We'll help you find the right contractor.

Share your project details and we'll reach out to Independent Power Systems, Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
I

Location and Projects

Address
2830 Wilderness Pl, Boulder, CO, 80301
Use our bidding system to request a quote

Independent Power Systems HVAC/Mechanical Contractor

Independent Power Systems, Inc, 2830 Wilderness Pl, A/B Boulder, CO (Owned by: Leo Patnode) holds a Electrical Contractor license and 49 other licenses according to the Lafayette license board.

Their BuildZoom score of 113 ranks in the top 3% of 55,949 Colorado licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Independent Power Systems, Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Independent Power Systems, Inc Services

Start a project today:

Independent Power Systems, Inc Contact Information

Phone: (303) 228-7819
Address: 2830 Wilderness Pl, A/B Boulder, CO 80301

Independent Power Systems, Inc A/B Boulder

Quality

113
97th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Independent Power Systems, Inc has a BuildZoom score of 113, which places them above 97% of 55,949 contractors in Colorado.

Activity

156 projects
2025
152 projects
2024
153 projects
2023
Our building permit records indicate that Independent Power Systems, Inc has worked on at least 461.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

14 projects
Commercial Renovations
14 projects
Home Additions
9 projects
New Constructions
196 projects
HVAC projects
70 projects
Mechanical projects
Analyzing permits over the last 4 years shows that Independent Power Systems, Inc mostly works on hvac project and mechanical project projects.

