Don't wait to get an Electrician

We make finding an electrician fast, easy, and commitment-free.

Call now (623) 259-4111
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >

Location and Projects

Address
611 CENTRAL PARK DR SANFORD, FL 32771, Sanford, FL, 32771
Use our bidding system to request a quote

Echo Ed Electrician

Echo Ed Corp, 611 Central Park Dr, Sanford, FL (Owned by: Daniel Fernandez) holds a Contractor license and 10 other licenses according to the Clermont license board.

Their BuildZoom score of 111 ranks in the top 4% of 191,428 Florida licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Echo Ed Corp, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Echo Ed Corp Services

Start a project today:

Echo Ed Corp Contact Information

Phone: (407) 930-4333 Edit
Address: 611 CENTRAL PARK DR SANFORD, FL 32771, Sanford, FL 32771 Edit

Echo Ed Corp Sanford

Quality

111
96th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Echo Ed Corp has a BuildZoom score of 111, which places them above 96% of 191,428 contractors in Florida.

Activity

34 projects
2025
17 projects
2024
20 projects
2023
Our building permit records indicate that Echo Ed Corp has worked on at least 71.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

5 projects
Commercial Renovations
5 projects
New Constructions
4 projects
Home Additions
55 projects
Electrical projects
Analyzing permits over the last 4 years shows that Echo Ed Corp mostly works on electrical project and new construction projects.

Pricing

12 projects
< $5k
13 projects
$5k-$20k
20 projects
$20k-$50k
10 projects
$50k-$100k
7 projects
$100k-$250k
4 projects
$250k-$500k
1 project
$500k-$1mil
1 project
$1mil+
Value Not Public: 16.0 projects
The typical size of their permits is approximately $25,414. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Echo Ed Corp

Sort by: Notable Notable | Date Date | Job Value Job Value
Electrical permit
2025-06-26
Install (4) square d type nq panels (furnished by skywater) each rated at 400a 120/208v 3-phase 4-wire sccr: 10ka 42 qob pole spaces surface-mounted. furnish and install feeders for the four (4) panels (furnished by skywater) consisting of 3” emt conduit with compression fittings supported by strut and pulled with (4) 500 kcmil copper conductors and (1) #3 thhn copper ground conductor... see more
Valuation:
$99,620
Permit #:
A25-005382
Status:
issued
Fee:
$12
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-07-09
Install two 350a 3p feeders (tl-swb2n1a to power cabinet power cabinet to wet116) and a square d 350a 3p 208v breaker. install (3) 20a 1p 120/240v breakers and (3) cat6 cables in 1-1/4” conduit to cdu122 wcs123 and wet116. install (1) quad receptacle on the fab level and a 20a 1p 120v branch circuit from tl-p2n1a/b to cdu112 wcs123 fss122 and wet116
Valuation:
$74,870
Permit #:
A25-003722
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-10-30
P feeder (2”c: 4#1/0 + #6g) to plate 113 and a square d 150a 3p 65ka@208v breaker. install (6) 20a 1p 120/240v breakers and (1) 25a 1p 120/240v breakers a new branch circuit from panel tl-p2n1e to anc121 rds121 cdu121 wcs122 wcs121 and plate 113 quadplex receptacle. route vendor-furnished cables via 1-1/4” conduit from plate 113 to vacuum pump and anc121 to anc122 as per tool#10-plate... see more
Valuation:
$59,920
Permit #:
A25-003720
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-07-09
Install a 150a 3p feeder (1-1/2c: 3#1/0 + #6g) and connect to the main terminals of the electrical enclosure. install a square d i-line 150a 3p breaker (65ka@208v). install a 12 x 4 wire basket cable tray from the electrical enclosure to the dosing equipment in the sub-fab routing vendor-furnished cables through a new 2” conduit to the raised floor cavity. route and terminate cables a... see more
Valuation:
$47,870
Permit #:
A25-003718
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-08-21
Quick permit - relocate the existing 150kw 3ø 277/480v diesel generator with 850-gal sub-base tank. demolish feeders communication conduit/wiring w/h and battery charger circuits from ats to generator. install new feeders communication conduit/wiring and w/h and battery charger circuits. feeder sizing to remain the same
Valuation:
$30,600
Permit #:
A25-005516
Status:
final
Fee:
$133
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-06-25
Tool #44a/b ldr111/uldr11 - scope of work: install (2) square d 20a 3p 120/208v circuit breakers in panel tl-p2n1u. install (2) 20a 3-phase 208v branch circuits from panel tl-p2n1u to tools ldr111 and uldr111. per craig van dyk exclude work shown on drawing e.44ab-100 keynote #3: (2) cat6 cables in shared 1¼ conduit and terminations from owner equipment to patch panels in server room ... see more
Valuation:
$30,120
Permit #:
A25-005392
Status:
issued
Fee:
$12
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-09-10
Provide and install one (1) square d 60a 3-pole 240v qob circuit breaker and one (1) square d 20a 1-pole 120/240v breaker. install four (4) 20a 120v quadplex surface-mount receptacles a 60a 3-phase feeder from panel tl-p2n1d to lmark112 and a 20a 1-phase circuit from the same panel to feed the receptacles. provide and install one (1) cat6 cable in 1-1/4” conduit with associated termin... see more
Valuation:
$29,220
Permit #:
A25-004555
Status:
final
Fee:
$137
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-05-08
Install (2) 50a 2p 240v qob breakers (2) 30a 2p 240v hd fused disconnects and (2) 5kva 208v-230v transformers. install 50a 1ø feeders from panel tl-p2n1j to transformers t-efem and t-a6. install 30a 1ø feeders from transformers t-efem and t-a6 to dattach111-efem and dattach111-a6 respectively. provide direct tool power connections. install (1) cat6 cable in 1-1/4 conduit with terminat... see more
Valuation:
$25,920
Permit #:
A25-003890
Status:
issued
Fee:
$137
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-06-10
Provide and install a 20a 3p feeder from panel tl-p4n1a to a 15kva transformer then to a 30a 600v 3p fused hd disconnect switch and extend to the ldi112 main power cabinet. install (1) square d 20a 3p 480/277v circuit breaker and (2) square d 20a 1p 120/240v circuit breakers. provide and install (2) dedicated 20a branch circuits from panel tl-p2n1j to (2) quadplex 20a receptacles. rec... see more
Valuation:
$26,730
Permit #:
A25-003726
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-06-10
Install a 30a 3p feeder from panel tl-p4n1a to 15kva transformers then extend the circuit to the ldi111 main power cabinet. install (1) 15kva transformer. install (1) square d 30a 3p 480/277v circuit breaker. install (1) 30a 600v 3p fused hd disconnect switch. install (1) square d 20a 1p 120/240v circuit breaker. install (2) 120a 20a dedicated branch circuits from panel tl-p2n1j to th... see more
Valuation:
$26,610
Permit #:
A25-003725
Status:
issued
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-07-16
