Updated: Jul 11, 2026
Location and Projects
Address
724 South Broad Street, Lansdale, PA, 19446
Use our bidding system to
request a quote
David BrandoLPh Electric Company
Their BuildZoom score of 0 does not rank in the top 50% of Pennsylvania contractors.
If you are thinking of hiring David BrandoLPh Electric Company, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
David BrandoLPh Electric Company Contact Information
Phone Number: (215) 855-7122
Edit
Address: 724 South Broad Street, Lansdale, PA 19446
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Building Permits by David BrandoLPh Electric Company
This is a sample of this contractor's permits. Click here to access their complete permit history.
Replace the existing lighting with new lighting relocate the existing 200amp service furnish and install new switches and gfci in the bathrooms furnish and install wiring for three hvac vav boxes per 2008 nec (commercial)
Valuation:
$14,000
Permit #:
437764
Status:
complete
Fee:
N/A
Permit Type:
New construction
Building Type:
N/A
Install 2x4 fixtures emerg & exit lighting, switches, sign circuit hvac wiring & recepts, relocate the existing 200amp service and provide new panel as per nec 2008.provide disconnects for water heater & sign per articles 422.31 600.6 of the 2008 nec
Valuation:
N/A
Permit #:
551042
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Basement electrical alterations (fire repair) - replace the existing peco end box and replace the existing 400amp two phase disconnect damage by a fire - replace all wiring damaged by the fire - the installation will comply with the 2008 nec
Valuation:
N/A
Permit #:
602469
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Seperate the wiring between the two stores new 200amp service remove the existing lighting fixtures & replace them with new fixtures recepts sw empty conduit for tele/data hvac wiring as per nec 2008 (north district)
Valuation:
N/A
Permit #:
562753
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Lighting fixtures recepts & switches addition 1-100amp panel 1-hvac unit (new) replace existing transormer w/a new 30 kva as per nec 2008 fire system addition 1-power supply for horn strobe as per nfpa 72
Valuation:
N/A
Permit #:
587158
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Rehang the existing track and track lighting 160 of track and 40 track heads. reinstall exist exit and emergency lighting as per 2008 nec. (center city dist.)
Valuation:
N/A
Permit #:
630278
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Existing 300amp single phase service to be reused install lighting fixtures, recepts and switches with hospital grade wiring as per 2008 nec (east district)
Valuation:
N/A
Permit #:
659403
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
64 light fixtures 16 receptacles 5 motions sensors relocating power for washer and dryers addition bathroom light and receptacles power for the hand dryer relocate 3 existing fa devices per 2008 nec & nfpa 72(homeless shelter)
Valuation:
N/A
Permit #:
474044
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Furnish & install new lighting receptacles & switches 1-hvac unit 1 new 60 amp panel & 3-new horn strobes (health care facility) as per nec 2008 (north dist)
Valuation:
N/A
Permit #:
565771
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Furnish & install new lighting receptacles & switches 1-hvac unit 1 new 60 amp panel & 3-new horn strobes (pharmacy) as per nec 2008 & nfpa 72 (north dist)
Valuation:
N/A
Permit #:
565773
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove 18-2x4 light fixtures and install 8 rows(16'each)of track lighting, all work is from the existing electrical panel as per 2008 nec (cc district)
Valuation:
N/A
Permit #:
579936
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Renovations to existing building relocate some existing panels some new panels new light fixtures receptacles and gfci's all as per 2008 nec. all 2x4 light fixtures designated a are emergency with battery back-up
Valuation:
N/A
Permit #:
338982
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New led lighting recpts & switches hvac wiring x-ray wiring existing panel drawing enclosed as per nec 2008. installation to comply with article 517.13 of the 2008 nec
Valuation:
N/A
Permit #:
501925
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Existing feeder toapt above bakery are connect to house panel disconnect the two apartment from house panel & install peco metering & disconnect for two apartment as per nec 2008 (mixed use)
Valuation:
N/A
Permit #:
468780
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Addition pull stations and horn strobes. 2-smoke detectors in the basement as per nfpa72(cc district)
Valuation:
N/A
Permit #:
668688
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Rewiring of kitchen. furnish and install 6 recepticals and 8 high hats and two switches as per 2008 nec (south district)
Valuation:
N/A
Permit #:
607045
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Addition 1 smoke detector 1 pull station 4 horn strobes 1 facp addition to existing as per nfpa 72
Valuation:
N/A
Permit #:
676855
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New 200 amp service new kitchen receptacles 20 light fixtures 2 gfci in bathroom
Valuation:
N/A
Permit #:
675249
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New lights receptacles switches & emer/exit lights as per nec 2008 east district
Valuation:
N/A
Permit #:
709639
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New outlets switches and lights new hard wired smoke detectors as per nec 2008
Valuation:
N/A
Permit #:
695611
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
HIC # 053629
Philadelphia, PA
131
BZ Score
$8.5K
Avg Project
-
Projects
130
BZ Score
$2.2K
Avg Project
-
Projects
149
BZ Score
$10K
Avg Project
-
Projects
David BrandoLPh Electric Company Reviews
BuildZoom hasn't received any reviews for David BrandoLPh Electric Company. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
David BrandoLPh Electric Company License info
License Not Verified
| HIC # | 34FA00057300 |
| Status | Active |
| State | New Jersey |
| Type | Electrical Contractors |
- When BuildZoom last verified this license, it had an expiration date of August, 2019. Check the current license status of David BrandoLPh Electric Company with the New Jersey Department of Law & Public Safety
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| HIC # | PA003906 |
| Status | Active |
| State | Pennsylvania |
| Type | Electrical Contractor |
- When BuildZoom last verified this license, it had an expiration date of July, 2017. Check the current license status of David BrandoLPh Electric Company with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | PA003906 |
| Status | Inactive |
| State | Pennsylvania |
- According to the Pennsylvania Office of the Attorney General, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for David BrandoLPh Electric Company at the Pennsylvania Office of the Attorney General.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | 16777 |
| Status | Inactive |
| City | Philadelphia |
| Type | Electrical Contractor |
- According to the City of Philadelphia Licensed Contractors, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for David BrandoLPh Electric Company at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | 34EB01544900 |
| Status | Inactive |
| State | New Jersey |
| Type | Electrical Business Permit |
- According to the New Jersey Department of Law & Public Safety, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for David BrandoLPh Electric Company at the New Jersey Department of Law & Public Safety.
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are David BrandoLPh Electric Company, click “This is My Business” to update your information.
Insured
| Insurer | Walsh Bagley Mckenna & Associates |
| Insured up to | $1,000,000 |
49
Permits
- Building permit records show that David BrandoLPh Electric Company has worked on 49 permitted projects.
David BrandoLPh Electric Company Employees
DI
David Brandolph Electric Co In
DB
David S. Brandolph
Vice President
JL
Joseph L Landue
Electrical Project Manager