Updated: Jul 09, 2025
Location and Projects
Address
23 Comanche Rd, Fairmont, NC, 28340
Use our bidding system to
request a quote
James Jones Jr HVAC/Mechanical Contractor
James Jones Jr, 23 Comanche Rd, Fairmont, NC holds a license according to the South Carolina license board.
Their BuildZoom score of 104 ranks in the top 9% of 101,103 North Carolina licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring James Jones Jr, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
James Jones Jr Contact Information
Address: 23 Comanche Rd, Fairmont, NC 28340
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
James Jones Jr Fairmont
Quality
104
91st percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
James Jones Jr has a BuildZoom score of 104, which places them above 91% of 101,103 contractors in North Carolina.
Activity
|
10 projects
|
2025 |
|
18 projects
|
2024 |
|
8 projects
|
2023 |
Our building permit records indicate that James Jones Jr has worked on at least
36.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
21 projects
|
Mechanical projects |
|
21 projects
|
HVAC projects |
Analyzing permits over the last 4 years shows that James Jones Jr mostly works on
hvac project
and mechanical project
projects.
Pricing
|
3 projects
|
< $5k |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Replacing 2ton heat/pump package unit with gas/electric package unit. run 20’ coated 1/2copper gas line under home from 2psi gas meter to regulator then adapting to iron for package unit connection. made contact with guc to confirm meter is adequate for additional 70k btu to existing service. adding 7” supply diffuser in floor in living room. home does not have a supply in the living ... see more
Valuation:
N/A
Permit #:
MECH-2023-0209
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Replacement of 1.5ton split system heat/pump serving upstairs of home. installing 1.5ton 15.2seer2 split system heat/pump. replacing existing 12 return flex serving unit to 14 flex. reuse existing supply ductwork
Valuation:
N/A
Permit #:
MECH-2024-1255
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2025-05-30
Replacement of 1.5ton split system heat/pump serving upstairs of home. installing 1.5ton 15.2seer2 split system heat/pump. replacing existing 12 return flex serving unit to 14 flex. reuse existing supply ductwork
Valuation:
N/A
Permit #:
ELSP-2024-1721
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of 2ton counter flow split system heat pump serving downstairs. installing 15.6seer2 2ton counter flow split system heat pump with new line set. reuse existing supply ductwork. common air return
Valuation:
N/A
Permit #:
ELSP-2024-1779
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of 2.5ton split system heat pump to 2.5ton 15.4seer2 split system heat pump. reusing existing supply ductwork and return stack. installing new return starter plenum with new 14 flex to existing return stack. adding 12x12x8"flex return to master bedroom
Valuation:
N/A
Permit #:
MECH-2023-1417
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2024-06-04
Replacement of 2.5ton split system heat pump to 2.5ton 15.4seer2 split system heat pump. reusing existing supply ductwork and return stack. installing new return starter plenum with new 14 flex to existing return stack. adding 12x12x8"flex return to master bedroom
Valuation:
N/A
Permit #:
ELSP-2023-2015
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacing existing 2.5ton gas/electric package unit serving downstairs with 2.5ton gas/electric package unit 14seer/70k btu heat. using existing supply and return ductwork. replacing existing gas line 1/2 black iron due to it being buried with 5/8 acr copper routed through crawl to unit less than 30’
Valuation:
N/A
Permit #:
MECH-2023-1257
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2024-04-15
Replacing existing 2.5ton gas/electric package unit serving downstairs with 2.5ton gas/electric package unit 14seer/70k btu heat. using existing supply and return ductwork. replacing existing gas line 1/2 black iron due to it being buried with 5/8 acr copper routed through crawl to unit less than 30’
Valuation:
N/A
Permit #:
ELSP-2023-1771
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacing existing 3ton gas/electric package unit with 3ton 14seer 90k btu gas/electric package unit using existing supply and return ductwork. replacing existing 1/2 acr copper gas line to 5/8 acr copper routed through crawl space to unit
Valuation:
N/A
Permit #:
MECH-2023-1258
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2024-04-15
Replacing existing 3ton gas/electric package unit with 3ton 14seer 90k btu gas/electric package unit using existing supply and return ductwork. replacing existing 1/2 acr copper gas line to 5/8 acr copper routed through crawl space to unit
Valuation:
N/A
Permit #:
ELSP-2023-1772
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of 1.5ton split system heat pump with 5kw heat strip serving upstairs of home. running new line set and modifying return duct work for proper size. reusing existing supply ductwork
Valuation:
N/A
Permit #:
MECH-2023-0391
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2023-10-23
Replacement of 1.5ton split system heat pump with 5kw heat strip serving upstairs of home. running new line set and modifying return duct work for proper size. reusing existing supply ductwork
Valuation:
N/A
Permit #:
ELSP-2023-0603
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2023-11-22
Replacement of upstairs 1.5ton split system heat/pump with new line set and pedestal box/emergency pan. reusing existing supply and return duct. 5kw heat strip. 17seer/15.8seer2 equipment
Valuation:
N/A
Permit #:
ELSP-2023-0844
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of upstairs 1.5ton split system heat/pump with new line set and pedestal box/emergency pan. reusing existing supply and return duct. 5kw heat strip. 17seer/15.8seer2 equipment
Valuation:
N/A
Permit #:
MECH-2023-0532
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Replacing existing 2.5ton gas package unit and starter ducts with 3ton 2stage cooling/2stage heating 15seer2 gas package unit. replace disconnect box/whip reconnect new unit
Valuation:
N/A
Permit #:
ELSP-2023-0319
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing 3ton gas/electric package unit to 14seer 3ton gas/electric package unit. reusing existing supply and return duct. reusing existing gas line
Valuation:
N/A
Permit #:
MECH-2024-0387
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Replacement of 2ton counter flow split system heat pump serving downstairs. installing 15.6seer2 2ton counter flow split system heat pump with new line set. reuse existing supply ductwork. common air return
Valuation:
N/A
Permit #:
MECH-2024-1296
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Replacement of 17seer 2ton ductless mini split to 21.5seer2 1.5ton ductless mini split serving bonus room over car garage. re using existing line set
Valuation:
N/A
Permit #:
MECH-2024-0216
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2024-08-28
Replacement of 17seer 2ton ductless mini split to 21.5seer2 1.5ton ductless mini split serving bonus room over car garage. re using existing line set
Valuation:
N/A
Permit #:
ELSP-2024-0332
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical sub permit change out (mechanical unit)
2024-06-04
Replacing 2ton gas/electric package unit that serves bedroom side of home with 2ton 14seer gas/electric package unit. re using existing supply and return ducts. re using existing gas line
Valuation:
N/A
Permit #:
ELSP-2023-2016
Status:
linked
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
License # 01387
Fayetteville, NC
111
BZ Score
$9.7K
Avg Project
-
Projects
License # L.05098
Pinebluff, NC
108
BZ Score
$8.4K
Avg Project
-
Projects
License # U.37137
Fayetteville, NC
108
BZ Score
$20.9K
Avg Project
-
Projects
James Jones Jr Reviews
BuildZoom hasn't received any reviews for James Jones Jr. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Verified License
BuildZoom confirmed this contractor's license
James Jones Jr License info
Verified License
| License # | 40655 |
| Status | Active |
| State | South Carolina |
- BuildZoom has not verified this license since September, 2013.
Verify this license's status for James Jones Jr at the South Carolina Contractor's Licensing Board.
This is a sample of licensing data; click here to access a complete history.
104
BuildZoom Score
26
Permits
- Building permit records show that James Jones Jr has worked on 26 permitted projects.
James Jones Jr Employees
JJ
James Jones
Owner