Replace current heating system with a bosch inverter ducted split system. bosch 2.0 heatpump - bova36hdn10m20 20 seer 10.5hspf - bgh96m060 96% afu gas furnace 2 stage - 3ton cased coil bosch with txv 2 new t6 thermostats 1 honeywell integrated zone controller for dual fuel applications and outside air sensor condensate pump with acid neutralizer highrise condenser pad whip & disconnec...
see more
Building Type:
R-residential
To remove and replace two existing air handlers and air conditioning condensers one for the first floor and one for the second floor 1st floor 3 ton air handler and a 3 ton 16 seer condenser - 2nd floor 4 ton airhandler and a 4 ton 16 seer condenser
Permit Type:
Air conditioning ...
Install geothermal heat pumps to replace the existing heating system and to addition air conditioning
Building Type:
Must verify
Replace existing server room air conditioning unit with 1-carrier 50psv036jcc5acax 3 ton 208v 3 ph vertical water source hp1-5 media filter with metal cabinet and grill1-supply plenum with metal directional diffusers1-water line connections with purge and isolation valves. insulated1-digital programmable wifi thermostat1-condensate drain assembly with pump1-wet switch for emergency sh...
see more
Permit #:
BT-MECH-2020-02613
1 goodman gmec960402bna 96% afue condensing gas furnace. 1 goodman gsx160181f 1.5 ton 16 seer air conditioning condensor with pad. 1 goodman capf1824a6 cased coil. 1 honeywell t6. all necessary ducting to include galvanized plenums and trunk lines with flexible supply runs and one centralized filter grill return. all necessary pvc venting drains and low voltage control wiring. 1 navia...
see more
Permit #:
MISC-MEC-20-171026
1 goodman mgec960402bna 96% afue condensing gas furnace. 10goodman gsx160181f 1.5 ton 16 ser air conditioning condensor with pad. 1-goodman capf1824a6 cased coil. 1-honewell t6. all necessary ducting to include galvinaized plenums and trunk lines with flexible supply runs and one centralized filter grill return. all ncesessary pvc venting drains and low voltage control wiring. 1 navie...
see more
Permit #:
MISC-MEC-20-171139
Install 80% efficient gas furnaces. equipment provided by property we are only providing labor install 80% efficient gas furnaces. equipment provided by property we are only providing labor
1-goodman 96 high eff nk- furnace gmec960603aw - goodman condenser gsx160241- gas and coil -gas line pressure test duct work metal and flex
Permit #:
MISC-MEC-21-171557
Install amana central air conditioning system install amana central air conditioning system
Permit Type:
Air conditioning
Change 10 dead compressers d508 d502, b408, d507, c507, e420, e509, e121, d405, c011 change 10 dead compressers d508 d502, b408, d507, c507, e420, e509, e121, d405, c011
Permit Type:
Air conditioning
Install high efficent hall gas furnance on first floor and repair duct work. addition 1.5 ton cased coil and landenser for floor 1 2 3. change grills on 2nd and 3rd fl
Permit #:
MISC-MEC-19-170471
Roof replacement flashing ridgevent drip edge tape joints ice & water. 16sq
Permit #:
RES-ALT-22-000299
Installation of a single zone space pak small duct high velocity system for 2nd/3rd fl
Permit #:
MISC-MEC-21-171429
Remove and replace existing 1.5 ton air handler and heat pump
Permit #:
MISC-MEC-22-171852
Install new duct work and goodman gmec960402 gus furnace 6sx1601s1 condensor capt3131 casrol coil. addendum: addition water heater
Permit #:
MISC-MEC-19-170302
Install gas furnace new gas line new duct work install navien npe 180 on demand water heater
Permit #:
MISC-MEC-20-170710
Roughing in new shower w/shower valve installing new toilet and vanity sink installing new kitchen sink w/dishwasher relocating washing machine hook up gas piping on demand water heater
Permit #:
MISC-PLM-17-172494
Installation of a amana modulating 97% afue condensing furnace with a 2 stage air conditioning system. removal of air handler oil furnace and wood furnace. tie all existing duct work together and install propane furnace with condenser and a coil. amana amvm97100 amana asxc160481 installation of a amana modulating 97% afue condensing furnace with a 2 stage air conditioning system. remo...
see more
Install new gas fired furnace and air conditioning with all associated duct work
Permit #:
MISC-MEC-17-169146
Install navien hot water heater and a gorman gas fired furnace along with ductwork
Permit #:
MISC-MEC-17-169408