Firecall at 15744 CALIFORNIA AVENUE, Paramount, CA 90723, held a Electrician license (#649275) with the California contractors license board with an expiration date of 07-31-1994. We last verified the license was expired on 05-22-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
New warehouse addition with rack storage existing pump @ 0 gpm @ 121 psi 1211 gpm @ 100 psi & 2000 gpm @ 68 ps i. design criteria: class iii commodity 22 max. storage ht. 35 gpm/sq ft over 2000sq. ft addition 1 level of in rack sprinkler. see plan for more detail on design criteria
System upgrade for storage of piled plastic pallets. new heads branch lines and cross main. system design per tyco ultra k17 ul listing. coa of listing under application comments. system supplied by existing fire pump system at 22 psi min per head with 15 heads flowing and 500 gpm hose demand
Sherman oaks galleria standpipes fires sprinklers+wate curtain area mto. phase1b& wb. phase 1. c.o.a. building. shall not be occupied until fully sprinklered. scope of work : installation of stand pipes fire sprinklers in common areas+ water curtain heads per variance & 3 bulk mains
Installing 1301 sprinkler heads. basement parking theater, retail& restaurants. scope of work. installation of complete class-1 standpipe system. protect all common areas with a complete fire sprinkler system floors 1, 2, 3 &4. provide mains with plugged outlets for future tenants floors 1, 2, 3&4. design criteria. parking level (basement) o.h. group 1. first & second floors o.h. ii (... see more
Fire warning system for a charter middle school-one set of fire alarm plans covering the fa system for the high school ( 06041-10000-16841 ) and for the middle school (separate buildings) with one fa panel installed in the high school building
Install standpipe system and fire pump for 9-story type 1 office building converted into 314 unit 10-story apartment building per adapted reuse ordinance. for fire protection sprinklers in floors 2 thru 7 see permit #04043-10000-00900
Fire warning system for a charter high school-one set of fire alarm plans covering the fa system for the high school and for the middle school (separate buildings) with one fa panel installed in the high school building
Relocate (3) heads in 8th floor lobby south 2 in 6th floor looby 2 in 9th floor lobby south 2 in 4th floor lobby south 2 in 3rd floor. lobby south and 2 in b-2 level lobby south (for a total of 13 heads)
Revision addition 23-fire sprinkler heads see plan check/permit 05043-10000-01451. (sprinkler system for 5 story building. fire pump & stand pipe system 6 detector check valve backflow preventer required..)
Electrical work for fire alarm system replacement for all 8 floors of the hoffman hall in usc. **this is a supplemental application for delta 1 changes to a previous approved set of plans.**
Revision to previously approved fire alarm plan: changed annunciator panel face and use different type heat detectors. lafd stamp approved revision. electrical permit is existing
Install underground water and sewer lines. engineering record no. required in order to connect to public sewer (otherwise dry sewer only). contact public works at 818-756-8421
Supplemental permit to collect fees for (1) additional inspections. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for (2) additional inspections. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for (1) additional inspections. this permit does not authorize any additional work or extend the expiration date of the original permit
Supplemental permit to collect fees for (2) additional inspections. this permit does not authorize any additional work or extend the expiration date of the original permit
Install new fire devices in the villa building. the devices will be connected to the alarm system in the grammar building. see application # 02041-10000-16488
Fire sprinkler for rack storage in an existing sprinklered buidling. install one level of in-rack sprinklers per 1995 nfpa 231c. ceiling sprinkler system is existing
Fire alarm system for new 3 story office/retail/restaurant building (92, 608 s.f.) with subterranea pkg (46, 368 s.f.) shell only. this building is known as building a
Install new sprinkler system in floors 2 thru 7 ( 2304 new heads). for installation of fire pump and modifications of existing standpipe see #04043-20000-02102
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Firecall at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.
Inactive License
License #
276650
Status
Inactive
State
California
Type
Low Voltage Systems, Electrical
Business Type
Corporation
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Firecall at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.