We'll help you find the right contractor.

Share your project details and we'll reach out to Eco Electric LLC so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started

Location and Projects

Address
749 N Ralstin St, Meridian, ID, 83642
Use our bidding system to request a quote

Eco Electric LLC

Their BuildZoom score of 108 ranks in the top 5% of 53,194 Idaho licensed contractors.

If you are thinking of hiring Eco Electric LLC, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Eco Electric LLC Contact Information

Phone: (208) 392-1470
Address: 749 N Ralstin St, Meridian, ID 83642

Eco Electric LLC Meridian

Quality

108
95th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Eco Electric LLC has a BuildZoom score of 108, which places them above 95% of 53,194 contractors in Idaho.

Activity

18 projects
2025
17 projects
2024
23 projects
2023
Our building permit records indicate that Eco Electric LLC has worked on at least 58.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

19 projects
Home Additions
57 projects
Electrical projects
Analyzing permits over the last 4 years shows that Eco Electric LLC mostly works on electrical project and home addition projects.

Pricing

5 projects
< $5k
Value Not Public: 53.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Eco Electric LLC

Sort by: Notable Notable | Date Date | Job Value Job Value
424-544-electrical
2025-05-23
Install a new 20 amp 120 volt dedicated from the basement panel to the outside septic pump control. will need to bring power out of the panel and through the concrete wall. install wiring into schedule 80 conduit along the wall to bring it inside the pump controller and make the final connections
Valuation:
N/A
Permit #:
ELE25-01601
Status:
final
Fee:
$55
Permit Type:
Repair
Building Type:
Single family dwe...
424-544-electrical
2025-03-19
2308 and2310 palouse st boise id provide and install 2 new outdoor panels since they are not water tight any longer and at the end of their useful life. moisture has been seeping into the panel causing the breakers and buss bar to become very corroded. install a new 100 amp weather rated panel along with new breakers inside of the panel upgrade grounding and feeders as needed. will ne... see more
Valuation:
N/A
Permit #:
ELE25-00819
Status:
final
Fee:
$130
Permit Type:
Repair
Building Type:
Single family dwe...
424-544-electrical
2025-05-07
Install a new outlet for the refrigerator. ensure that the wiring in the kitchen is gfi protected and conforms to codes for spacing wire for 3 outlets inside of the new pantry area wire for 3 wafer lights inside of the pantry with 2 switches/switchlegs operating them with a stack switch. one will operate 2 lights and the other 1 light. move the range box and wiring into the wall. inst... see more
Valuation:
N/A
Permit #:
ELE25-00765
Status:
final
Fee:
$55
Permit Type:
Alteration
Building Type:
Single family dwe...
424-544-electrical
2025-02-18
Upgrade the existing 100 amp panel to a new 40/80 space eaton main breaker panel with all new breakers. upgrade the feeders the grounding and the meter base. install a new intersystem grounding device a whole house surge protector and expansion joint for the riser. install a new 50 amp 240 volt circuit to the opposite side of the garage for a new nema 14-50 ev charging outlet
Valuation:
N/A
Permit #:
ELE25-00483
Status:
final
Fee:
$110
Permit Type:
Alteration
Building Type:
Single family dwe...
424-544-electrical
2025-01-08
Provide and install a new utility post to be put at the top of the hill for idaho power to connect to. bring the power in overhead to the new pole and feed it into a new 200 amp panel. bring power out of the bottom of the panel and feed it to the house with new feeders connect new conduit to the old and install new feeders from the main panel on the post to the subpanel inside the house
Valuation:
N/A
Permit #:
ELE25-00052
Status:
final
Fee:
$55
Permit Type:
Repair
Building Type:
Single family dwe...
Existing residential electrical (remodel/additions)
2025-07-29
Install a new gfi-protected outlet in the soffit for the powered patio shades to be plugged into. a1h; at install constant power into the patio cover where the brace has been installed. will need to find power in the attic and drill a hole from the house into the patio shade. then fish wiring through the hole to the location where the fan will be installed. make an opening for the wir... see more
Valuation:
N/A
Permit #:
R-ELCEX-2025-0253
Status:
final
Fee:
$40
Permit Type:
N/A
Building Type:
N/A
Existing residential electrical (remodel/additions)
2025-07-07
Wire for 20 amp gfi protected outlets at the back of the linen closet (quad outlet) and on each side of the vanity sink. move the exhaust fan location. provide and install a new panasonic sv-1115vkl3 exhaust fan with humidity sensor module installed. provide and install a wall mounted timer to operate the exhaust fan. provide and install 3 new wafer lights that will be operated with a... see more
Valuation:
N/A
Permit #:
R-ELCEX-2025-0221
Status:
final
Fee:
$40
Permit Type:
N/A
Building Type:
N/A
424-544-electrical
2025-07-01
Trim out only provide and install breaker lock outs on the square d panel as needed label the main panel install a new bell box weather proof gfi outlet and in use weather proof cover on the front corner of the house provide and install a new gfi protected hot tub disconnect at the back of the house provide and install a new switch for the furnace to act as a disconnect provide and in... see more
Valuation:
N/A
Permit #:
ELE25-02093
Status:
final
Fee:
$55
Permit Type:
Alteration
Building Type:
Single family dwe...
424-544-electrical
2024-12-11
Remove the existing service fuse panel illegal external wiring and overhead feed. will need to bring the riser feeders and weather head to the nw side of the house to avoid the back patio cover and yet stay away from the windows per idaho power's regulations. will then feed them into a new 100 amp all in one panel on the back of the house from this panel feed the circuits into the exi... see more
