We'll help you find the right contractor.

Share your project details and we'll reach out to K Butler Electric so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
K

Location and Projects

Address
1220 Monte Vista Ct, Benicia, CA, 94510
Use our bidding system to request a quote

K Butler Electric

K Butler Electric, 1220 Monte Vista Ct, Benicia, CA holds a Electrical license according to the California license board.

Their BuildZoom score of 107 ranks in the top 6% of 336,931 California licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring K Butler Electric, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

K Butler Electric Contact Information

Phone: (707) 745-1230
Address: 1220 Monte Vista Ct, Benicia, CA 94510

K Butler Electric Benicia

Quality

107
94th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
K Butler Electric has a BuildZoom score of 107, which places them above 94% of 336,931 contractors in California.

Activity

2 projects
2025
16 projects
2024
43 projects
2023
Our building permit records indicate that K Butler Electric has worked on at least 61.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

60 projects
Electrical projects
Analyzing permits over the last 4 years shows that K Butler Electric mostly works on electrical project projects.

Pricing

33 projects
< $5k
22 projects
$5k-$20k
1 project
$50k-$100k
Value Not Public: 5.0 projects
The typical size of their permits is approximately $4,500. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by K Butler Electric

Sort by: Notable Notable | Date Date | Job Value Job Value
Install dedicated circuits for kitchen appliances. install low voltage undercabinet kitchen lighting and recessed ceiling lights and dimmer switches in kitchen. install new lighting and power in pantry. install (2) bathroom exhaust fans with humidity sensing switches in two separate bathrooms. install recessed ceiling lights and vacancy switch in primary bathroom and power for (3) doc... see more
Valuation:
N/A
Permit #:
EW202505286730
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Energy improvements
2024-02-15
No Description Available
Valuation:
N/A
Permit #:
B-24-68
Status:
suspended
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building - residential electrical
2023-10-06
Replace 100 amp 120/240 volt 1 ph 3 wire main meter service with new 200 amp 120/240 volt 1 ph 3 wire service. also install new 100 amp 240 volt subpanel in garage. new subpanel will feed existing & will be supplied with all new circuit breakers. subpanel to be fed from the main metered service
Valuation:
$8,150
Permit #:
BIE23-011828
Status:
issued
Fee:
$301
Permit Type:
N/A
Building Type:
N/A
Building - residential electrical
2022-10-28
Repair existing electrical service - remove the existing riser conduit coming out of the top of the main electric service. provide and install a new 2 inch rigid riser conduit from the top of the existing panel on the exterior of the house and offset around the existing gutter (please note this estimate may need to be modified if pg&e requests a different installation style). the new ... see more
Valuation:
N/A
Permit #:
BIE22-012400
Status:
final
Fee:
$133
Permit Type:
N/A
Building Type:
N/A
Building - residential electrical
2022-09-01
- install a new nema 3r (outdoor rated) 100 amp 240 volt sub-panel. the new siemens/murray sub-panel will feed existing new and future circuits in the garage. the sub-panel will be fed from the existing siemens 200 amp service. a 1-1/4 inch pvc conduit will be installed in a customer/solar company supplied trench - install (2) dedicated 30 amp 240 volt circuits to provide power to (2)... see more
Valuation:
$4,400
Permit #:
BIE22-009954
Status:
final
Fee:
$205
Permit Type:
N/A
Building Type:
N/A
Building - residential electrical
2022-04-19
- install a new outdoor nema 3r weatherproof 100 amp 240 volt sub-panel located on the back right corner of the house. the new sub-panel will feed the new backyard circuits and will be supplied with all new circuit breakers. the sub-panel will be fed from the main metered service
Valuation:
N/A
Permit #:
BIE22-004168
Status:
final
Fee:
$198
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-01-12
No Description Available
Valuation:
$9,700
Permit #:
E-24-5
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Energy improvements
2023-09-25
