We'll help you find the right contractor.

Share your project details and we'll reach out to Engineering Consultants, Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >

Location and Projects

Address
303 Federal Way, Boise, ID, 83705
Use our bidding system to request a quote

Engineering Consultants, Inc

Engineering Consultants, Inc, 303 Federal Way, Boise, ID holds a Building Unlicensed license according to the Idaho license board.

Their BuildZoom score of 106 ranks in the top 7% of 53,194 Idaho licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Engineering Consultants, Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Engineering Consultants, Inc Services

Start a project today:

Engineering Consultants, Inc Contact Information

Phone: (208) 376-9820 Edit
Address: 303 Federal Way, Boise, ID 83705 Edit

Engineering Consultants, Inc Boise

Quality

106
93rd percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Engineering Consultants, Inc has a BuildZoom score of 106, which places them above 93% of 53,194 contractors in Idaho.

Activity

5 projects
2025
17 projects
2024
35 projects
2023
Our building permit records indicate that Engineering Consultants, Inc has worked on at least 57.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

8 projects
Commercial Renovations
5 projects
Home Additions
Analyzing permits over the last 4 years shows that Engineering Consultants, Inc mostly works on commercial renovation and home addition projects.

Pricing

1 project
$1mil+
Value Not Public: 55.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Engineering Consultants, Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
601-602-fire alarms
2023-10-02
Replacement of failing panel (dmp-xr250) with (dmp-xr550) all fa components are compatible since the panel is being replaced by the same manufacturer. this permit is not attached to a building permit and the scope of work is to replace the facp that will be compatible with all existing devices if any devices are not combatable then they will need to do a full system upgrade. no plan r... see more
Valuation:
N/A
Permit #:
FIR23-00246
Status:
final
Fee:
$175
Permit Type:
Repair
Building Type:
Commercial
601-602-fire alarms
2023-01-06
Relocate existing notification for tenant improvement. the scope of work of relocating notification devices (3) 2 are now in singular use offices that would not require the notification devices but they are correctly spaced for the visible coverage areas 1 in the lobby that is correctly spaced for the area shown. this permit is attached to naf22-00043 no plan review report provided
Valuation:
N/A
Permit #:
FIR22-01106
Status:
final
Fee:
$210
Permit Type:
Alteration
Building Type:
Office
601-602-fire alarms
2024-01-12
Fire sprinkler monitoring system. this permit is attached to bld21-04637 and for this r3 occupancy only the monitoring of the sprinkler system is required. due the the building being fully sprinklered then only one pull station is required and the dact is internal to the facp as to why not shown on the plans. no plan review report provided. 11/22/22 as-builts reflect the change of pan... see more
Valuation:
N/A
Permit #:
FIR22-01020
Status:
final
Fee:
$233
Permit Type:
New
Building Type:
Multiple family d...
601-602-fire alarms
2022-10-18
Alter and extend existing fa system into remodeled tenant improvement. this permit is attached to bld22-02308 the work in the scope of work area will include 7 new smoke detectors and 2 new notification devices in the hallway 107. corridor spacing is being used in the hallway and the smoke detectors are within 21ft to all points on the applicable ceilings. no plan review report provided
Valuation:
N/A
Permit #:
FIR22-00904
Status:
final
Fee:
$247
Permit Type:
Alteration
Building Type:
Office
601-602-fire alarms
2022-04-15
Demolish pull and h/s not required per code. this permit is attached to bld21-04605 the pull and notification device were part of an old system this occupancy type and load does not meet the requirements for a manual fire alarm system or occupant notification. building is fully sprinklered
Valuation:
N/A
Permit #:
FIR22-00129
Status:
final
Fee:
$175
Permit Type:
Alteration
Building Type:
Office
601-602-fire alarms
2022-03-04
Alter and extend notification for coverage on the mezzanine. there are a total of 8 new horn/strobe devices with a 75 candela being added and this permit is attached to bld20-04730. this is a s1 occupancy and does not require occupant notification but need to be installed per code requirements. 75cd ceiling mounted devices have a 44x44ft coverage. the as-builts show the addition of a ... see more
Valuation:
N/A
Permit #:
FIR22-00015
Status:
final
Fee:
$245
Permit Type:
Addition
Building Type:
Storage
601-602-fire alarms
2022-03-29
Provide notification within the tenant improvement space. 4 explosion proof strobes to be installed in the spray booths. this is associated with bld21-03153 plan report provided. plan mod 2/7/2022, show the addition of 2 duct detectors with relays. plan mod show the addition of two duct detectors and relays
