Dennis L Marchello, 1318 Riverbank Rd, Stamford, CT (Employee: Dennis Marchello) holds a Electrical Unlimited Contractor license according to the Connecticut license board.
Their BuildZoom score of 90 indicates that they are licensed or registered but we do not have additional information about them.
Their license was verified as active when we last checked. If you are thinking of hiring Dennis L Marchello, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Change existing over head 100 amp service to 200 amp underground service and relocate meter main to new location off of screened in porch to side wall of existing garage as per eversource. crs number 3244841
Level 1 & 2 pantry renovations. demo existing power outlets and light fixtures. install new power outlets and light fixtures. 1 new 45kva, 480-120-208v, nema 1transformer with primary feeder. 1 new 225/150a mcb, 120/208v, 42-pole nema 1 panel.
Furnish and install new 400a, 120/208v, 3-phase, 4-wire, 42-pole, nema 3r outdoor panel for temporary power at construction site. furnish and install new 400a underground feeder connected to the existing 400a ug feeder. provide 120v gfi receptacles with in-use covers. provide temporary wiring for temp. lights, temp. site lighting and construction trailers.
New siemens fire alarm system. new main fire alarm control panel speaker/strobe lights area smoke detectors pull stations warden stations elevator recall wf/ts roof top hvac shutdown fire smoke damper shutdown kitchen and boiler gas valve shut-off ansul system monitoring fire pump monitoring lobby remote annunciator
Part of an active project permit # m-15-833. disconnect existing rooftop air conditioning unit rtu-3 for replacement of same kind by others. re-connect existing 300a 480v power feeder. re-connect controls. re-install lightning protection
Remedial electrical work due to rooftop rtu fire in november 2015. electrical scope: replaced (2) 120/208v 200a panels in the 2nd floor it room and replaced (30) down lights with all new wiring in the corridor of the 2nd floor.
Install (4) electric vehicle charging station at the front parking lot area. install (4) 60a 208v circuits from the existing panel in the basement. route pvc conduits underground to the charging stations.
Disconnect existing rooftop a/c unit rtu-4 for replacement of same kind by others. re-connect existing 300a 480v power feeder. re-connect controls. re-install lightning protection.