Valuation:
N/A
Permit #:
ELE24-03840
Status:
final
Fee:
$55
Permit Type:
Repair
Building Type:
Single family dwe...
424-544-electrical
2025-03-06
Remove damage meter pack and install new meter pack in it's place. install new 3 expansion on conduit feeding into meter pack. install 4 new 100 amp main breakers to feed existing units
Valuation:
N/A
Permit #:
ELE25-00668
Status:
final
Fee:
$65
Permit Type:
Repair
Building Type:
Multiple family d...
424-544-electrical
2025-02-18
Install 3 additional outlets (one on each wall) in the fly tying room replace the ceiling light with a new customer supplied one wire for provide and install new under cabinet led tape lighting underneath the shelving. will need to install a new switch and driver to operate the new lights replace the light fixtures in the spare bedrooms with new customer supplied ones in the master be... see more
Valuation:
N/A
Permit #:
ELE24-03414
Status:
final
Fee:
$55
Permit Type:
Alteration
Building Type:
Single family dwe...
Residential electrical service reactivation/upgrade
2024-10-16
Remove the insides of the old fuse panel. then provide and install a new all in one 100 amp panel on the exterior of the house and re-feed the circuits to the old fuse panel thereby making the old one a junction box. provide and install all new breakers to power the existing circuits. will need to install a new weather head mast flashing guy kit feeders and hub to feed the new panel. ... see more
Valuation:
N/A
Permit #:
R-SERVE-2024-0104
Status:
final
Fee:
$40
Permit Type:
N/A
Building Type:
N/A
424-544-electrical
2024-09-26
Upgrade the existing entire main panel. remove the existing meter base mast feeders and weather head. remove the existing 100 amp ite panel inside of the garage. then provide a new meter base on the exterior of the house with a new weather head mast hub and feeders. provide and install a new 200 amp 30/60 space electrical panel with new breakers to feed the existing circuits inside of... see more
Valuation:
N/A
Permit #:
ELE24-02929
Status:
final
Fee:
$55
Permit Type:
Repair
Building Type:
Single family dwe...
424-544-electrical
2024-10-29
Remove the existing meter base mast feeders and weather head. then provide and install a new all in one 100 amp meter/main panel on the exterior of the house install a new 2 mast hub feeders flashing and weather head. install new grounding by installing new ground rods and bonding of the water pipe if necessary. remove the fuses from the panel that is inside the house and make it beco... see more
Valuation:
N/A
Permit #:
ELE24-01191
Status:
final
Fee:
$55
Permit Type:
Alteration
Building Type:
Single family dwe...
Existing residential electrical (remodel/additions)
2024-04-10
Remove the existing chch 100 amp panel. then provide and install a new 200 amp panel in its place. will need to upgrade the main grounding install a new 200 amp meter base install new feeders install an expansion coupler install a new intersystem ground terminal and refeed all circuits into the new panel. will need to coordinate with idaho power and meridian inspectors for disconnecti... see more
Valuation:
N/A
Permit #:
R-ELCEX-2024-0062
Status:
final
Fee:
$40
Permit Type:
N/A
Building Type:
N/A
Residential electrical service reactivation/upgrade
2024-02-26
Provide and install a new all in one cutler hammer 200 amp meter main panel. remove the existing meter base on the exterior of the house. install a new expansion coupler meter main panel and intersystem bonding device. upgrade the ground wiring to the ufer accommodate the new 200 amp panel. install a new 100 amp breaker to feed the garage panel and reconfigure it to become a subpanel
Valuation:
N/A
Permit #:
R-SERVE-2024-0014
Status:
final
Fee:
$40
Permit Type:
N/A
Building Type:
N/A
424-544-electrical
2024-02-08
Remove the existing zinsco panel that is in the kitchen. then provide and install a new 100 amp breaker panel in its place. will need to ensure that the new panel is set up to be a subpanel. provide and install all new breakers to feed the existing circuits
Valuation:
N/A
Permit #:
ELE24-00333
Status:
final
Fee:
$55
Permit Type:
Repair
Building Type:
Single family dwe...
Residential electrical pool or hot tub
2023-05-25
Install a new dedicated 50 amp 240 volt circuit to power the new hot tub disconnect. from the panel install a new 6/3 home run from the square d panel in the garage into the attic. then bring power out of the attic on the outside of the house and convert wiring inside of a junction box to thhn wiring. install conduit and wiring down the side of the house into the trench to the locatio... see more
Valuation:
N/A
Permit #:
R-ELCPH-2023-0046
Status:
final
Fee:
$80
Permit Type:
N/A
Building Type:
N/A
424-544-electrical
2023-05-05
Replace the existing main electrical panel. will need to remove the existing 100 amp panel and meter base and replace them with new 200 amp versions provide and install a new 200 amp panel with new feeders from the meter base. install a new low voltage bond unit and new expansion joint on the riser. will need to install (3) new 30 amp breakers (1) new 40 amp breaker (5) new 20 amp bre... see more
Valuation:
N/A
Permit #:
ELE23-01328
Status:
final
Fee:
$55
Permit Type:
Repair
Building Type:
Single family dwe...
424-544-electrical
2023-02-16
Demolish wiring as needed and reconnect circuits as needed to ensure existing wiring works through the house after wall is removed and bathroom is removed wire for outlets through the master bedroom to abide by current codes for spacing and these will need to be arc fault protected. wire the new bathroom to have a new exhaust fan wire for double vanity lights a can light over the show... see more
Valuation:
N/A
Permit #:
ELE22-04548
Status:
final
Fee:
$110
Permit Type:
Alteration
Building Type:
Single family dwe...