Share your project details and we'll reach out to
Environmental Works
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Environmental Works offers responsible and cost effective solutions in the environmental and construction industries, including oil tank removal, radon testing and mitigation, and sewer repair.
From BuildZoom: Environmental Works, 22820 NE Sandy Blvd, Fairview, OR holds a Plumbing license and 1 other license according to the Oregon license board.
Their BuildZoom score of 116 ranks in the top 2% of 62,733 Oregon licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Environmental Works, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
San conn: 145 lf of 8 (vsp) main (approx. d=9') in (se 16th ave). contractor connect to existing branch per standard p-262 (approx. l=18 d=9') located approx. 90 from ds smh (acy722). contractor must verify depth/location and downstream connection point to public system in the field. contact x31026
Contractor to abandon sewer lateral by installing a concrete plug at the interface of the privately maintained pipe and publicly maintained pipe. concrete plugs installed at curb and at 911's lateral. 392 lf of 8 csp main approx. d=9 in ne oneonta st lateral located approx. 283 from ds smh aak840 d=9 per cop standard con spec 00490.43(b)(2)(5) 490.44. contact x31026
Cut and remove the lavatory drain connection and a section of main drain stack. the toilet will be set aside and the toilet flange cut and removed. the drain and toilet flange will be replaced with abs pipe and fittings. i will stub-out a new drain connection for the lavatory sink and reset the toilet. once the wall and vanity has been put back i will reconnect the lavatory drain and ... see more
San conn: 194 lf of 10 (vsp) main in (ne lawrence ave). contractor to install 10"x6 tee into 10 main and prepare 6 branch to property per standard p-262. contractor must verify depth/location and downstream connection point to public system in the field. contact x31026
San conn: 392 lf of 8 csp main approx d=9 in ne oneonta st. contractor to install 8"x6 tee into 8 main and prepare 6 branch to property per standard p-262. contractor to verify all depths and connections in field. contact x31026
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location pipe bursting. contractor must verify depth/location and downstream connection point to public system in the field
San conn: 260 lf of 16 varies main approx d=9.40 in se 11th ave. contractor shall building new branch per standard p-262 and core drill tap 16 sewer. contractor to verify all depths and locations in field. contact x31026
San conn: 273 lf of 48 mono main approx d=18 in se 72nd ave. contractor shall install a 6 c/o behind foc per standard p-257 and building new 6 branch per standard p-262 and connect at new bom tap of 48 main/bom install 48 by 6 fitting. contractor to verify all depths and locations in field. contact x31026
Contractor to abandon sewer lateral by installing a concrete plug at the interface of the privately maintained pipe and publicly maintained pipe. concrete plugs installed at property and curb where lateral is located. 273 lf of 48 mono main approx. d=18 in se 72nd ave lateral located approx. 45 from ds smh abv991 d=10 per cop standard con spec 00490.43(b)(2)(5) 490.44. contact x31026
Contractor to abandon sewer lateral by installing a concrete plug at the interface of the privately maintained pipe and publicly maintained pipe. concrete plugs installed at public mh. 148 lf of 8 pvc main (approx d=6.1') in sw menefee dr. per cop standard con spec 00490.43(b)(2)(5) 490.44. contact x31026
San conn: 263 lf of 64"x 96 brick main approx d=22 to bottom of main in ne thompson st. contractor shall building new branch per standard p-262 and connect at new bom tap of 64"x 96 main. contractor to verify all depths and locations in field. contact x31026
Contractor to connect private lateral to existing public lateral in alley. public main (aam263-aam261) lateral connection per city standard p-262; pbot inspect connection to public lateral (burst/sleeve). contractor must verify depth/location and downstream connection point to public system in the field
Contractor to connect private lateral to existing public lateral in alley. public main (aam659-aam636) lateral connection per city standard p-262; pbot inspect connection to public lateral (burst). contractor must verify depth/location and downstream connection point to public system in the field
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location bursting/sleeving. contractor must verify depth/location and downstream connection point to public system in the field
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location (burst/sleeve). contractor must verify depth/location and downstream connection point to public system in the field
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location (burst/sleeve). contractor must verify depth/location and downstream connection point to public system in the field
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location trenching sleeving. contractor must verify depth/location and downstream connection point to public system in the field
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location (burst/sleeve). contractor must verify depth/location and downstream connection point to public system in the field
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location trenching. contractor must verify depth/location and downstream connection point to public system in the field
Contractor to replace existing lateral from property line to face of curb per city standard p-262; pbot note location trenching. contractor must verify depth/location and downstream connection point to public system in the field
Valuation:
N/A
Permit #:
2025-038810-000-00-UR
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Environmental Works Reviews
BuildZoom hasn't received any reviews for Environmental Works. Click here to be alerted when reviews are posted about them.
BuildZoom verified this license was active as of July 2026.
Verify this license's status for Environmental Works at the Oregon Building Codes Division.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
License #
185781
Status
Active
State
Oregon
Business Type
Limited Liability Company
When BuildZoom last verified this license, it had an expiration date of December, 2024. Check the current license status of Environmental Works with the Oregon Construction Contractors Board (CCB)
This is a sample of licensing data; click here to access a complete history.