Want a quote from Electripro, Inc?

We recommend getting 3 quotes for any construction project.
Use our free bidding system to get a quote from Electripro, Inc + 2 more of the best.

Is this your business? Claim now >

Location and Projects

Address
230 Chelsea ST, El Paso, TX, 79905
Use our bidding system to request a quote

Electripro Electrician

Electripro, Inc, 230 Chelsea St, El, TX (Employees: John Wever and Stephen Good) holds a General Contractor license and 1 other license according to the Arlington license board.

Their BuildZoom score of 105 ranks in the top 8% of 222,249 Texas licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Electripro, Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Electripro, Inc Services

Start a project today:

Electripro, Inc Contact Information

Phone: (915) 532-8687 Edit
Address: 230 Chelsea ST, El, TX 79905 Edit

Electripro, Inc El

Quality

105
92nd percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Electripro, Inc has a BuildZoom score of 105, which places them above 92% of 222,249 contractors in Texas.

Activity

9 projects
2025
15 projects
2024
1 project
2022
Our building permit records indicate that Electripro, Inc has worked on at least 25.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

6 projects
Home Additions
5 projects
Commercial Renovations
22 projects
Electrical projects
Analyzing permits over the last 4 years shows that Electripro, Inc mostly works on electrical project and home addition projects.

Pricing

1 project
$100k-$250k
Value Not Public: 21.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Electripro, Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Installation
2025-06-17
Itd will upgrade the existing access controls system controlled by the building owner to the city of arlington's gallagher system and connect to the enterprise software. itd will use all existing wire and power supplies and addition a few new doors to the existing panel boxes. itd will replace the existing panels with gallagher panels
Valuation:
N/A
Permit #:
2025 051937 000 00 FP
Status:
pending review
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2025-06-11
101 w abram st arlington tx 76010 (this location did not show up on the search). we are installing a single access control door and adding to the existing system in city hall. itd will install a reader and door contact and connect to the existing electrified fail secure lever set. itd will program the door into the gallagher enterprise system for the city of arlington
Valuation:
N/A
Permit #:
2025 050083 000 00 FP
Status:
pending review
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2025-06-05
Itd will install six (6) access doors into a new gallagher system that will connect to the existing city of arlington's enterprise system. all door hardware is being provided by the general contractor. itd will just connect to the door strikes or power supplies to trigger the doors release
Valuation:
N/A
Permit #:
2025 047685 000 00 FP
Status:
issued
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2025-06-03
Itd will install a gallagher access control system. all door hardware is being provided by the general contractor. itd will connect to the installed strike or power supply for the doors with electronic pushbars. itd will program the system into the existing enterprise system
Valuation:
N/A
Permit #:
2025 047679 000 00 FP
Status:
pre-application
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2025-03-19
Itd will install a gallagher access control system. we will install new panels as shown on drawings run wire in conduit provided by gc division 26 and connect to door hardware provided by gc division 08 laforce. (laforce submittals are attached as well for the door hardware). itd will install new readers and program the doors to open upon a proper card read. tied into the city enterpr... see more
Valuation:
N/A
Permit #:
2025 022214 000 00 FP
Status:
issued
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Active adult community center - gallagher access control system will be installed to have numerous doors be controlled via the city's enterprise access control system. we will supply 10 panels and 10 power supplies that will power door strikes and electronic lever sets. doors with electronic pushbars will have power supplies at the door (provided by division 08). all locking hardware ... see more
Valuation:
N/A
Permit #:
2025 010781 000 00 FP
Status:
pending review
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2025-04-21
Itd will be installing a gallagher access control system on doors shown in the drawings. the system will tie into the city of arlington's enterprise access control system
Valuation:
N/A
Permit #:
2025 034016 000 00 FP
Status:
pending customer response
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
1717 e randol mill (second floor - new edc office relocation). - we will be installing two gallagher access control doors and tying into the coa's enterprise access control system. we will tie into electrified hinges that are being installed by division 08 in a separate construction project
Valuation:
N/A
Permit #:
2024 108016 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2025-04-28
N nash (15704) has approved a 30 day extension - m nicholls (784) 4/28/25 pd access control upgrade - upgrade the exisitng ccure system to the coa enterprise gallagher system. run new wire use some existing door hardware and replace anything not functioning. addition pushbuttons to any maglock door and ensure free egress
Valuation:
N/A
Permit #:
2024 090264 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Itd will be adding two (2) doors to the existing gallagher access control system. we will install surface strikes egress motions to mask door contacts door contacts and a new reader on each door and run the wire to the existing panel in a closet as shown on the drawings
Valuation:
N/A
Permit #:
2024 086181 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2024-12-17
Fm d niederhaus has approved a 180 day extension - m nicholls 12/16/24 itd will addition the mot east stairwell doors on floors 3-8 to the gallagher enterprise city system. we will confirm all door strikes are failsafe and release upon a general fire alarm. a door contactor is changing out the door lever sets to storeroom function to allow for free egress out into the stairwell and lo... see more
Valuation:
N/A
Permit #:
2024 058799 000 00 FP
Status:
issued
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Fm d niederhaus has approved a 180 day extension - m nicholls 12/16/24 upgrade of existing access control system to the city of arlington's enterprise gallagher system. itd will addition a couple new doors to the system and upgrade all existing doors with new card readers. all existing hardware will be used. itd will run new plenum wire to all doors
Valuation:
N/A
Permit #:
2024 054956 000 00 FP
Status:
issued
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2024-11-10
Coa city hall - public works 2nd floor - five (5) access control door addition to the city gallagher enterprise system. each door will get a t11 reader door strike door contact egress motion to mask the door contact and plenum wire back to a control panel installed in the it room
Valuation:
N/A
Permit #:
2024 040717 000 00 FP
Status:
expired
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2024-10-15
City of arlington - ott cribs 2nd floor eoc access control doors - we will upgrade the two existing doors from the existing system to the coa enterprise gallagher system. a new panel will be installed and new readers and connect to all existing door hardware
Valuation:
N/A
Permit #:
2024 038884 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2024-12-30
City of arlington - parks department. we will install a new gallagher access panel for a single door. we will install a power supply and single door controller in the it room and run wire to the front door. the front door will have a strike installed dc egress motion and reader. the door is free egress out. the system will be programmed into the city of arlington's enterprise access s... see more
Valuation:
N/A
Permit #:
2024 033448 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2024-10-15
City of arlington - chase access control door upgrade. we will change out the control panels and the readers to gallagher equipment to function with the city of arlington enterprise access control system. we will use all existing electronic lever sets wire power supplies door contacts and cabinets
Valuation:
N/A
Permit #:
2024 033432 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Installation
2024-11-08
Environmental services - gallagher access control installation install a new gallagher access system. panel to be installed in the rack in the it closet three doors to be installed. two with door strikes and one double door with maglocks. maglock door to have both a dpdt relay request to exit motion as well as a dpdt pushbuttons. the system will be tied into the city gallagher access ... see more
Valuation:
N/A
Permit #:
2024 014342 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Pd swat - gallagher access control installation. two doors and a new gallagher control panel will be installed. each door will be installed with a gallagher reader egress motion door contact and surface mounted door strike. both doors will wire to a gallagher panel located in the same building and connect to the enterprise gallagher system the city is presently using
Valuation:
N/A
Permit #:
2024 014011 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Arlington water utilities laboratory and maintenance building 7001 u.s. 287 frontage r. arlington tx 76001 we are installing a 16 door gallagher access control system to tie into the cities enterprise system. drawings door schedule and specification sheets will be uploaded
Valuation:
N/A
Permit #:
2024 004094 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A
Fm d niederhaus has approved a 180 day extension - m nicholls 12/16/24 south pd access control upgrade - we will be upgrading the existing access control system to the gallagher enterprise system the city of arlington is using. all existing door hardware will be reused unless replacement is needed shown on drawings
Valuation:
N/A
Permit #:
2024 071525 000 00 FP
Status:
final
Fee:
N/A
Permit Type:
8a-special lockin...
Building Type:
N/A

Similar Contractors See more

License # 24-LP-00528
114
BZ Score
$41.7K
Avg Project
-
Projects
License # 38862
123
BZ Score
$70.3K
Avg Project
-
Projects
License # 28970
113
BZ Score
$36K
Avg Project
-
Projects

Electripro, Inc Reviews

BuildZoom hasn't received any reviews for Electripro, Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Electripro, Inc
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.