Cont'd- circuits installation of light fixtiures and site lighting.lightning protection system. low voltage conduit and wiring for a tele/data system. 62 electrical drawings and 24 tel/dat drawings. o8 nec. : electrical work-new 14 story 450 bed dorm consisting of new 15kv 4000a service. work includes lighting and power branch -cont'd-
Education areas. work includes new lighting addition of electrical panels (to be fed from existing service) to support classrooms and exhibit spaces. scope also includes new security system fire alarm modifications (fire alarm to be separate permit
Exterior dining terrace area (not including pool area) new conduit & wiring for a snack area new & relocated lighting power & low voltage as per 2008 nec (cc district)no service work on this permit - 1 speaker strobe devices removed and replaced as per nfpa72
Wire and install new tele/data security controls electrical power and lighting for 242 existing apartment this permit includes come electrical demolish on an existing service as per 2008 nec (cc district)no service work on this permit - wire and install various fire alarm devices throughout building as per nfpa72
Low voltage catv/tele data cabling power hvac controls receptacles lighting and lighting controls with security cabling and equipment is by others as per 2008 nec (cc district) replace/relocate fire alarm wiring and devices on existing fire alarm system as per nfpa72
New 100 amp sub panel 208y 120v install new lighting and power devices. empty conduits for low voltage systems as per 2008 nec. (cc district)***no fire alarm***
Furnish and install conduit and wire for new service, cabling for recepts, equipment and lighting as detailed on the drawings, conduit for telecomm as per 2008 nec (cc district) furnish and install cabling and devices for complete fire alarm system as per nfpa72 ***separate permit required for emergency response radio coverage system prior to the issuance of a cerificate of occupancy***
Renovation of an apartment building. new 100 amp electrical panel feeder lighting devices and tele/catv in every unit. remove and reinstall existing corridor light fixtures per 2008 nec (apt bldg)relocate existing fa in units per nfpa 72
All electrical lighting power and recep devices for hotel with 332 sleeping units a restaurant and a commercial space w/accessory parking data & security conduits only 54 electrical drawings and 37 fire alarm drawings per nec 2008 install compete fire alarm system per nfpa-72
Renovation of an apartment building new 100 amp electrical panel feeder lighting devices and tele/cable in every unit. remove and reinstall corridor lighting as per 2008 nec (cc distrct)relocate existing fa in units per nfpa 72
Renovation of an existing office space light fixtures recepts switches feeder services from lanlord electrical room tonew panel in the renovated space as per nec 2008 (west district) install new fire alarm devices as per nfpa72
Install new outdoor ht service wiring of 56 apts including lights receptacles switches hot water heaters air handlers common area light & power 13 condenser to be located on the roof exhaust fans on roof tele/data coax wiring in the apts as per 2008nec (cc district). complete fire alarm system as per nfpa72
Fa tamper/flow monitor modules for apts, relocate existing fa in apts, new 100a electrical panels, feeder, lighting, devices, tele/catv, corridor lighting in apts.new 15kv-208 roof top substation and demolish of some existing apts feeder wiring as needed per 2008 nec & nfpa 72(high rise)
Mixed use building fl 2-26 will be office to be fit out on separate permit 29-46 will have 268 apts 28th to be amenity floor electrical work to include core & shell power & lighting & branch wiring, also a new dual 15kv peco service per 2008 nec (mixed use)
Wire and install 3 new panels to feed a temp structure to house a poker room at sugarhouse install receptacles lighting, teledata security lightning protection and grounding as per 2008 nec (east district) install on fa panel and associated devices for the temp poker room as per nfpa72
This electrical permit is for all low voltage audio visual work for the 30th and 31st floors.this area is fitness, pool and social area for the the sterling residence. installation to comply with articles 300.21 300.22 725 & 800 of the 2008 nec
New 2-4000amp 480v 3phase & install commercial wiring for new building and parking lot including grounding, lighting protection, power, lighting and controls per 2008 nec (office space)install fa system per nfpa 72
25th floor (marketing suite) - interior electrical alterations to include installation of (12)existing fixtures with a new home run using circuit #26 from pp-25a panel - the installation will comply with the 2008 nec
BuildZoom has not verified this license since August, 2015.
Verify this license's status for Gordon Group Electric Co at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
Inactive License
HIC #
34EB00892800
Status
Inactive
State
New Jersey
Type
Electrical Business Permit
According to the New Jersey Department of Law & Public Safety, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Gordon Group Electric Co at the New Jersey Department of Law & Public Safety.
This is a sample of licensing data; click here to access a complete history.