Valuation:
N/A
Permit #:
FIR21-00939
Status:
final
Fee:
$245
Permit Type:
Alteration
Building Type:
Commercial
601-602-fire alarms
2022-02-25
Provide combo burg/fa system with full area detection manual pulls and notification. this permit is attached to bld20-02154 there is a total of 22 initiating devices and 14 notification devices. this building is not sprinklered designer has provided a document for how the heat spacing was acquired with what deductions were used.as-built shows the additional heats that were not shown o... see more
Valuation:
N/A
Permit #:
FIR21-00831
Status:
final
Fee:
$346
Permit Type:
New
Building Type:
Commercial
601-602-fire alarms
2023-04-04
3 duct detectors are being provided with the hvac units monitor them with the facp this work is not associated with a building permit. no plan review report provided
Valuation:
N/A
Permit #:
FIR22-00612
Status:
final
Fee:
$189
Permit Type:
Alteration
Building Type:
Office
601-602-fire alarms
2023-11-16
Replace existing fire alarm system with a new voice/evac system. fire sprinkler monitoring and hvac shutdown. upgrade agreement in place for future elevator upgrade to allow all elevator emergency functions
Valuation:
N/A
Permit #:
FIR23-00394
Status:
final
Fee:
$532
Permit Type:
Alteration
Building Type:
Commercial
601-602-fire alarms
2023-05-30
Provide fire sprinkler monitoring system. this permit is attached to bld20-04141 and this install will include a pull station smoke detector facp (dact internal) flow switch and tamper switch
Valuation:
N/A
Permit #:
FIR22-00474
Status:
final
Fee:
$198
Permit Type:
New
Building Type:
Multiple family d...
601-602-fire alarms
2023-06-09
Provide fire sprinkler monitoring system. this permit is attached to bld20-04142 and this install will include a pull station smoke detector facp(dact internal) flow switch tamper switch
Valuation:
N/A
Permit #:
FIR22-00473
Status:
final
Fee:
$198
Permit Type:
New
Building Type:
Multiple family d...
601-602-fire alarms
2022-09-14
Change candela on existing strobe for visual coverage no plan review report provided 2 visual notification devices are now at 75cd that allow a coverage area of 45x45 (wall mounted coverage pulled from nfpa 72 18.5.5.5.1)
Valuation:
N/A
Permit #:
FIR22-00796
Status:
final
Fee:
$175
Permit Type:
Alteration
Building Type:
Industrial
601-602-fire alarms
2023-04-26
Provide fire sprinkler monitoring. 1 smoke 1 pull 3 flow switches 5 tamper switches also see comments for r2 requirements
Valuation:
N/A
Permit #:
FIR21-00925
Status:
final
Fee:
$242
Permit Type:
New
Building Type:
Multiple family d...
601-602-fire alarms
2023-02-13
Provide manual fire alarm system with full area detection and hvac shutdown. building is not fire sprinklered
Valuation:
N/A
Permit #:
FIR22-00793
Status:
final
Fee:
$210
Permit Type:
New
Building Type:
Office
601-602-fire alarms
2020-05-21
Alter extend notification in new tenant improvement. troy stated a permit is required to replace nac panels as the entire building notification will not sync. will calcs for both panels with as-builts. this work is associated with building permit bld20-01060
Valuation:
N/A
Permit #:
FIR20-00300
Status:
final
Fee:
$310
Permit Type:
Alteration
Building Type:
Commercial
601-602-fire alarms
2020-10-30
Facp replacement due to 4 duct detectors added for the tenant improvement. system includes sprinkler monitoring amonia monitoring smoke detection for door holder release and duct detection. this work does not appear to be associated with a building permit
Valuation:
N/A
Permit #:
FIR20-00380
Status:
final
Fee:
$295
Permit Type:
Alteration
Building Type:
Commercial
601-602-fire alarms
2023-04-26
Provide fire sprinkler monitoring.1 pull station 3 flow switches 1 smoke detector 5 tamper switches
Valuation:
N/A
Permit #:
FIR21-00921
Status:
final
Fee:
$242
Permit Type:
New
Building Type:
Multiple family d...
601-602-fire alarms
2020-07-07
Replace fire alarm panel and bring building fa system up to code. system includes some smoke detectors manual alarms a pull stations sprin kler monitoring and duct smoke detection. this work is not associated with a building permit
Valuation:
N/A
Permit #:
FIR20-00262
Status:
final
Fee:
$198
Permit Type:
Replacement
Building Type:
Commercial
601-602-fire alarms
2021-01-20
Replacement of facp and associated initiating devices. notification and nac panel to remain notification relocated for full visual coverage in tenant improvement and common area
Valuation:
N/A
Permit #:
FIR20-00784
Status:
final
Fee:
$282
Permit Type:
Alteration
Building Type:
Office

Similar Contractors

License # AEC21853
110
BZ Score
$1
Avg Project
-
Projects
License # RCE-41458
108
BZ Score
$277K
Avg Project
-
Projects
License # P-15386
107
BZ Score
-
Avg Project
-
Projects

Engineering Consultants, Inc Reviews

BuildZoom hasn't received any reviews for Engineering Consultants, Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Engineering Consultants, Inc
1 Rate this engineer
Click stars to rate
2 Provide a detailed review of this engineer.