We'll help you find the right contractor.

Share your project details and we'll reach out to James Johnson Electrical Contractor Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Is this your business? Claim now >
J

Location and Projects

Address
823 4TH ST SE, Willmar, MN, 56201
Use our bidding system to request a quote

James Johnson Electrical Contractor Inc

James Johnson Electrical Contractor Inc, 823-4 Th St SE, Willmar, MN (Owned by: Johnson, James E) holds a Electrical license and 2 other licenses according to the Minnesota license board.

Their BuildZoom score of 99 ranks in the top 15% of 77,973 Minnesota licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring James Johnson Electrical Contractor Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

James Johnson Electrical Contractor Inc Services

Start a project today:

James Johnson Electrical Contractor Inc Contact Information

Phone: (320) 979-4570 Edit
Address: 823 4TH ST SE, Willmar, MN 56201 Edit

Building Permits by James Johnson Electrical Contractor Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Electrical permit
2025-03-27
Rearrange the 100 amp load center in order to install a 30 amp 2 pole breaker. install a 30 amp branch to a new heater. replace the 2 existing branch circuits with ground fault breakers. install a ground bar and isolate the ground wire
Valuation:
N/A
Permit #:
ELE2503-00867
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2025-06-10
Install a 150 amp power supply to a new bin. install a 150amp feeder to the fan controller. install a 30 amp feeder to a fused motor control. install a 3/4 hp branch to the bin spreader
Valuation:
N/A
Permit #:
ELE2410-11066
Status:
final
Fee:
$54
Permit Type:
Non-dwelling
Building Type:
N/A
Replace the damaged underground feeder to the barn. replace the power supply on the barn with a 60 amp main and reconnect 3 existing branch circuits in the barn
Valuation:
N/A
Permit #:
ELE2506-04514
Status:
final
Fee:
$77
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2023-10-09
Install a 175 amp 1 phase feeder to a 30 hp blower drive controller cabinet. install a 230 volt 20 amp branch circuit to a secondary blower and air lock operators control cabinet. install 3 cord connected interlocs to the corn dryer at 115 volts and a 230 volt cord connected branch to the air lock drive motor. connect 24 volt control between the blower drive cabinet and the operators ... see more
Valuation:
N/A
Permit #:
ELE2310-03743
Status:
final
Fee:
$52
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2023-12-08
Install a ground fault receptacle circuit for a plc controller in the dryer electrical room. mount a plc control cabinet to the dryer and connect both a 115 volt control and a 24 volt control from this new cabinet to the existing dryer control cabinet. the control cabinet was built by sukup and connected following the instructions
Valuation:
N/A
Permit #:
ELE2309-08476
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2023-09-20
Install low voltage conduit runs on the corn dryer for two sensors. install a dryer master moisture controller in the electrical building and connect the controller to the main dryer controller. install a 115 volt receptacle circuit for the dryer master controller supply
Valuation:
N/A
Permit #:
ELE2309-05377
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2023-08-02
Machine building- addition 1 outdoor flood light. shop- addition 2 outdoor lights and exhaust fan. dry storage bin- addition 1 dusk to dawn light and 1 relocate the unload auger. parts room- addition 1 outdoor dusk to dawn light. office- addition 1 outdoor entry light and indoor northeast receptacle. fuel dispensing- addition 1 extension for the pumps. garage- addition 1 new outdoor l... see more
Valuation:
N/A
Permit #:
ELE2307-05813
Status:
final
Fee:
$67
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-04-03
A mechanical rotating distributer was replaced located on the top of the fertilizer mixing tower. connect a larger horsepower drive motor. also to install a 60 amp receptacle in the electrical room. reconnect the 24 volt distributer control system
Valuation:
N/A
Permit #:
ELE2304-06035
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-06-04
Install a new laundry circuit and bathroom circuit and 100 amp feeder to a new sub panel install extensions to 2 existing circuits- basement stairway lights and bathroom fan
Valuation:
N/A
Permit #:
ELE2405-10648
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2025-08-22
Install a 2 circuit multiwire cord pendant for an appliance center located in the shop area. two-ground fault receptacles for convenience
Valuation:
N/A
Permit #:
ELE2503-12832
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2022-08-30
Install a 100 amp feeder to a new corn leg install a 100 amp power supply on leg install 5 circuits to leg equipment tie in 1 15 amp circuit to existing dryer install a feeder to bin #4 receptacle and feeder to bin #7 receptacle for portable auger use
Valuation:
N/A
Permit #:
ELE2208-12272
Status:
final
Fee:
$108
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-05-13
Install a 400 amp 1 phase service (2) 200 amp feeders to motor drives (2) 60 amp feeders to equipment (2) 100 amp motor branch circuits (4) 0-30 amp branch circuits and 3 low voltage controls
Valuation:
N/A
Permit #:
ELE2311-05592
Status:
final
Fee:
$98
Permit Type:
Non-dwelling
Building Type:
N/A
Install a 400 amp 460 volt feeder to the new motor starter cabinet a 60 amp feeder to a 115/230 volt power supply. install 16 460 volt motor branch circuits 1 115 volt control circuit and 36 low voltage control cicuits
Valuation:
N/A
Permit #:
ELE2205-08157
Status:
final
Fee:
$171
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-08-12
Install a ground fault circuit from the house to the septic pedestal for the pump. install a 15 amp circuit to the septic pedestal alarm
Valuation:
N/A
Permit #:
ELE2408-00328
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Electrical permit
2021-12-07
Replace existing pole disconnect with a new load center. install a new 30 amp underground feeder to the well location. install load center at well and branch circuit to pressure tank/well pump. install 115 volt receptacle at both locations
Valuation:
N/A
Permit #:
ELE2112-02794
Status:
issued
Fee:
$60
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2024-12-17
The electrical permit ele2212-06467 expires on 12/20/23. the final on this cannot be completed because the owner has not completed the interior walls
Valuation:
N/A
Permit #:
ELE2312-06252
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2022-12-06
Install 3 ground fault circuits with 5 convenience outlets in the southeast area of the machine shed. install 1 50amp 230volt feeder to compressor unit and 1 ground fault service receptacle
Valuation:
N/A
Permit #:
ELE2212-01673
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2021-11-23
Install a temporary power supply to a new fuel storage tank. a future building to be built to surround this tank. the temporary is supplied with a 15 amp 115 volt branch circuit from the existing fuel storage shed and feeds the fuel pump
Valuation:
N/A
Permit #:
ELE2111-06067
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2022-08-30
The owner requested the utility to reconnect the 3 phase service to his bin site after a requested disconnect for a length of time. the utility requires an inspection before reconnect
Valuation:
N/A
Permit #:
ELE2208-12271
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Electrical permit
2021-11-23
Remove a 250 amp feeder tap and install a 350 amp tap to a new dryer controller. reconnect all existing motor branch circuits to this new controller. install a new gate controller with interlocs to the existing system
Valuation:
N/A
Permit #:
ELE2111-06006
Status:
final
Fee:
$63
Permit Type:
Non-dwelling
Building Type:
N/A

Similar Contractors See more

License # EA002557
114
BZ Score
$5K
Avg Project
-
Projects
License # EL003800EC
112
BZ Score
$7.7K
Avg Project
-
Projects
License # AM007019
115
BZ Score
$500
Avg Project
-
Projects

James Johnson Electrical Contractor Inc Reviews

BuildZoom hasn't received any reviews for James Johnson Electrical Contractor Inc. Click here to be alerted when reviews are posted about them.
Please write a review about James Johnson Electrical Contractor Inc
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.