We'll help you find the right contractor.

Share your project details and we'll reach out to GL Hunt Foundation Repair so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started

Location and Projects

Address
4021 Hwy 377 S, Fort Worth, TX, 76116
Use our bidding system to request a quote

GL Hunt Foundation Repair Construction

G.L. Hunt Foundation Repair was founded in April of 1987. At that time Gary Hunt worked with his father Bill Hunt in the Dallas/Fort Worth area doing structural repair on houses throughout the DFW Metroplex. Today, Gary Hunt runs the family office, which is still based out of Fort Worth.

With his family’s forty years of construction experience and knowledge, he leads this company into continued and ongoing success in the foundation repair industry.

G.L. Hunt has an unique business philosophy and standard that sets it apart from all its competitors. The company employs team members who are experienced construction experts that take pride in the quality of service and work they provide. Bill Hunt built this business on the concept that a handshake while looking someone in the eye constitutes a binding contract. This set the tone for the culture of G.L. Hunt that still lives strong today.

From BuildZoom: GL Hunt Foundation Repair, 4021 Hwy 377 Hwy S, Fort Worth, TX (Owned by: Samantha Hernandez) holds a General Contractor License license and 32 other licenses according to the Texas license board.

Their BuildZoom score of 115 ranks in the top 2% of 222,249 Texas licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring GL Hunt Foundation Repair, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

GL Hunt Foundation Repair Services

Start a project today:

GL Hunt Foundation Repair Contact Information

Phone: (817) 222-9253
Address: 4021 Hwy 377 S, Fort Worth, TX 76116

GL Hunt Foundation Repair Fort Worth

Quality

115
98th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
GL Hunt Foundation Repair has a BuildZoom score of 115, which places them above 98% of 222,249 contractors in Texas.

Activity

9 projects
2026
678 projects
2025
596 projects
2024
440 projects
2023
Our building permit records indicate that GL Hunt Foundation Repair has worked on at least 1723.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

207 projects
Home Additions
57 projects
New Constructions
13 projects
Commercial Renovations
416 projects
Multi-room remodels
Analyzing permits over the last 4 years shows that GL Hunt Foundation Repair mostly works on multi-room remodel and home addition projects.

Pricing

25 projects
< $5k
120 projects
$5k-$20k
7 projects
$20k-$50k
5 projects
$50k-$100k
1 project
$100k-$250k
Value Not Public: 1537.0 projects
The typical size of their permits is approximately $8,693. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by GL Hunt Foundation Repair

