We'll help you find the right contractor.

Share your project details and we'll reach out to Kaback Enterprises so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

K

Location and Projects

Address
318 W 39th St, New York, NY, 10018
Use our bidding system to request a quote

Kaback Enterprises Plumber

Kaback Enterprises, 318 W 39th St, New York, NY holds a Fire Suppression Contractor B license and 2 other licenses according to the New York license board.

Their BuildZoom score of 114 ranks in the top 2% of 77,888 New York licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Kaback Enterprises, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Kaback Enterprises Services

Start a project today:

Kaback Enterprises Contact Information

Phone: (917) 439-6926
Address: 318 W 39th St, New York, NY 10018

Kaback Enterprises New York

Quality

114
98th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Kaback Enterprises has a BuildZoom score of 114, which places them above 98% of 77,888 contractors in New York.

Activity

68 projects
2025
102 projects
2024
53 projects
2023
Our building permit records indicate that Kaback Enterprises has worked on at least 223.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

13 projects
Commercial Renovations
13 projects
Home Additions
152 projects
Plumbing projects
Analyzing permits over the last 4 years shows that Kaback Enterprises mostly works on plumbing project and home addition projects.

Pricing

15 projects
< $5k
59 projects
$5k-$20k
64 projects
$20k-$50k
41 projects
$50k-$100k
44 projects
$100k-$250k
14 projects
$250k-$500k
6 projects
$500k-$1mil
4 projects
$1mil+
Value Not Public: 0 projects
The typical size of their permits is approximately $35,031. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Kaback Enterprises

Sort by: Notable Notable | Date Date | Job Value Job Value
Mechanical systems
2025-05-08
Mechanical alteration for existing building. scope includes replacement of existing (2) air-cooled split-system air conditioning with (3) split-system heat pump. existing distribution ductwork and diffusers to remain
Valuation:
$209,000
Permit #:
M01193946-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Sprinklers
2025-01-26
Furnish & install new sprinkler booster pump associated fcva sprinkler/standpipe risers and piping (harry winston infrastructure) as per plans. no change to use egress or occupancy
Valuation:
$259,400
Permit #:
M08025961-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical systems
2025-03-04
Proposed work shall include the replacement of (2) water-source heat pump units. reconnect to existing condenser water pipe with new insulation. provide new condensate drain pipe to terminate at existing slop sink. existing ducts and diffusers to remain
Valuation:
$96,000
Permit #:
M01096401-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical systems
2025-03-20
Proposed work shall include the replacement of (2) water-source heat pump units. reconnect to existing condenser water pipe with new insulation. provide new condensate drain pipe to terminate at existing slop sink. existing ducts and diffusers to remain
Valuation:
$95,000
Permit #:
M01091459-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Installation of new sprinkler heads and piping installation of pre-action sprinkler system and removal of tcsp. and installation of new fixtures and associated piping on the 6th floor
Valuation:
$222,336
Permit #:
M01163645-I1-PL
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Scope of work under this applications includes new plumbing fixtures and associated domestic water and sanitary piping within the area of work. scope of work includes new sprinklers and piping throughout the area of work
Valuation:
$564,999
Permit #:
Q01114840-I1-PL
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Plumbing
2025-04-14
Modification of plumbing fixtures and sprinkler system as per plans filed herewith no change in use egress or occupancy under this application
Valuation:
$1,355,864
Permit #:
M01144077-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Sprinklers
2025-04-14
Modification of plumbing fixtures and sprinkler system as per plans filed herewith no change in use egress or occupancy under this application
Valuation:
$932,536
Permit #:
M01144068-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Sprinklers
2025-01-03
Sprinkler modifications to take place on the 18th construction floor as per plans filed herewith. no change in use egress or occupancy. (listed as 22nd marketing floor)
Valuation:
$230,050
Permit #:
M00927362-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical systems
2025-02-07
Direct replacement of (4) new single packaged air conditioning units on roof (1) new split system outdoor heat pump unit and (1) new split system indoor heat pump unit in 1st floor mechanical room. existing ducts and refrigerant lineset to remain
Valuation:
$65,700
Permit #:
B01120970-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
A2 - alteration type 2
2025-01-31
Modification to existing mechanical system including modification to existing sprinkler system as per plans filed herewith. no change in use egress or occupancy in this application
Valuation:
$180,000
Permit #:
104241991-02-EW-SP
Status:
issued
Fee:
$1,943
Permit Type:
N/A
Building Type:
N/A
Mechanical systems
2024-07-01
Proposed work to replace existing cooling tower and indoor water-cooled heat pump serving existing bank. install new dx cooling split system. existing air distribution ductwork to remain
Valuation:
$400,000
Permit #:
M01005818-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Sprinklers
2025-02-16
Modifications to the existing sprinkler system: remove (253) existing sprinkler heads install (43) new temporary sprinkler heads and (5) new permanent heads and associated sprinkler piping on the 25th floor as per plans (ll work - demolish & restrooms.)
Valuation:
$22,800
Permit #:
M00988376-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Sprinklers
2025-03-01
Modifications to the existing sprinkler system: installation of (4) new sprinkler heads and associated sprinkler piping and provide (2) new sprinkler control valve assemblies on the ground floor as per plans (retail demising project - annex f.)
Valuation:
$15,000
Permit #:
M00906119-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical systems
2024-07-01
Removal of existing 8-ton and 15-ton indoor air handling units in existing mechanical room. installation of new 15-ton split system outdoor unit on 2nd floor roof setback and installation of new 15-ton split system indoor unit in basement tenant space
Valuation:
$150,000
Permit #:
M00914628-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Sprinklers
2024-06-28
Modification to exisiting sprinkler system on floors 20 21 and 23 (listed as 24 25 and 27 marketing floors) per plans filed herewith. no change in use egress or occupancy
Valuation:
$615,000
Permit #:
M00842313-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Additions/modifications to existing plumbing & sprinkler systems. no change in use egress or occupancy
Valuation:
$537,000
Permit #:
M00957155-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Sprinklers
2025-01-22
Modifications to the existing sprinkler system on the cellar floor (harry winston - cellar fit-out) as per plans. no change to use egress or occupancy
Valuation:
$200,000
Permit #:
M01092172-I1-EW-SP
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical systems
2024-12-31
In-kind replacement of (2) split system heat pump condensing units and (11) split system heat pump air handling units. existing energy recovery unit to be refurbished and remain. existing ducts to remain and new piping to replace existing piping in-place
Valuation:
$125,000
Permit #:
Q01032743-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Northwell health overbuild fit-out project: installation of plumbing & sprinkler fixture fit-outs @ third and fourth floor shell space of new overbuild maternity addition; also includes minor pl scope @ 1st floor as per plans filed herewith
Valuation:
$3,314,000
Permit #:
S00422592-I1-PL
Status: