We'll help you find the right contractor.

Share your project details and we'll reach out to Joseph T. Williams so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Is this your business? Claim now >

Location and Projects

Address
705 64th Ave, Philadelphia, PA, 19126
Use our bidding system to request a quote

Joseph T. Williams Solar Contractor

Joseph T. Williams at 705 64th Ave, Philadelphia, PA 19126, held a Solar Contractor license (#PA070501) with the Pennsylvania contractors license board with an expiration date of 06-25-2012. We last verified the license was expired on 05-09-2025.

Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 125,106 Pennsylvania contractors.

If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.

Joseph T. Williams Services

Start a project today:

Joseph T. Williams Contact Information

Phone: (215) 279-2405 Edit
Address: 705 64th Ave, Philadelphia, PA 19126 Edit

Joseph T. Williams Philadelphia

Quality

Alert*
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
*No active license on file. If you are Joseph T. Williams, click “This is My Business” to update your information.

Activity

1 project
2025
1 project
2023
Our building permit records indicate that Joseph T. Williams has worked on at least 2.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Pricing

2 projects
$5k-$20k
Value Not Public: 0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Joseph T. Williams

Sort by: Notable Notable | Date Date | Job Value Job Value
General permit minor
2025-09-09
For minor construction work at the subject property in accordance with all applicable provisions of the philadelphia code all references codes and standards and the attached ez standard where included. deviation from this standard shall result in permit revocation. a separate permit from the philadelphia department of streets is required for any sidewalk and street closures. all means... see more
Valuation:
$7,100
Permit #:
GM-2025-006483
Status:
complete
Fee:
N/A
Permit Type:
Ez roof covering ...
Building Type:
N/A
Electrical permit
2011-12-27
161 receptacles 46 gfci's 80 lights 14 exit lights, existing service. **service upgrade required. additional permits calculations and plans for service and feeders required prior to energizing any loads** as per 2008 nec (west dist)
Valuation:
N/A
Permit #:
362000
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2011-10-07
250 amp service (90) receptacles, (25) switches (18) gfci's (25) lights (3) heat pumps (3) electric stoves (3) hot water heaters, as per 2008 nec (15) smoke detectors, fire alarm system as per nfpa-72 (north dist)
Valuation:
N/A
Permit #:
351730
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2010-11-19
<<<interior alterations>>> applicant agrees to limit the construction to comply with ez permit standard for interior alterations dated feb. 2007. deviations from this standard will result in the revocation of this permit and imposition of further penalties
Valuation:
N/A
Permit #:
312670
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-12-17
400amp service 4 meters 3 heat pumps 3 hot water heater 34 lits 2 em battery units 120 rec. 18 gfci 42 switches fire alarm 2 smoke dec 1 pull station 11 audio visual signal per 2008 nec
Valuation:
N/A
Permit #:
408828
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-06-07
400amp service 5 meter 5 feeders 95 recepts 30 switches 38 lights 20 smoke det 5 emerg lights 36 gfci 4 heat pumps as per 2008 nec(north dist) fire alarm as per nfpa 72 wire 4 famiy dwelling
Valuation:
N/A
Permit #:
403174
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2009-04-02
Replace damaged devices remove serv cable/ser cable feeding panels that are not being used. install existing junction box covers & support the boxes and support cables throughout basement ceiling, all work in basement only as per 2005 nec (west dist)
Valuation:
N/A
Permit #:
208387
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2012-10-12
Installation of solar photovoltaic system with associated mounting system per plans at the roof level of an exisitng structure. separate electrical permit required
Valuation:
N/A
Permit #:
419080
Status:
COMPLETED
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2008-04-28
New 200 amp service 63 receptacles 20 switches 26 lights 2 hot water heater 3000 watts (2) 1-ton heat pumps smoke detectors interconnect gfi receptaclels 2 circuit in kitchen and 1 circuit in bathroom as per 2005 nec (north dist)
Valuation:
N/A
Permit #:
148225
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-01-13
6fd-500 amp svc , 7 panels, rec (70)switches (30) lites (60).(20) smoke dtectors (15) gfci (6) heat pumps all electrical ; fire alarm as per 2008 nec and as specified per plans (south district)
Valuation:
N/A
Permit #:
377721
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2011-05-19
**no new wiring or relocations under this permit** replace electrical panels 120 receptacles 20 gfci's 30 lights smoke detectors and fire alarm devices; all in kind using existing wiring.(west dist)
Valuation:
N/A
Permit #:
341853
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2011-07-19
Install 350amp service 65 recepts 40 switches 16 gfci 10 smoke detectors 3 heat pumps 3 stoves and 3 hot water heaters as per 2008 nec ( north district) install fire alarm system as per nfpa 72
Valuation:
N/A
Permit #:
350538
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-01-13
200amp service 39 receptacles 10 lights 11 switches 6 smoke detectors 6 gfcis heat pump stove hot water heater as per 2008 nec( south district) single family dwelling
Valuation:
N/A
Permit #:
383115
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-02-27
300a service 4 meters fire alarm exit and emergency lts 3 heat pumps 140 recepts 40 sw 30 lts 3 strobes 3 hwhw and 10 gfci recepts as per 2008 nec(3fd)(south dist)
Valuation:
N/A
Permit #:
384660
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
200amp service 3 panels 45 rec 15 switches 7 gfci 8 smoke det 2 heat pumps 2 stoves 2 hot water heaters all electrical as per 2008 nec (north dist) 2 family dwelling
Valuation:
N/A
Permit #:
395005
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2011-07-19
3 phase 800 amp 12 meters plus 1 house meter 150 receptacles 25 switches 100 lights 12 heat pumps 12 electric stoves 12 hot water heaters as per 2008 nec and fire alarm system as per nfpa-72
Valuation:
N/A
Permit #:
339734
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-04-27
Dentist office- install new 52 lights, 30 rec 22 switches (1 air compressor wire) and replace in kind 20 lights 14 recepts and 8 switches as per 2008 nec (east district)
Valuation:
N/A
Permit #:
379196
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2011-02-24
Replace wiring change 40 receptacles and 18 switches replace 3 horns and 3 pull stations disconnect/reconnect relocated office partitions no new wiring as per 2008 nec (east dist)
Valuation:
N/A
Permit #:
326478
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2011-10-03
200 amp service 28 receptacles 6 switches 8 lights 3 gfci's 5 smoke detectors 1 heat pump 1 hot water heater 1 stove all as per 2008 nec (south dist)
Valuation:
N/A
Permit #:
366261
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2009-03-31
600 amp service (4) 200a disconnects (1) 100a disconnect (4) 200 amp panels (1) 100 amp panel (4) heat pumps 4 tons each (44) receptacles (35) lights (4) gfci receptacles as per 2005 nec (east dist)
Valuation:
N/A
Permit #:
204466
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

HIC # 13VH11809100
116
BZ Score
$7.5K
Avg Project
-
Projects
HIC # 13VH07951800
111
BZ Score
$16.3K
Avg Project
-
Projects
HIC # CR-25-0058
107
BZ Score
$14.9K
Avg Project
-
Projects

Joseph T. Williams Reviews

BuildZoom hasn't received any reviews for Joseph T. Williams. Click here to be alerted when reviews are posted about them.
Please write a review about Joseph T. Williams
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.