We'll help you find the right contractor.

Share your project details and we'll reach out to Johnson Controls Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >

Location and Projects

Address
3826 THIRLANE ROAD NW #1, Roanoke, VA, 24019
Use our bidding system to request a quote

Johnson Controls Construction

Johnson Controls Inc, 3826 Thirlane Rd NW, Roanoke, VA (Employees: Christopher Michael Osborne and Justin Michael Turner) holds a Electrical (Ele), Heating Ventilation And Air Conditioning (Hva), Plumbing (Plb), Gas Fitting (Gfc) license and 6 other licenses according to the Virginia license board.

Their BuildZoom score of 108 ranks in the top 5% of 131,387 Virginia licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Johnson Controls Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Johnson Controls Inc Contact Information

Phone: (423) 349-6109 Edit
Address: 3826 THIRLANE ROAD NW #1, Roanoke, VA 24019 Edit

Johnson Controls Inc Roanoke

Quality

108
95th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Johnson Controls Inc has a BuildZoom score of 108, which places them above 95% of 131,387 contractors in Virginia.

Activity

172 projects
2025
171 projects
2024
151 projects
2023
Our building permit records indicate that Johnson Controls Inc has worked on at least 494.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

29 projects
Home Additions
26 projects
Commercial Renovations
8 projects
New Constructions
56 projects
Kitchen remodels
Analyzing permits over the last 4 years shows that Johnson Controls Inc mostly works on kitchen remodel and home addition projects.

Pricing

161 projects
< $5k
96 projects
$5k-$20k
49 projects
$20k-$50k
25 projects
$50k-$100k
9 projects
$100k-$250k
6 projects
$250k-$500k
4 projects
$500k-$1mil
1 project
$1mil+
Value Not Public: 142.0 projects
The typical size of their permits is approximately $6,778. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Johnson Controls Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Commercial fire
2025-02-05
Fire alarm - complete fire alarm and vesda air aspiration smoke detection systems for the facility. the system will be a ul listed globally addressable system with horn/strobe notification devices consisting of the following: control panels: a three (3) node 4100es system with node 1 being a network display unit (ndu) node located in the noc room 130 with a services gateway connection... see more
Valuation:
$934,732
Permit #:
20250205-025
Status:
issued
Fee:
$7,110
Permit Type:
Alarm
Building Type:
N/A
Commercial fire
2024-12-18
Fire alarm - install a complete fire alarm and vesda air aspiration smoke detection systems for the facility. the system will be a ul listed globally addressable system with horn/strobe notification devices. chirisa ctp 02 data hall/chirisa data center
Valuation:
$934,732
Permit #:
20241218-025
Status:
canceled
Fee:
N/A
Permit Type:
Alarm
Building Type:
N/A
Brookdale virginia beach <<< fire alarm contr to replace existing failing facp with new addressable simplex 4007es facp if manual pull station is not present one shall be povided smoke detector over facp shall be installed if one is not present existing fire pump points to be monitored hvac duct smoke detectors shall send a supervisory signal to monitoring all field initiating applian... see more
Valuation:
$38,894
Permit #:
2025-FIRE-12589
Status:
filed
Fee:
$335
Permit Type:
N/A
Building Type:
N/A
Fire protection - sprinkler
2025-06-10
Emergency repair replacement of (1) ames 2000ss backflow preventor; replacement of 21 feet of 3” pipe in attic cut to fit and mechanical tee’s replaced. the existing locations of this valve pipe and fittings will not be altered. the scope of work is limited to a one-for-one replacement. all piping and other system components to remain as originally installed
Valuation:
$9,260
Permit #:
FPP2025-00962
Status:
issued
Fee:
$277
Permit Type:
N/A
Building Type:
N/A
Residence inn note: must provide unintended motion and ascending car protection. <<< fire alarm contr to tie into existing addressable simplex 4100es facp and will be providing any and all requirements for the elevator modifications heat detectors and smoke detectors in locations as required for compliance all work to be performed in compliance with 2019 nfpa 72 standards
Valuation:
$7,110
Permit #:
2025-FIRE-11543
Status:
final
Fee:
$177
Permit Type:
N/A
Building Type:
N/A
Interior alterations - virginia beach psychiatric hospital lobby renovation - use group i-2 construction type 2a sprinklered <<< fire alarm contr to provide fire break relays for access control contrs temporary lobbies maglocks all work to be performed in compliance with 2019 nfpa 72 standards
Valuation:
$6,316
Permit #:
2025-FIRE-06941
Status:
complete
Fee:
$172
Permit Type:
N/A
Building Type:
N/A
New tenant building out - funnybone comedy club restaurant and arcade - use group a-1 a-2 a-3 construction type 2b sprinklered fire alarm ***occupant load 467 based on seating count <<< kitchen fire suppression contr to provide code compliant protection for two new type i hoods and cooklines captiveaire overlapping coverage system to be utilized for both systems hood #1- 12 gallon tan... see more
Valuation:
$5,000
Permit #:
2025-FIRE-06223
Status:
final
Fee:
$162
Permit Type:
N/A
Building Type:
N/A
New tenant building out - the grill - use group a-2 construction type 1a sprinklered ***occupant load 261 <<< ( 11/3/25 revised ) kitchen fire suppression contr to provide code compliant protection for 2 new type i hoods and cooklines ( fire alarm tie-in required ) simultaneous shutdown of both type i hoods and cooklines electric gas valve to be utilized for equipt. shutdown ansul 15 ... see more
Valuation:
$5,500
Permit #:
2025-FIRE-05526
Status:
final
Fee:
$192
Permit Type:
N/A
Building Type:
N/A
Security (c) - alter/remodel light
2025-06-25
Johnson controls security solutions (jci) will install a new software house access control system for one reader. jci will run cat 5/composite cable and provide a power supply door controller 1 door contact 1 wall mount card reader and an exit detector. there are no maglocks in this system
Valuation:
N/A
Permit #:
SECC-147712-2025
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New tenant building out - mi vida - use group a-2 construction type 1a sprinklered ***occupant load 375 <<< ( 10/29/25 captiveaire designers letter uploaded in documents explaining hood #2 cad drawing descrepancy ) kitchen fire suppression contr to provide code compliant protection for two new type i hoods and cooklines captiveaire overlapping coverage system to be utilized for both s... see more
Valuation:
$4,800
Permit #:
2025-FIRE-06072
Status:
final
Fee:
$162
Permit Type:
N/A
Building Type:
N/A