Sort by: Notable Notable | Date Date | Job Value Job Value
Repairs & alterations (residential)
2025-11-24
2914 windsor avenue waco tx 76708 • installing 4 total pilings (1 exterior 3 breakouts). • reset/re-shim 1357 sqft of the foundation with steel to improve leveling. • excavate 218 sqft of the structure. • create 1 access for excavation. • adjust or straighten 45 lf of existing beam. • repair 1 corner pop. • repair 3 lf of spawling concrete
Valuation:
$12,633
Permit #:
25-00986-BLDR
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair list of foundation repairs 1. install (9) new exterior steel pressed piers. 2. install (1) new exterior interior steel “breakout” pressed pier. 3. use steel shims for all final vertical adjustments. foundation repair details- partial yes slab on grade yes 10 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with i... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100830
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair 1. install (10) new exterior steel hybrid pressed piers. 2. install (2) new exterior interior steel hybrid “breakout” pressed piers. 3. use steel shims for all final vertical adjustments. foundation repair details- full or partial yes slab on grade yes 12 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with ib 1... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100836
Status:
issued
Fee:
$52
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair: partial slab on grade repair; 10 of piers replaced; 1000 sq ft of work done; skirting removed n no other remodeling work being performed. **must comply with udc and irc. must comply with ib 172. **engineers letter required to clear foundation inspection. -removal/repair/replacement of skirting: requires final inspection by city inspector for venting subfloor acces... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100835
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair 1. install (6) new exterior steel pressed piers. 2. install (3) new exterior interior steel “breakout” pressed piers. 3. use steel shims for all final vertical adjustments. foundation repair details- partial yes slab on grade yes 9 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with ib 172. no skirting & no oth... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100834
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair foundation repair details- partial yes slab on grade yes 18 pier & footings no wood sill no beam no joist must comply with udc and irc. must comply with ib 172. no skirting & no other remodeling work being performed. **engineers letter required to clear foundation inspection**m.carranza** **copy of application must be available at job site with permit** **removal/r... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100833
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair 1. install (25) new exterior concrete pressed piers. 2. install (2) new exterior interior concrete breakout pressed piers. 3. create a 23 tunnel to install (4) interior concrete pressed piers. 4. use steel shims for all final vertical adjustments. foundation repair details-partial yes slab on grade yes 31 pier & footings no wood sill #lf no beam # lf no joist # lf ... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100832
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair foundation repair: partial slab on grade repair; 12 piers replaced; 1200 sq ft of work done; skirting removed n no other remodeling work being performed. **must comply with udc and irc. must comply with ib 172. **engineers letter required to clear foundation inspection. -removal/repair/replacement of skirting: requires final inspection by city inspector for venting... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100825
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-04
; foundation repair 1. install (8) new interior exterior steel “breakout” pressed piers. 2. use steel shims for all final vertical adjustments. foundation repair details- partial yes slab on grade yes 8 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with ib 172. no skirting & no other remodeling work being performed. **engineers l... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100824
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Foundation repair permit
2025-04-03
; amend scope of work. changed from 12 piers to 13 to match letter. ** aj** foundation repair foundation repair details- partial yes slab on grade yes 13 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with ib 172. no skirting & no other remodeling work being performed. **engineers letter required to clear foundation inspection. **... see more
Valuation:
N/A
Permit #:
REP-FND-PMT25-35100821
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-07-01
; foundation repair: foundation repair details- partial yes slab on grade yes 12 pier & footings no wood sill (beam) no joist must comply with udc and irc. must comply with ib 172. no skirting & no other remodeling work being performed. **engineers letter required to clear foundation inspection**m.carranza** **copy of application must be available at job site with permit** **removal/r... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35008044
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-07-01
; foundation repair: foundation repair details- partial yes slab on grade yes 8 pier & footings no wood sill (beam) no joist must comply with udc and irc. must comply with ib 172. no skirting & no other remodeling work being performed. **engineers letter required to clear foundation inspection**m.carranza** **copy of application must be available at job site with permit** **removal/re... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35008021
Status:
issued
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-06-27
; foundation repair -engineer’s letter required to clear foundation inspection. -copy of application must be available at job site with permit -removal/repair/replacement of skirting: requires final inspection by city inspector for venting subfloor access and drainage (in addition to engineer’s letter noted above). -slab on grade- the letter should specifically indicate that drainage ... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35007839
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-06-27
; foundation repair -engineer’s letter required to clear foundation inspection. -copy of application must be available at job site with permit -removal/repair/replacement of skirting: requires final inspection by city inspector for venting subfloor access and drainage (in addition to engineer’s letter noted above). -slab on grade- the letter should specifically indicate that drainage ... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35007879
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-06-25
; foundation repair 06/26/25 foundation repair details- partial 1300 sq ft yes slab on grade yes pier and footings- 13 piers no wood sill (#) lf no beam (#) lf no joist (#) lf must comply with udc and irc. must comply with ib 172. no skirting and no other remodeling work being performed. -engineer’s letter required to clear foundation inspection. -copy of application must be available... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35007665
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-06-17
; foundation repair install (7) new exterior interior steel hybrid “breakout” pressed piers. 2. use steel shims for all final vertical adjustments foundation repair details- partial yes slab on grade yes install 7 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with ib 172. no skirting & no other remodeling work being performed. **... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35007248
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-06-10
; foundation slab on grade work summary: foundation repair foundation repair details - partial yes slab on grade no pier and footings no wood sill no beam no joist must comply with udc and irc. must comply with ib 172. no skirting and no other remodeling work being performed. -slab on grade- the letter should specifically indicate that drainage meets the minimum requirements for the c... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35006879
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-05-30
; foundation repair foundation repair details- partial yes slab on grade yes 13 pier & footings no wood sill no beam no joist must comply with udc and irc. must comply with ib 172. no skirting & no other remodeling work being performed. **engineers letter required to clear foundation inspection**m.carranza** **copy of application must be available at job site with permit** **removal/r... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35006392
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-05-30
; foundation repair install (13) new exterior concrete pressed piers. 2. install (5) new exterior interior concrete “breakout” pressed piers. 3. create a 4 trench. 4. use steel shims for all final vertical adjustments foundation repair details- partial yes slab on grade yes 18 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with ib... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35006379
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Minor building repair application
2025-05-30
; foundation repair install (2) new sonotubes. 2. remove (4) existing sonotubes. 3. reset and re-shim 1041 sf of understructure. 4. use steel shims for all final vertical adjustments foundation repair details-partial no slab on grade yes 6 pier & footings no wood sill #lf no beam # lf no joist # lf must comply with udc and irc. must comply with ib 172. no skirting & no other remodelin... see more
Valuation:
N/A
Permit #:
REP-MBR-APP25-35006388
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A

GL Hunt Foundation Repair Reviews

BuildZoom hasn't received any reviews for GL Hunt Foundation Repair. Click here to be alerted when reviews are posted about them.
Please write a review about GL Hunt Foundation Repair
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.