01-29
200a service and complete rewire to include lights outlets sw recepts arc fault breakers gfi in kit and bathroom. no electric appliances. wiring for porch light doorbell and outside recepts. all work done in accordance with 2008 nec(sfd)(south dist)
Valuation:
N/A
Permit #:
450741
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2013-04-10
Remove & replace brick with block 7107 woodland ave.masonry front wall - remove existing front masonry wall. replace with new 8 inch masonry wall on existing foundation. windows and doors to comply with emergency egress standards per irc. new door opening for 36 inch door. flash roof to new front. vertical reinforcement every 24 inches. install returns into party walls for structural ... see more
Valuation:
N/A
Permit #:
464327
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2013-08-12
Ammend permit 312822 to reflect the installation of a new fire alarm system as per approved plans - no new plans submitted for review - permit for ammendment purposes only - fees waived as per r parissi
Valuation:
N/A
Permit #:
488682
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-01-25
Permit to complete work roughed in & inspected on permit #352296 replace service cable 200amp install all switches & devices outlets gfi outlets & light fixtures as per 2008 nec. all wiring done on first permit. no new wiring on this permit
Valuation:
N/A
Permit #:
384895
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Existing service total rewire, install new transformer rehab install all low voltage cat/5 & data as per 2008 nec. transformer secondary length to comply with article 240.21(c) of the 2008 nec
Valuation:
N/A
Permit #:
489761
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2012-02-16
Certificate of occupancy for a change of use lawful occupancy sign and installation of non-bearing partition wall with door adjacent to food preparation area. separate permits required for any mechanical electrical or plumbing work
Valuation:
N/A
Permit #:
383700
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2013-04-10
Rewire store & apartment hard wire smoke existing voltage fire alarm system as per nec 2008. installation to comply with article 210.52(b) of the 2008 nec.120v smoke detectors to be on an obvious lighting circuit
Valuation:
N/A
Permit #:
446237
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2011-05-13
Elec:install 100 ea layin 2x4 ceiling lts, (200)20a recp's, 60 ea lt switches, all wiring to be as per 2008 nec(west dis) fa:install fa system, pull stations, horns/strobes, exit signs, emer ltg/low voltage smk detectors wired to 2008 nec/nfpa-72(west dist)
Valuation:
N/A
Permit #:
321756
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2011-04-11
Install new drywall for single family dwelling. applicant agrees to limit the construction to comply with ez permit standard for interior alterations dated feb. 2007. deviations from this standard will result in the revocation of this permit and imposition of further penalties
Valuation:
N/A
Permit #:
335001
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2010-08-18
Connect 2 new sprinkler valve tamper switches and 1 ansul system into existing buildings f/a system install 1 additional horn strobe in basement relocate existing annunciator on 1st fl to front door area as per nfpa72 (cc district)
Valuation:
N/A
Permit #:
293130
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New construction permit
2013-05-20
For erection of a new four story addition (3) family apartment above an existing carport as per plans. additional permits required for electrical mechanical plumbing and fire suppression
Valuation:
N/A
Permit #:
387131
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2010-11-29
Laminate existing walls with drywall throughout. electrical and plumbing permits are also required for this renovation work. no penetrations through fire rated corridoor or stair shaft wall or floor/ceiling assembly is permitted
Valuation:
N/A
Permit #:
313919
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2008-01-04
Install new rubber roof system with drive from cap to roof stucco finish and remove replace front wall with 8 cmu back & 4 brick veneer over existing foundation with wall ties every floor level brick ties every 2 sq. ft. and weepholes 33 on center. remove all debris from premise and secure all openings
Valuation:
N/A
Permit #:
124916
Status:
ACTIVE
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

HIC # 053629
131
BZ Score
$8.5K
Avg Project
-
Projects
HIC # 064990
130
BZ Score
$2.2K
Avg Project
-
Projects
HIC # PA165781
149
BZ Score
$10K
Avg Project
-
Projects

David Bell Reviews

BuildZoom hasn't received any reviews for David Bell. Click here to be alerted when reviews are posted about them.
Please write a review about David Bell
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.