Hvac/water heater: hvac change out=heat pump split system=5 tons 18 seer 8 hspf 60k btus. change out 80 gallon water heater. the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. cf-1r-alt-hvac on file: carbon monoxide & smoke alarms required. reference crc section... see more
Replace (e) heat pump w high efficiency heat pump split system. replace 50 gal wh w tankless. location exterior wall in backyard (e) 3/4 gas line. the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%. cf-1r-alt-hvac on file: carbon monoxide & smoke alarms required.... see more
No duct work permitted. change-out split system to split system (all-electric heat pump). the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%
No duct work permitted. change-out split system to split system (all-electric heat pump). the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%
Valuation:
$12,500
Permit #:
RES-2510661
Status:
final
Fee:
$229
Permit Type:
N/A
Building Type:
Single family
Miscellaneous electrical plumbing mechanical solar/pv electric vehicle charger generator (not for re
Replacement of sewer line located in backyard. approximate footage is 23 feet sewer line replacement would include a bullhorn clean out. material to be used 4 inch abs pipe. hand dig exposed a trench. replacement of existing 50 gallon gas water heater with new 50 gallon gas water heater ultra lonox. water heater replacement in existing location in garage
Changeout to existing hvac system only. no additional electrical mechanical plumbing or structural work permitted.; removed existing natural gas roof package unit and replace with high-efficiency to stage heat pump pack unit in same location
Water heater changeout only. no additional electrical mechanical plumbing or structural work permitted.; remove and replace existing 50 gallon gas water heater with new 50 gallon gas water heater in same location. location in the garage. customer already has smoke and carbon monoxide detectors installed
No duct work permitted. change-out split system to split system. the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%
Water heater changeout only. no additional electrical mechanical plumbing or structural work permitted.; remove existing gas water heater 50 gallon and replace with 80 gallon electric heat pump water heater located in garage
Water heater changeout only. no additional electrical mechanical plumbing or structural work permitted.; removed and replaced existing 40 gallon gas water heater with current code upgrades. location and exterior closet
No duct work permitted. change-out roof mount (all-electric heat pump) to roof mount (all-electric heat pump). the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%
No duct work permitted. change-out split system to split system (all-electric heat pump). the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%
No duct work permitted. change-out split system to split system (all-electric heat pump). the existing unit shall be removed. the new unit shall be placed in the same location as the existing unit and shall not exceed the size of the existing unit by more than 25%
Water heater changeout only. no additional electrical mechanical plumbing or structural work permitted.; install new 50 gallon natural gas ultra lonox water heater in existing location at exterior closet
Water heater changeout only. no additional electrical mechanical plumbing or structural work permitted.; remove and replace existing gas water heater like for like in the same location
Changeout to existing hvac system only. no additional electrical mechanical plumbing or structural work permitted.; hvac c/o heat pump split system 3 ton 18 seer 8 hspf 36k btu
Valuation:
$12,545
Permit #:
HACR2025-00675
Status:
complete
Fee:
$493
Permit Type:
N/A
Building Type:
N/A
Miscellaneous electrical plumbing mechanical solar/pv electric vehicle charger generator (not for re
Remove old gas fired furnace from indoor closet and replace with split system high efficiency heat pump. old system only had two ducts so we added an additional duct work in r8 to remaining of the house. system is located in the same location with the heat pump outside in back yard at corner of the home
Changeout to existing hvac system only. no additional electrical mechanical plumbing or structural work permitted.; hvac c/o gas to elect. conv. heat pump split system 4 ton 18 seer 8 hspf 48k btu
Water heater changeout only. no additional electrical mechanical plumbing or structural work permitted.; remove and replace existing 50 gallon gas water heater located in the garage with 80 gallon electric heat pump same location. existing electrical used at this location
Changeout to existing hvac system only. no additional electrical mechanical plumbing or structural work permitted.; replacement of gas furnace and air conditioning with 18 seer high efficiency split system heat pump. we are not changing the existing location. air handler/furnace will be located in the closet and outdoor ac/heat pump is located on the side yard