Provide a 40 amp 240 volt circuit for customer provided evc. new breaker will be fed from existing eaton main service. k butler electric will mount & connect customer provided evc on the wall inside of the garage
Valuation:
$745
Permit #:
B-23-118
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2023-08-25
510 buckeye court - goodrum-125amp underground solar ready main electric service like for like (no relocation needed)-install (1) 15 amp circuit for bedroom power.-install (2) future circuits for backyard
Valuation:
$4,900
Permit #:
E-23-13
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building Permit
2022-09-23
- install a new 400 amp main meter service in the same location the existing service islocated. the new overhead service will control a new 200 amp subpanel. the subpanelwill have distribution for all the new circuits.-like-for-like house re-wire to remove knob and tube undergrounded wiring. all areas outside of permit 22-1392 are under the 2019 chbc service panel is under cec2019
Valuation:
$8,775
Permit #:
BLD-22-1128
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building Permit
2022-12-20
- install a new like for like 200 amp 120/240 volt 1 ph 3 wire main dual meter service. the new 200amp service will replace the existing 200 amp 120/240 volt 1 ph 3 wire dual meteredservice. the new overhead service will control the existing 100 amp subpanels. the reason for the replacement is from water damage
Valuation:
$5,500
Permit #:
BLD-22-1397
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building Permit
2022-01-20
- provide and install a 20 amp 120 volt squared homeline breaker. run approximately 35 to 40 ft of conduit from the main panel to the area in the garage where the new laundry station will be set up. install a 2 gang junction box to allow for 4 places to be plugged into. the circuit will provide power for a all-in-one washer and dryer that requires 10 amp. and a pedestal washing machin... see more
Valuation:
$875
Permit #:
BLD-22-100
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building Permit
2022-09-06
Commercial electrical tbdx design - relocate 30 amp receptacle and 20 amp receptacle on the wall outside the bathrooms to the opposite side of the wall.- provide and install a dedicated 20 amp 208 volt single phase circuit for the existing air compressor located on the back left corner of the warehouse. the new circuit will be fed from the main panel on the back wall of the warehouse.... see more
Valuation:
$3,300
Permit #:
BLD-22-1057
Status:
suspended
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2023-08-16
No Description Available
Valuation:
$7,000
Permit #:
E-23-12
Status:
suspended
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building - residential electrical
2023-06-20
Install 1 100 amp sub panel. damp circuit for induction cooktop, 2 receptacles for garage and attic , l keuless lampholder and switch in attic
Valuation:
$5,860
Permit #:
BIE23-007437
Status:
final
Fee:
$287
Permit Type:
N/A
Building Type:
N/A
Electrical
2023-07-18
- provide a 60 amp 240 volt circuit for a customer provided electric vehicle charger (evc).- relocate the existing hot tub disconnect to be a minimum 5 feet away from the hot tub
Valuation:
$1,550
Permit #:
E-23-2
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2023-10-12
200amp overhead solar ready existing main service panel; provide and install (1) 30 amp 240 volt 4 wire circuit; provide and install (2) 50 amp 240 volt circuits
Valuation:
$7,075
Permit #:
E-23-21
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Energy improvements
2023-09-25
No Description Available
Valuation:
$750
Permit #:
B-23-117
Status:
suspended
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2023-09-26
Install a 50 amp 240 volt gfci protected circuit for an electric vehicle charger (evc).the new breaker will be fed from the existing main eaton electric service
Valuation:
$930
Permit #:
E-23-19
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building Permit
2023-04-25
Main service panel upgrade 200 amps (1) 50 amp 240 volt circuit for ev charger*the msp changeout must meet surge protection requirements of cec 230.67*
Valuation:
$5,750
Permit #:
BLD-23-478
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

K Butler Electric Reviews

BuildZoom hasn't received any reviews for K Butler Electric. Click here to be alerted when reviews are posted about them.
Please write a review about K Butler Electric
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.