Install (1) 70a 3p feeder from panel tl-p2n1c to cure113 with (1) square d 70a 3p 240v qob circuit breaker. install (1) 30a 3p feeder from the same panel to the chiller with (1) square d 30a 3p 240v qob circuit breaker. install cat6 cable in 1-1/4 conduit with terminations from owner-provided equipment to patch panels in server room 113 for lan connectivity; mount new data receptacle ... see more
Valuation:
$21,610
Permit #:
A25-003729
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-07-16
Install (1) 70a 3p feeder from panel tl-p2n1c to cure112. install (1) square d 70a 3p 240v qob circuit breaker. install (1) 30a 3p feeder from panel tl-p2n1c to chiller. install (1) square d 30a 3p 240v qob circuit breaker. install (1) cat6 cable in 1-1/4"c and associated terminations from owner-provided equipment to patch panels in existing server room 113 for owner lan network conne... see more
Valuation:
$21,330
Permit #:
A25-003728
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-08-11
Provide and install a 40a 3p feeder from sub-fab level panel tl-p2n1c to uvtreat111 @ fab level. provide and install up to 80ft of cat6 cable. provide and install the required equipment connection conduit pull-box j-box wiring compression fittings and supports
Valuation:
$9,640
Permit #:
A25-003727
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-06-18
Provide and install (6) square d 20a 1-pole and (1) 40a 3-pole circuit breakers in panel tl p2n1g and (1) 250a 3-pole 65ka circuit breaker in panel tl-swb2n1a. install a 250a 3-pole feeder from panel tl-swb2n1b to tool trak113. provide branch circuits for tcu cwsh111 co2fs cwsh111-co2fs wcs-a and ecs-b. per drawing e.32-100 keynote #3 install a 12 wide by 4 high wire basket cable tray... see more
Valuation:
$56,680
Permit #:
A25-005028
Status:
issued
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-10-02
Install square d breakers (90a 60a 50a in panel tl-swb2n1e; 20a in panel tl-p2n1q) with corresponding circuits to dbg111 equipment and a 20a quadplex receptacle. receive and install vendor-furnished communication/power cables via new cable tray with vendor performing final terminations. provide all required conduit boxes wiring fittings supports and interconnects
Valuation:
$48,230
Permit #:
A25-007191
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-11-21
Provide and install (5) square d 20a 1-pole breakers in panel tl-p2n1e and (1) 250a 3-pole 65ka breaker in panel tl-swb2n1a along with a 250a 3p feeder to tool swc111. per drawing e.12-100 keynote #3 install a 12"w x 4"h basket cable tray on the sub-fab for routing vendor-supplied cables between swc111 accessory equipment. as directed by craig van dyk item #7 and all related component... see more
Valuation:
$46,660
Permit #:
A25-005029
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-08-28
Install (1) 60a 3-pole and (1) 20a 1-pole breakers in tl-p2n1r and (1) 90a 3-pole breaker in tl-d2n1g. provide 60a feeder tl-p2n1r?dtg111 (dtu1550) 20a circuit tl-p2n1r?dtg111 (quadplex) and 90a feeder tl-d2n1g?dtg111 (dgp8761). install 12"x4 wire basket tray under raised floor for vendor cables per keynote #3. provide work per interconnection keynotes #1 & #2. install 20a 120v surfac... see more
Valuation:
$29,870
Permit #:
A25-007472
Status:
issued
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-06-18
Provide and install the following square d circuit breakers in panel tl-p2n1r: one (1) 60a 3-pole 120/208v; one (1) 30a 3-pole 120/208v; and two (2) 20a 1-pole 120/208v. provide and install a 60a 3-phase feeder from panel tl-p2n1r to tool dsaw111 dtu1550 and a 30a 3-phase feeder to tool dsaw111 dfd6363. provide and install a 20a 1-phase branch circuit from panel tl-p2n1r to a surface-... see more
Valuation:
$27,420
Permit #:
A25-005023
Status:
issued
Fee:
$137
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-08-26
Provide and install one square d 40a 2-pole 120/240v 10ka circuit breaker (model qob240epd) with 30ma ground fault protection (type b taa compliant). provide and install one square d 20a 1-pole 120/240v circuit breaker and one 20a 120v quadplex surface-mount receptacle. install one 40a 2-phase feeder from panel tl-p2n1d to tool #39 (treel111) and one 20a 1-phase circuit from the same ... see more
Valuation:
$20,420
Permit #:
A25-004804
Status:
final
Fee:
$4
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-08-26
Per drawing e.43-100 keynote #3 provide and install one square d 30a 3-pole 120/208v circuit breaker in panel tl-p2n1u a 30a 208v 3-phase feeder to tool wafxfer111 and one cat6 cable in 1-1/4 conduit with terminations from owner-provided equipment to patch panels in server room 113 on the sub-fab level for lan connectivity. include all required equipment connections conduit pull boxes... see more
Valuation:
$11,890
Permit #:
A25-007146
Status:
issued
Fee:
$137
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # B-74579
131
BZ Score
$6K
Avg Project
-
Projects
License # ER13012549
131
BZ Score
$7.8K
Avg Project
-
Projects
License # CGC1532433
127
BZ Score
$160K
Avg Project
-
Projects

Echo Ed Corp Reviews

BuildZoom hasn't received any reviews for Echo Ed Corp. Click here to be alerted when reviews are posted about them.
Please write a review about Echo Ed Corp
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.