Pricing

65 projects
< $5k
101 projects
$5k-$20k
164 projects
$20k-$50k
50 projects
$50k-$100k
8 projects
$100k-$250k
2 projects
$250k-$500k
1 project
$1mil+
Value Not Public: 123.0 projects
The typical size of their permits is approximately $23,186. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Independent Power Systems, Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Building log
2025-05-13
Modified drawings for permit 2025-elec-0002783 268 x 610 q.cell q.tron xl-g2/bfg 610 system size: 163.48 kw dc stc 127.30 kw air conditioning module dimension: 96.9 x 44.6 inverter model: (268) iq8p-3p-72-e-us(208v) three-phase microinverter microinverters are installed under each module
Valuation:
$453,460
Permit #:
2025-LOG-0004177
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building log
2025-06-18
Modification to permit 2025-log-0004177 268 x 610 q.cell q.tron xl-g2/bfg 610 system size: 163.48 kw dc stc 127.30 kw air conditioning module dimension: 96.9 x 44.6 inverter model: (268) iq8p-3p-72-e-us(208v) three-phase microinverter microinverters are installed under each module
Valuation:
$400,384
Permit #:
2025-LOG-0005358
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-07-30
Roof mounted solar system; (268)610 q.cell q.tron xl-g2/bfg 610 system size: 163.48 kw dc stc 127.30 kw air conditioning inverter model: (268) iq8p-3p-72-e-us(208v) three-phase microinverter
Valuation:
$200,192
Permit #:
2025-ELEC-0002783
Status:
final
Fee:
$50
Permit Type:
N/A
Building Type:
Commercial
Electrical permit
2025-07-30
Roof mounted solar system; (268)610 q.cell q.tron xl-g2/bfg 610 system size: 163.48 kw dc stc 127.30 kw air conditioning inverter model: (268) iq8p-3p-72-e-us(208v) three-phase microinverter
Valuation:
$200,192
Permit #:
2025-ELEC-0002782
Status:
canceled
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial
Building log
2025-05-15
Solar and storage installation 25 x 430 q.cell q.tron blk m-g2+ 430 system size: 10.75 kw dc stc 8.725 kw air conditioning module dimension: 67.8 x 44.6 inverter model: (25) iq8ac-mc4(120 240v) single-phase microinverter battery system: (4) iqbattery-5p-1p-na [5kwh each; 20kwh total]
Valuation:
$66,141
Permit #:
2025-LOG-0004218
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-07-30
Modified drawings for permit 2025-elec-0002783 268 x 610 q.cell q.tron xl-g2/bfg 610 system size: 163.48 kw dc stc 127.30 kw air conditioning module dimension: 96.9 x 44.6 inverter model: (268) iq8p-3p-72-e-us(208v) three-phase microinverter microinverters are installed under each module
Valuation:
$53,076
Permit #:
2025-ELEC-0005116
Status:
final
Fee:
$50
Permit Type:
N/A
Building Type:
Commercial
Electrical permit
2025-05-19
7906 e 53rd dr - single family residence 11.18 kw photovoltaic solar system w/ess installation of solar and storage system 26 x 430 q cell q.tron blk_m-g2+ system size: 11.18 kw dc stc 11.5 kw air conditioning module dimension: 67.8 x 44.6 inverter model: (1) powerwall 3 inverter(120 240v) single-phase inverter battery system: (1) 1707000-xx-y [13.5kwh air conditioning each; 13.5kwh a... see more
Valuation:
$53,790
Permit #:
2025-ELEC-0003811
Status:
final
Fee:
$50
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2025-04-03
7906 e 53rd dr - single family residence 11.18 kw photovoltaic solar system w/ess installation of solar and storage system 26 x 430 q cell q.tron blk_m-g2+ system size: 11.18 kw dc stc 11.5 kw air conditioning module dimension: 67.8 x 44.6 inverter model: (1) powerwall 3 inverter(120 240v) single-phase inverter battery system: (1) 1707000-xx-y [13.5kwh air conditioning each; 13.5kwh a... see more
Valuation:
$53,790
Permit #:
2025-ELEC-0003512
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
Single family res...
Building log
2025-04-10
7906 e 53rd dr - single family residence 11.18 kw photovoltaic solar system w/ess installation of solar and storage system 26 x 430 q cell q.tron blk_m-g2+ system size: 11.18 kw dc stc 11.5 kw air conditioning module dimension: 67.8 x 44.6 inverter model: (1) powerwall 3 inverter(120 240v) single-phase inverter battery system: (1) 1707000-xx-y [13.5kwh air conditioning each; 13.5kwh a... see more
Valuation:
$45,692
Permit #:
2025-LOG-0002876
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2024-04-01
3401 n eudora st-mental health ctr - 2.92 kw solar system w/ess roof mounted solar photovoltaic system with battery storage; system size: 2.92kw (8) 365 rec 365np2 modules inverter model: (1) outback radian gs4048a (4) fullriver dc260-12/12v 260ah battery (12.48kwh total; 3.12kwh each)
Valuation:
$13,000,985
Permit #:
2024-ELEC-0003145
Status:
issued
Fee:
$50
Permit Type:
N/A
Building Type:
N/A
Building log
2025-08-11
