Updated: Jul 07, 2026
Location and Projects
Address
Jackson, MI, 49203
Use our bidding system to
request a quote
Harvest Energy Solutions Solar Contractor
Harvest Energy Solutions, Jackson, MI (Employees: Daniel Carmichael, Joel Tatum, and Katina H Baker) holds a license and 4 other licenses according to the Illinois license board.
Their BuildZoom score of 107 ranks in the top 6% of 167,179 Michigan licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Harvest Energy Solutions, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Harvest Energy Solutions Contact Information
Phone Number: (517) 788-8800
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Harvest Energy Solutions Jackson
Quality
107
94th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Harvest Energy Solutions has a BuildZoom score of 107, which places them above 94% of 167,179 contractors in Michigan.
Activity
|
6 projects
|
2025 |
|
13 projects
|
2024 |
|
10 projects
|
2023 |
Our building permit records indicate that Harvest Energy Solutions has worked on at least
29.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
3 projects
|
Commercial Renovations |
|
3 projects
|
Home Additions |
|
25 projects
|
Solar installations |
Analyzing permits over the last 4 years shows that Harvest Energy Solutions mostly works on
solar installation
and home addition
projects.
Pricing
|
1 project
|
$5k-$20k |
|
4 projects
|
$20k-$50k |
|
2 projects
|
$50k-$100k |
|
1 project
|
$100k-$250k |
|
2 projects
|
$250k-$500k |
|
1 project
|
$500k-$1mil |
|
1 project
|
$1mil+ |
The typical size of their permits is approximately $90,104. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
Building Permits by Harvest Energy Solutions
This is a sample of this contractor's permits. Click here to access their complete permit history.
Install carport solar generation systems consisting of (356) 545w modules and a 36 50 and 60kw inverter; and interconnecting with a line-side tap in the customer-owned 800a main service panel. r-4 zoning commercial use
Valuation:
$568,900
Permit #:
PB240628
Status:
issued
Fee:
N/A
Permit Type:
Commercial addition
Building Type:
N/A
Install roof-mounted solar generation system. using ballasted racking to secure 209 solar modules and 209 rapid-shutdown safety devices. using a flush-mounted system on the south facing roof to install 154 solar modules and 154 rapid shutdown safety devices. these fed 3 inverters that interconnect with the electrical system on the load side of the customer's 1000kva transformer
Valuation:
$494,500
Permit #:
PB240068
Status:
issued
Fee:
N/A
Permit Type:
Commercial altera...
Building Type:
N/A
Installing 19 roof mounted solar panels 7.60 kw on a single family dwelling. electrical requirements; 1). rapid shutdown or disconnecting means at solar array with external handle. 2). group mains to shut down all premises power. 3). no insulation piercing connectors
Valuation:
$29,921
Permit #:
PBLD2025-00108
Status:
issued
Fee:
$80
Permit Type:
N/A
Building Type:
N/A
Install a 500 kwac solar generation system consisting of; one thousand four hundred ninety 450 watt solar modules and five 100 kw inverters to feed into existing service. ************************************************************************************************************** required inspections: 1.special inspections. [a] 110.3.9 for special inspections see chapter 17. (if appl... see more
Valuation:
$1,100,000
Permit #:
PBC22-00214
Status:
final
Fee:
$26,749
Permit Type:
Remodel/alteration
Building Type:
N/A
Install 56 panel ground mount array pile driven post pounded posts grid tied 30.24 kw. electrical requirements; 1) rapid shutdown or disconnecting means at solar array with external handle. 2) group mains to shut down all premises power. 3) no insulation piercing connectors
Valuation:
N/A
Permit #:
PBLD2024-02002
Status:
issued
Fee:
$297
Permit Type:
N/A
Building Type:
N/A
Install 112 panel ground mount solar array pile driven post pounded posts grid tied 60.48 kw. electrical requirements; 1) rapid shutdown or disconnecting means at solar array with external handle. 2) group mains to shut down all premises power. 3) no insulation piercing connectors
Valuation:
N/A
Permit #:
PBLD2024-02001
Status:
issued
Fee:
$176
Permit Type:
N/A
Building Type:
N/A
Install 40 panel ground mount solar array pile driven post pounded posts grid tied 21.6 kw. electrical requirements; 1) rapid shutdown or disconnecting means at solar array with external handle. 2) group mains to shut down all premises power. 3) no insulation piercing connectors
Valuation:
N/A
Permit #:
PBLD2024-01999
Status:
issued
Fee:
$150
Permit Type:
N/A
Building Type:
N/A
Install 124 panel ground mount solar array pile driven post pounded posts grid tied 66.96 kw. electrical requirements; 1) rapid shutdown or disconnecting means at solar array with external handle. 2) group mains to shut down all premises power. 3) no insulation piercing connectors
Valuation:
N/A
Permit #:
PBLD2024-01990
Status:
issued
Fee:
$150
Permit Type:
N/A
Building Type:
N/A
Install roof-mounted solar generation system consisting of: 351 540watt modules feeding 3 50kilowatt inverters that interconnect an existing system within an existing external tap box with a polaris fitting
Valuation:
N/A
Permit #:
PE24000365
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install a 500 kw air conditioning solar generation system consisting of one thousand four hundred ninety 450 watt solar modules and five 100 kw inverters to feed into existing service
Valuation:
N/A
Permit #:
PE22-00673
Status:
final
Fee:
$745
Permit Type:
N/A
Building Type:
N/A
Install a roof mounted solar array per approved plans specifications and state of michigan codes
Valuation:
N/A
Permit #:
P23-0274B
Status:
final
Fee:
$449
Permit Type:
Add/alter/repair
Building Type:
N/A
Solar panel ground mount ce# 1063732145 1 service through 200 amps 1 power outlets 4 feeders 50 or fraction of 1 units up to 20 kva & hp includes 2 inspections ovid twp. section 23
Valuation:
N/A
Permit #:
PE220422
Status:
final
Fee:
N/A
Permit Type:
Electrical
Building Type:
N/A
Install 138.24kw dc ground mounted solar array
Valuation:
$107,266
Permit #:
PB250325
Status:
issued
Fee:
N/A
Permit Type:
Commercial altera...
