Updated: Sep 26, 2024
Location and Projects
Address
4002 Glen Rdg, Gainesville, GA, 30507
Use our bidding system to
request a quote
Jose Antonio Galvan HVAC/Mechanical Contractor
Their BuildZoom score of 0 does not rank in the top 50% of Georgia contractors.
If you are thinking of hiring Jose Antonio Galvan, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Jose Antonio Galvan Contact Information
Address: 4002 Glen Rdg, Gainesville, GA 30507
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Jose Antonio Galvan Gainesville
Quality
Alert*
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
*No active license on file. If you are Jose Antonio Galvan, click “This is My Business” to update your information.
Activity
|
60 projects
|
2024 |
|
140 projects
|
2023 |
Our building permit records indicate that Jose Antonio Galvan has worked on at least
200.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
140 projects
|
New Constructions |
|
3 projects
|
Home Additions |
|
52 projects
|
HVAC projects |
|
3 projects
|
Mechanical projects |
Analyzing permits over the last 4 years shows that Jose Antonio Galvan mostly works on
new construction
and hvac project
projects.
Pricing
|
41 projects
|
$100k-$250k |
The typical size of their permits is approximately $120,000. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
New single family home - cir2023-00036
Valuation:
$210,416
Permit #:
RESBLD2023-02721
Status:
final
Fee:
$1,288
Permit Type:
N/A
Building Type:
N/A
152 westside bend system placement- 3.5 ton zone in basement mechanical room zoned- yes (3 zones) dampers- 1-14” 3rd 1-12” 2nd and 1-12” 2nd bypass- 1-12” lineset- 1-50’x7/8” b-vent- no waterheater- no floor boots- yes venthood- no 14” flex- yes bathroom fans- 5-4 (5- sidewall caps) *metal plenums *run drain to the outside (clear vinyl) *seal all seams on dryer vent with tape and mast... see more
Valuation:
N/A
Permit #:
BM-202403492
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
2940 springside place se system placement- 2 ton in attic*horizontal dampers- no bypass- no lineset-1-50'x3/4 b-vent- no waterheater- no floor boots- no 14 flex- no venthood- 6” venthood out of the roof *need to frame 4” below the box bathroom fans- 2-4 **(2- sidewall) *metal plenums *all r6 *install (1) 4sa and (1) 4ra in the attic *need to install aprilaire 8145 fresh air fan *need ... see more
Valuation:
N/A
Permit #:
BM-202403470
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
2948 springside place se system placement- 3 ton zone in utility closet dampers- 2-12 bypass- 1-10 lineset- 1-75'x3/4 b-vent- no waterheater- no floor boots- yes 14 flex- yes venthood- yes “6 *6’ then the sidewall (pipe needs to be 4” below the box bathroom fans- 3-4 **(2- 4 sidewall 2- 4 cornice 1- 6 sidewall) *metal plenums *bubble wrap *seal all connections like right choice *need ... see more
Valuation:
N/A
Permit #:
BM-202403468
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
489 village creek se *gps* 3116 browns mill road se system placement- 3 ton zone in knee wall *horizontal dampers- 2-12 bypass- 1-10 lineset- 1-75'x3/4 b-vent- no waterheater- no floor boots- no 14 flex- yes venthood- yes “6 *6’ then the sidewall (pipe needs to be 4” below the box bathroom fans- 3-4 **(2- 4 sidewall 2- 4 cornice 2- 6 sidewall) *metal plenums *bubble wrap *need to inst... see more
Valuation:
N/A
Permit #:
BM-202403467
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
163 westside bend system placement- 3.5 ton zone in basement mechanical room zoned- yes (3 zones) dampers- 1-14” 3rd 1-12” 2nd and 1-12” 2nd bypass- 1-12” lineset- 1-50’x7/8” b-vent- no waterheater- no floor boots- yes venthood- no 14” flex- yes bathroom fans- 5-4 (2- sidewall caps 3-cornice caps) *metal plenums *run drain to the outside (clear vinyl) *seal all seams on dryer vent wit... see more
Valuation:
N/A
Permit #:
BM-202403378
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
151 westside bend system placement- 3.5 ton zone in basement mechanical room zoned- yes (3 zones) dampers- 1-14” 3rd 1-12” 2nd and 1-12” 2nd bypass- 1-12” lineset- 1-50’x7/8” b-vent- no waterheater- no floor boots- yes venthood- no 14” flex- yes bathroom fans- 5-4 (2- sidewall caps 3-cornice caps) *metal plenums *run drain to drain hub *seal all seams on dryer vent with tape and masti... see more
Valuation:
N/A
Permit #:
BM-202403213
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
150 westside bend system placement- 3.5 ton zone in attic *horizontal zoned- yes (3 zones) dampers- 1-14” 3rd 1-12” 2nd and 1-12” 2nd bypass- 1-12” lineset- 1-75’x7/8” b-vent- no waterheater- no floor boots- no venthood- no 14” flex- yes bathroom fans- 5-4 (2- sidewall caps 3-cornice caps) *metal plenums *run drain to washer box *seal all seams on dryer vent with tape and mastic *need... see more
Valuation:
N/A
Permit #:
BM-202403030
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
8 blanche street nw system placement- 3 ton zone in utility closet dampers- 2-12 bypass- 1-10 lineset- 1-50'x3/4 b-vent- no waterheater- no floor boots- yes 14 flex- yes venthood- no bathroom fans- 3-4 *metal plenums *run drain pvc to the side of the house *need to tape and mastic all seams on dryer vent (including elbow seams) *need metal wire on dryer vent for support (no black webb... see more
Valuation:
N/A
Permit #:
BM-202302784
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 6/6/23 1106 mantissa street nw system placement- 3 ton zone (1) main (2) basement in the basement 3 ton upstairs in the attic *horizontal dampers- 3-12” bypass- 1-10” lineset-1-30’x3/4” 1-75'x3/4 b-vent- no *concentric vents waterheater- no *tankless floor boots- yes 14 flex- yes venthood- yes *6” bathroom fans- 6-4 *metal plenums (bubble wrap) *run upstairs drain to... see more
Valuation:
N/A
Permit #:
BM-202302747
Status:
issued
Fee:
$405
Permit Type:
N/A
Building Type:
New
2632 brown street nw system placement- 2 ton in crawl *horizontal dampers- no bypass- no lineset-1-30'x3/4 b-vent- no waterheater- no floor boots- yes 14 flex- yes venthood- no bathroom fans- 2-4 **all bathroom fans out the rear sidewall-not the cornice *metal plenums *seal all connections like right choice *need to tape all seams on dryer vent *dryer vent needs to go down into the cr... see more
Valuation:
N/A
Permit #:
BM-202302604
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
3000 delta way se * gps* 3116 browns mill road se system placement- 2 ton in crawl *horizontal dampers- no bypass- no lineset-1-30'x3/4 b-vent- no waterheater- no floor boots- yes 14 flex- yes venthood- no bathroom fans- 2-4 **all bathroom fans out the rear sidewall-not the cornice *metal plenums *seal all connections like right choice *need to tape all seams on dryer vent *dryer vent... see more
Valuation:
N/A
Permit #:
BM-202302296
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
534 james p brawley drive nw system placement- 2 ton in attic*horizontal dampers- no bypass- no lineset-1-30'x3/4 b-vent- no waterheater- no floor boots- no 14 flex- yes venthood- no bathroom fans- 2-4 **all bathroom fans out the rear sidewall-not the cornice *metal plenums *seal all connections like right choice *need to tape all seams on dryer vent *dryer vent needs to go down into ... see more
Valuation:
N/A
Permit #:
BM-202302295
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 4/26/23 23 skylar **gps: 1155 hill st se atlanta ga 30315 system placement- 3 ton zone terrace/main/upstairs in garage mechanical room zoned- yes zone dampers- 1-10” 2-12” bypass- 1-10” lineset- n lineset *will run it later. need to cut holes for the future b-vent- no waterheater- no floor boots- yes (main level and upstairs) 14 flex- yes venthood- no bathfans- 4-4” ... see more
Valuation:
N/A
Permit #:
BM-202302076
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 4/26/23 25 skylar **gps: 1155 hill st se atlanta ga 30315 system placement- 3 ton zone terrace/main/upstairs in garage mechanical room zoned- yes zone dampers- 1-10” 2-12” bypass- 1-10” lineset- n lineset *will run it later. need to cut holes for the future b-vent- no waterheater- no floor boots- yes (main level and upstairs) 14 flex- yes venthood- no bathfans- 4-4” ... see more
Valuation:
N/A
Permit #:
BM-202302074
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 4/26/23 24 skylar **gps: 1155 hill st se atlanta ga 30315 system placement- 3 ton zone terrace/main/upstairs in garage mechanical room zoned- yes zone dampers- 1-10” 2-12” bypass- 1-10” lineset- n lineset *will run it later. need to cut holes for the future b-vent- no waterheater- no floor boots- yes (main level and upstairs) 14 flex- yes venthood- no bathfans- 4-4” ... see more
Valuation:
N/A
Permit #:
BM-202302071
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 4/26/23 26 skylar **gps: 1155 hill st se atlanta ga 30315 system placement- 3 ton zone terrace/main/upstairs in garage mechanical room zoned- yes zone dampers- 1-10” 2-12” bypass- 1-10” lineset- n lineset *will run it later. need to cut holes for the future b-vent- no waterheater- no floor boots- yes (main level and upstairs) 14 flex- yes venthood- no bathfans- 4-4” ... see more
Valuation:
N/A
Permit #:
BM-202302069
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 4/26/23 27 skylar **gps: 1155 hill st se atlanta ga 30315 system placement- 3 ton zone terrace/main/upstairs in garage mechanical room zoned- yes zone dampers- 1-10” 2-12” bypass- 1-10” lineset- n lineset *will run it later. need to cut holes for the future b-vent- no waterheater- no floor boots- yes (main level and upstairs) 14 flex- yes venthood- no bathfans- 4-4” ... see more
Valuation:
N/A
Permit #:
BM-202302067
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 4/26/23 22 skylar **gps: 1155 hill st se atlanta ga 30315 system placement- 3 ton zone terrace/main/upstairs in garage mechanical room zoned- yes zone dampers- 1-10” 2-12” bypass- 1-10” lineset- n lineset *will run it later. need to cut holes for the future b-vent- no waterheater- no floor boots- yes (main level and upstairs) 14 flex- yes venthood- no bathfans- 4-4” ... see more
Valuation:
N/A
Permit #:
BM-202302050
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Walk notes – cory 4/26/23 21 skylar **gps: 1155 hill st se atlanta ga 30315 system placement- 3 ton zone terrace/main/upstairs in garage mechanical room zoned- yes zone dampers- 1-10” 2-12” bypass- 1-10” lineset- n lineset *will run it later. need to cut holes for the future b-vent- no waterheater- no floor boots- yes (main level and upstairs) 14 flex- yes venthood- no bathfans- 4-4” ... see more
Valuation:
N/A
Permit #:
BM-202302048
Status:
issued
Fee:
$175
Permit Type:
N/A
Building Type:
New
Similar Contractors See more
License # GACN210795
Ellenwood, GA
111
BZ Score
$43.2K
Avg Project
-
Projects
130
BZ Score
$4.7K
Avg Project
-
Projects
License # CR110385
Atlanta, GA
115
BZ Score
$40K
Avg Project
-
Projects
Jose Antonio Galvan Reviews
BuildZoom hasn't received any reviews for Jose Antonio Galvan. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an HVAC pro in your area today
We'll search our vast network of HVAC Pros and connect
you with one that meets your needs today.
Jose Antonio Galvan License info
License Not Verified
| License # | CR109618 |
| Status | Active |
| State | Georgia |
| Type | Conditioned Air |
- When BuildZoom last verified this license, it had an expiration date of November, 2023. Check the current license status of Jose Antonio Galvan with the Georgia Department of Professional Licensing
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are Jose Antonio Galvan, click “This is My Business” to update your information.
201
Permits
- Building permit records show that Jose Antonio Galvan has worked on 201 permitted projects.