Revision of permit 2024-elec-0010867 solar system installation: 81 x 590 q cells q.peak duo xl-g11s.3 bfg 590 system size: 47.79 kw dc stc 38.48 kw air conditioning module dimension: 96.9 x 44.6 inverter model: (81) iq8p-3p-72-e-us(208v) three-phase microinverter microinverters are installed under each module
Valuation:
N/A
Permit #:
2025-LOG-0006456
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical permit
2025-07-01
Installing heat-pump/mini-split: (1) mitsubishi hiwall - msz-gx09nl (1) mitsubishi hiwall - msz-gx12nl (1) mitsubishi hiwall - msz-gx18nl (1) mitsubishi floor-mounted - mfz-kx15nl (1) mitsubishi outdoor unit - mxz-sm48nlhz (1) mitsubishi branch box - pac-lma50bc electrical scope: (1) branch circuit connection
Valuation:
$30,479
Permit #:
2025-MECH-0003504
Status:
final
Fee:
$268
Permit Type:
N/A
Building Type:
Single family res...
Air conditioning furnace/boiler water heater heat pump
2025-05-13
Install heat pump/mini-split: (1) mitsubishi 24k btu floor mount air handler unit - svz-kp24na (1) mitsubishi grille unit - mlp-448wu (1) mitsubishi 6k btu concealed ceiling unit - mlz-ky06na-u1 (1) mitsubishi electric heat kit unit - eh08-svz-s (1) mitsubishi 30k btu outdoor unit - mxz-3c30nahz4-u1 (1) mitsubishi controller kit unit - mhk2 electrical scope: (1) branch circuit connect... see more
Valuation:
$25,907
Permit #:
MEP-6227-2025
Status:
issued
Fee:
$1,054
Permit Type:
N/A
Building Type:
N/A
Air conditioning furnace/boiler water heater heat pump
2025-05-21
Installing a heat pump system: (1) mitsubishi hiwall - msz-gx18nl (1) mitsubishi hiwall - msz-gx12nl (1) mitsubishi hiwall - msz-gx12nl (1) mitsubishi hiwall - msz-gx09nl (1) mitsubishi outdoor unit - mxz-sm48nlhz (1) mitsubishi branch box - pac-lma50bc electrical scope: (1) branch circuit connection
Valuation:
$26,978
Permit #:
MEP-6205-2025
Status:
final
Fee:
$1,093
Permit Type:
N/A
Building Type:
N/A
Combo permit - residential
2025-06-10
Install dual fuel heat pump/furnace system: (1) lennox gas furnace - el280uh090e48b (1) bosch ultra cased coil - bmac4248bbta (1) bosch condenser - bova-60mtb-m19e (1) ecobee thermostat - eb-state6p-01 (1) healthy climate merv filter electrical scope: (1) branch circuit connection
Valuation:
$23,819
Permit #:
B202502357
Status:
complete
Fee:
$1,045
Permit Type:
N/A
Building Type:
N/A
Combo permit - residential
2025-04-28
Installing: (1) mitsubishi 9k btu wall-mounted unit - msz-gs09na-u1 (1) mitsubishi 6k btu wall-mounted unit - msz-gs06na-u1 (1) mitsubishi 18k btu wall-mounted unit - msz-fs18na-u1 (1) mitsubishi 30k btu outdoor unit - mxz-3c30nahz4-u1 electrical scope: (1) branch circuit connection
Valuation:
$20,935
Permit #:
B202501753
Status:
complete
Fee:
$1,039
Permit Type:
N/A
Building Type:
N/A
Residential general alteration
2025-02-18
Installation of solar system--- (22) q. cell q. tron-blk-m-g2-430 modules (22) iq8ac-72-m-us(120 240v) single-phase inverter -- system size: 9.46kw dc; 7.678 kw air conditioning. incudes ev outlet installation. job contact: kyle pegon 484-477-8779
Valuation:
$32,799
Permit #:
B2501103
Status:
complete
Fee:
$980
Permit Type:
N/A
Building Type:
N/A
B-add/alt hvac residential
2025-03-11
Installation of heat pump mini split and main panel upgrade. changing old meter housing to a lever bypass 200 amp meter housing changing 150 amp outdoor panel to new 200 amp outdoor panel doing all grounding necessary to accommodate 200 amp service adding additional circ for new heat pump in solarium/sunroom. installation of only one cassette and its outdoor unit
Valuation:
$13,986
Permit #:
BP-25-00052
Status:
complete
Fee:
$583
Permit Type:
N/A
Building Type:
Residential singl...
Combo permit - residential
2025-04-15
Installing: (1) mitsubishi 12k btu wall-mounted unit - msz-fs12na-u1 (1) mitsubishi 9k btu wall-mounted unit - msz-fs09na-u1 (1) mitsubishi 6k btu wall-mounted unit - msz-fs06na-u1 (1) mitsubishi 24k btu outdoor unit - mxz-3c24nahz4-u1 electrical scope: (1) branch circuit connection
Valuation:
$12,897
Permit #:
B202501755
Status:
issued
Fee:
$721
Permit Type:
N/A
Building Type:
N/A
Residential air conditioning
2025-01-21
Installation of (1) mitsubishi 12k btu wall-mounted unit - msz-gs12na-u1 (1) mitsubishi 24k btu wall-mounted unit - msz-gs24na-u1 (1) mitsubishi 30k btu outdoor unit - mxz-3c30nahz3-u1 ele: branch circuit connection to support new heat pump system
Valuation:
$20,229
Permit #:
BDP25-0179
Status:
issued
Fee:
$278
Permit Type:
New
Building Type:
N/A

Independent Power Systems, Inc Reviews

BuildZoom hasn't received any reviews for Independent Power Systems, Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Independent Power Systems, Inc
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.