Building Type:
N/A
Ground mounted colar array post pounded. inspections: final-
Valuation:
$31,666
Permit #:
PB230282
Status:
final
Fee:
$215
Permit Type:
Solar
Building Type:
N/A
Ground mounted solar panels. inspections: final
Valuation:
$32,944
Permit #:
PB230012
Status:
final
Fee:
$180
Permit Type:
Solar
Building Type:
N/A
10.57 ground mounted post driven solar array to offset building energy use. 20 5 x 12 (252 sq ft) 9 high **max height above grade 10 (plans lists 9 6")**
Valuation:
$35,815
Permit #:
PB210418
Status:
final
Fee:
$580
Permit Type:
Commercial altera...
Building Type:
N/A
Install a 75kwac solar generation system ground mounted line-side tap in existing service panel
Valuation:
$92,895
Permit #:
PB230604
Status:
issued
Fee:
N/A
Permit Type:
Commercial altera...
Building Type:
N/A
Solar facility - 41 rack systems inspections: footing final
Valuation:
$1,130,000
Permit #:
PB200124
Status:
final
Fee:
$4,335
Permit Type:
Solar
Building Type:
N/A
Building (residential) - alteration remodel repair
2022-05-09
Construct a 56 x 11 (595 sf) ground mounted solar array. use group r-3 5b construction
Valuation:
$20,116
Permit #:
B22-1963
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Solar panel- ground mount utility info not given 1 service through 200 amps 5 feeders 50 or fraction of 1 units up to 20 kva & hp includes 2 inspections greenbush twp. section 31
Valuation:
N/A
Permit #:
PE200503
Status:
final
Fee:
N/A
Permit Type:
Electrical
Building Type:
N/A
Similar Contractors See more
License # 2102203667
Wixom, MI
117
BZ Score
$25K
Avg Project
-
Projects
License # 262200412
Novi, MI
107
BZ Score
$6.3K
Avg Project
-
Projects
License # 262400759
Ann Arbor, MI
107
BZ Score
$25.7K
Avg Project
-
Projects
Harvest Energy Solutions Reviews
BuildZoom hasn't received any reviews for Harvest Energy Solutions. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Hiring a contractor?
Verified License
BuildZoom confirmed this contractor's license
Harvest Energy Solutions License info
Verified License
| License # | 14-0604 |
| Status | Active |
| State | Illinois |
| Business Type | Other |
- BuildZoom verified this license was active as of July 2026.
Verify this license's status for Harvest Energy Solutions at the Illinois Commerce Commission.
This is a sample of licensing data; click here to access a complete history.
Verified License
| License # | 2102218533 |
| Status | Active |
| State | Michigan |
| Type | Residential Builder Company |
| Business Type | Other |
- BuildZoom has not verified this license since January, 2025.
Verify this license's status for Harvest Energy Solutions at the Michigan Department of Licensing & Regulatory Affairs.
This is a sample of licensing data; click here to access a complete history.
Verified License
| License # | 2102218533 |
| Status | Active |
| State | Michigan |
| Type | Residential Builder Company |
| Business Type | Other |
- BuildZoom has not verified this license since June, 2025.
Verify this license's status for Harvest Energy Solutions at the Michigan Department of Licensing & Regulatory Affairs.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | L-2016-326 |
| Status | Active |
| County | Kankakee County |
| Type | Other Solar |
| Business Type | Other |
- When BuildZoom last verified this license, it had an expiration date of October, 2020. Check the current license status of Harvest Energy Solutions with the Kankakee County Planning Department
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | C117290 |
| Status | Inactive |
| State | Iowa |
| Type | Contractor |
| Business Type | Other |
- According to the Iowa Workforce Development Agency, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Harvest Energy Solutions at the Iowa Workforce Development Agency.
This is a sample of licensing data; click here to access a complete history.
107
BuildZoom Score
91
Permits
- Building permit records show that Harvest Energy Solutions has worked on 91 permitted projects.
Harvest Energy Solutions Employees
DC
Daniel Carmichael
In State Designated Agent
JT
Joel Tatum
In State Designated Agent
KB
Katina H Baker
MO
Mark Olinyk
Chief Executive Officer
MO
Mark Oliryk
SO
Sanjo Omoniyi
WB
Wendy Berry