New restaurant - atlantic park - milk & honey - use group a-2 construction type 1a sprinklered **occupant load 152 <<< kitchen fire suppression contr to provide code compliant protection for new type i hood and cookline captiveaire 12 gallon tank ( over lapping coverage ) system to be utilized 60 flow points available 52 flow points to be used 8 flow points left remaining fire alarm t... see more
Valuation:
$2,200
Permit #:
2025-FIRE-05575
Status:
complete
Fee:
$151
Permit Type:
N/A
Building Type:
N/A
New tenant building out - parlor doughnuts - use group a-2 construction type 2b non-sprinklered ***occupant load 62 <<< kitchen fire suppression permit obtained to confirm that code complaince has been maintained throughout alterations existing type i hood contr installed the original 8 gallon captiveaire tank system ( overlapping coverage ) 40 flow points available 24 flow points use... see more
Valuation:
$1,100
Permit #:
2025-FIRE-02084
Status:
complete
Fee:
$146
Permit Type:
N/A
Building Type:
N/A
Commercial fire permit
2025-03-11
Hookup and test of a new tank (8) gallon electric wet chemical system using overlapping coverage. electric gas valve to be used. system is factory installed in a type i mechanical hood installed by others. 40 flows available 40 flows used
Valuation:
$2,250
Permit #:
BLD-FIRE-COM-2025-00017
Status:
complete
Fee:
$116
Permit Type:
N/A
Building Type:
N/A
Commercial fire permit
2025-03-06
Existing zone fire alarm panel (thorn auto call/mdk-2) to be replaced with addressable simplex 4007es panel. new 4007 es panel will have (8) zones to accommodate devices being added to area under construction
Valuation:
$58,919
Permit #:
BLD-FIRE-COM-2025-00013
Status:
complete
Fee:
$792
Permit Type:
N/A
Building Type:
N/A
Commercial electrical new construction
2023-12-06
Johnson controls security installing complete security control access control system. includes istar access control panels (52) readers power supplies rex motions (4) lane turstile for the scope of work that includes the tenant build-out (level i and ii alteration) of all office areas maintenance area and battery charging area *battery charging area will require additional permits and... see more
Valuation:
$253,094
Permit #:
ELEC-004061-2023
Status:
complete
Fee:
$2,786
Permit Type:
N/A
Building Type:
N/A
Commercial fire permit
2024-04-03
Provide labor and materials to install (1) 4100es facp which will interface with the existing pyrotronics mxl system. the 4100es and associated panel materials have been configured to allow for a migration of the existing pyrotronics system to the simplex system as the customer's needs and budget allows. this 4100es system installation will include monitoring modules for the proposed ... see more
Valuation:
$79,603
Permit #:
BLD-FIRE-COM-2023-00065
Status:
complete
Fee:
$852
Permit Type:
N/A
Building Type:
N/A
Commercial fire permit
2025-07-03
This is a one for one replacement. existing is an fci fc-72 facp and silent knight 5104 dact and will be replaced with a simplex 4007es facep. a existing wiring to remain and be reused. existing field devices will be replaced with new at the existing locations with the existing back boxes and existing wires. current system does not have a remote annunciator
Valuation:
$27,301
Permit #:
BLD-FIRE-COM-2025-00137
Status:
complete
Fee:
$539
Permit Type:
N/A
Building Type:
N/A
New tenant build-out for restaurant ***wiseguy pizza*** a-2 use vb construction non-sprinklered occupant load 49 <<< kitchen fire suppression contr to provide code compliant protection for new type i hood and cookline captiveaire tank system ( overlapping coverage ) 4 gallon system 20 flow points available 12 flow points to used 8 flow points remaining ( fire alarm tie-in required ) f... see more
Valuation:
$2,000
Permit #:
2025-FIRE-26348
Status:
final
Fee:
$146
Permit Type:
N/A
Building Type:
N/A
Fire alarm (c) - alter/remodel light
2025-09-12
Retreat doctors hospital sterilizers 3rd floor - jcfp to modify the existing simplex fire alarm system. relocate and demolish existing devices. addition (1) ceiling mounted audio/visual in clean work room addition (1) ceiling mounted visual only in sterile storage room replace (1) existing mapnet smoke detector in clean work with a new idnet smoke detector addition (1) idnet smoke det... see more
Valuation:
N/A
Permit #:
FIRC-154125-2025
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New construction - le bon enfants daycare - use group i-4 construction type 5b non-sprinklered *** total occupant load to include all areas 176 *** ***classroom 104 -- 6wks to 9 mos - 11 occupants - 8 infants - 3 staff*** ***classroom 105 -- 6wks to 9 mos - 11 occupants - 8 infants - 3 staff*** ***classroom 107 -- 6wks to 9 mos - 11 occupants - 8 infants - 3 staff*** ***classroom 110 ... see more
Valuation:
$2,250
Permit #:
2025-FIRE-15342
Status:
complete
Fee:
$151
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 2705158238
146
BZ Score
$10K
Avg Project
-
Projects
License # 2705182158
153
BZ Score
$24.8K
Avg Project
-
Projects
License # 2705184628
147
BZ Score
$82.5K
Avg Project
-
Projects

Johnson Controls Inc Reviews

BuildZoom hasn't received any reviews for Johnson Controls Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Johnson Controls Inc
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.