Family owned roofing company. With C 39 roofing license and all required insurance obligations.
We are doing construction projects and roofing projects for the last 35 years.
We have recently incorporated in order to upgrade and take commercial and goverment projects.
From BuildZoom: Eba Roofing Inc, 14140 Moorpark St, Sherman Oaks, CA (Owned by: Ben Ari) holds a Roofing license according to the California license board.
Their BuildZoom score of 114 ranks in the top 2% of 336,931 California licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Eba Roofing Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Re-roof with class a or b roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 28 squares. class a roof covering is required within very high fire hazard severity zone (vhfhsz). for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required... see more
Reroof with 28 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Re-roof with class a or b roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing (10) squares. class a roof covering is required within very high fire hazard severity zone (vhfhsz). for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roofing rating council (crrc). cool roof may be req... see more
Reroof with 28 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 35 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 20 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 11 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 29 sqrs comparable shingle roofing over new solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 30 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Re-roof with class a or b material weighing less than 6 pounds per sq. ft. over existing solid sheathing ___28___squares. class a roof covering is required within very high fire hazard severity zone (vhfhsz). for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-... see more
Reroof with 30 sqrs built up roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 42 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 28 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 32 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Re-roof main house and detached garage. tear off (e) layer and install new comparable shingles. install new plywood on the (e) deck. total of 2300 sf. subject to field verification
Reroof with 23 sqrs comparable shingle roofing over new solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 30 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 23 sqrs comparable shingle roofing over new solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 25 sqrs comparable shingle roofing. existing solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Reroof with 22 sqrs built up roofing over new solid sheathing. re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Valuation:
$6,600
Permit #:
20016-90000-11033
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type: