Updated: Dec 22, 2025
Location and Projects
Address
Laramie County, WY, 00000
Use our bidding system to
request a quote
Encore Electric
Encore Electric at Laramie County, WY 00000, has a BuildZoom score of 90 and ranks in the top 53% of 1,897 Wyoming contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Encore Electric Contact Information
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Encore Electric Laramie County
Quality
90
47th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Encore Electric has a BuildZoom score of 90, which places them above 47% of 1,897 contractors in Wyoming.
Activity
|
2 projects
|
2025 |
|
1 project
|
2024 |
Our building permit records indicate that Encore Electric has worked on at least
3.0 projects over the past 2 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
3 projects
|
Electrical projects |
Analyzing permits over the last 4 years shows that Encore Electric mostly works on
electrical project
projects.
Pricing
|
1 project
|
$500k-$1mil |
|
1 project
|
$1mil+ |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
1 480v 4000a service feeding (2) 2000a conex's for temporary construction powering off of a new 1mw transformer being set by black hills energy. installation of (1) 600a 208v panel to power 10 office trailers (3) 400a 480v panels and 1 250a 208v panel serving a break tent and site lighting. 124.9v ervice extened from a 6mw step up transformer 13.2 tp 24.9v (meter and installed current... see more
Valuation:
$3,750,000
Permit #:
BP-24-02204
Status:
approved
Fee:
$25,816
Permit Type:
N/A
Building Type:
N/A
480v 2000a service for temporary construction power off of existing 1 mw transformer currently installed onsite. installation of 5-200a panels in the building for construction power a break tent (400a panel) a storage tent (400a panel) temporary heating onsite and 1 100a panel for construction power in the admin building
Valuation:
$850,000
Permit #:
BP-24-00103
Status:
approved
Fee:
$8,079
Permit Type:
N/A
Building Type:
N/A
Temporary power for the commissioning effort. install conduit and wire from black hills meter to the 6mw step up transformer then install conduit to the medium voltage. vault and utilize load break elbows in mh02 to feed the site through the urs
Valuation:
$81,000
Permit #:
BP-22-00564
Status:
approved
Fee:
$1,420
Permit Type:
N/A
Building Type:
N/A
Installation of bopu?s requested sewer flow meter on the equipment pad shown in the attached construction drawings. plans showing the flow meter and the associated manhole were previously reviewed approved and permitted by the city however, bopu has since requested a flow meter change and equipment pad installation which were not shown on the original plans. the equipment/equipment pa... see more
Valuation:
$150,000
Permit #:
BP-22-03285
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Hensel phelps will be transferring two (2) site trailers to encore electric that will remain in place til the encore is complete with their potholing scope of work. encore will demobilize the trailers once complete
Valuation:
N/A
Permit #:
BP-22-01030
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Installation of bopu?s requested sewer flow meter on the equipment pad shown in the attached construction drawings. plans showing the flow meter and the associated manhole were previously reviewed approved and permitted by the city however bopu has since requested a flow meter change and equipment pad installation which were not shown on the original plans. the equipment/equipment pad... see more
Valuation:
N/A
Permit #:
BP-22-03281
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
480v 400a temporary construction power for cys42 project (7mdcs) and teh fos area. this 2500kva transformer will feed trailer trailer town 1 guard shack and the building with construction power
Valuation:
N/A
Permit #:
BP-22-01147
Status:
issued
Fee:
$1,407
Permit Type:
N/A
Building Type:
N/A
Install a new fire alarm system throughout the building
Valuation:
$1,375,000
Permit #:
BP-19-00120
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Extend electrical from nearest ground box. install conduit and wire to sams club sign. install an electrical meter and a 20 amp fused disconnect. from the disconnect install conduit and wire to power new sign. location of ground box power has been coordinated with black hills energy
Valuation:
$6,000
Permit #:
BP-20-04755
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Disconnect electrical and remove conex container. break and remove concrete pad under conex concrete pad under transformer and concrete sidewalk leading to the pad. break and remove (2) freestanding 20'x20 concrete pads. this work is in reference to permit # bp-18-00434
Valuation:
N/A
Permit #:
BP-20-01231
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Temporary power for future cys08 data center per attached electrical 1-line drawing. demolish of existing concrete pad and sidewalk that is in the way of temp power routing. 11/30/20 adtl work 1: addition a 500kva isolation transformer to our temp power set up for cys08 project
Valuation:
N/A
Permit #:
BP-20-01138
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove 1200 amp temporary power connex and replace with permanent panels disconnects and transformers
Valuation:
N/A
Permit #:
BP-22-00817
Status:
complete
Fee:
$955
Permit Type:
N/A
Building Type:
N/A
Set up 200 amp meter housing and 200 amp 120/240 volt panel to feed 2 connex's
Valuation:
$8,200
Permit #:
BP-21-00604
Status:
approved
Fee:
$167
Permit Type:
N/A
Building Type:
N/A
Connection to clf&p utility transformer on east side of parking lot. pipe underground to out power conex distribute power to construction trailers on the east half of the parking lot pipe underground to the west side of the parking lot and distribute power to construction trailers on west side
Valuation:
$21,050
Permit #:
BP-15-02226
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removal of historic light fixtures de-energize lighting circuits lockout tag out of the associated breakers removal of the light fixtures cap and make safe of the lighting circuits
Valuation:
$52,500
Permit #:
BP-16-00412
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New fire alarm for the remodels space
Valuation:
$65,101
Permit #:
BP-17-00687
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install one five-plex construction (3000 sq ft) and two double-wide construction trailers (1200 sq ft each). connect to temporary construction power. the factory-installed plumbing will be deactivated and labeled not for use
Valuation:
N/A
Permit #:
BP-21-00362
Status:
closed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install fire alarm in new block house and tie into existing system
Valuation:
$2,837
Permit #:
BP-20-04584
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
No Description Available
Valuation:
N/A
Permit #:
BP-15-01790-05
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
No Description Available
Valuation:
N/A
Permit #:
BP-25-01332
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial
Similar Contractors See more
License # EC 02653
Cheyenne, WY
107
BZ Score
$8K
Avg Project
-
Projects
License not required
Cheyenne, WY
108
BZ Score
$4.3K
Avg Project
-
Projects
License # CT-13-02465
Cheyenne, WY
107
BZ Score
$5.5K
Avg Project
-
Projects
Encore Electric Reviews
BuildZoom hasn't received any reviews for Encore Electric. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Encore Electric License info
License Not Required
| Status | Not Required |
- BuildZoom verified in September, 2022 that this contractor does not need a license to be a electrician in Wyoming.
This is a sample of licensing data; click here to access a complete history.
90
BuildZoom Score
20
Permits
- Building permit records show that Encore Electric has worked on 20 permitted projects.