Updated: Feb 16, 2026
Location and Projects
Address
Madisonville, LA, 70447
Use our bidding system to
request a quote
Kastner Electric, Inc
Kastner Electric, Inc, Madisonville, LA (Employees: Rickey J. Kastner Sr. and Rickey John Kastner Jr.) holds a Electrical license according to the Louisiana license board.
Their BuildZoom score of 107 ranks in the top 6% of 31,948 Louisiana licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Kastner Electric, Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Kastner Electric, Inc Contact Information
Phone Number: (985) 643-9258
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Kastner Electric, Inc Madisonville
Quality
107
94th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Kastner Electric, Inc has a BuildZoom score of 107, which places them above 94% of 31,948 contractors in Louisiana.
Activity
|
12 projects
|
2025 |
|
11 projects
|
2024 |
|
5 projects
|
2023 |
Our building permit records indicate that Kastner Electric, Inc has worked on at least
28.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
3 projects
|
Commercial Renovations |
|
28 projects
|
Electrical projects |
Analyzing permits over the last 4 years shows that Kastner Electric, Inc mostly works on
electrical project
and commercial renovation
projects.
Pricing
|
3 projects
|
< $5k |
|
2 projects
|
$5k-$20k |
The typical size of their permits is approximately $5,469. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
Building Permits by Kastner Electric, Inc
This is a sample of this contractor's permits. Click here to access their complete permit history.
Residential electrical connection (effective 8/11/2022) residential electrical permit (effective 8/1
2025-05-02
Replace existing automatic transfer switch and existing generator with new 26kw generator. cleco account 200002337109 marla helvestonflood zone a reconnect existing gas whip to new generator
Valuation:
N/A
Permit #:
2025-2306
Status:
applied
Fee:
N/A
Permit Type:
Generator (r)
Building Type:
Generator
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2024-11-14
Emergency reconnect - replace damaged meter socket (cleco pulled meter); install main disconnect on exterior of house; install whole house surge protector; update grounding; reconnect existing electrical panel; separate grounds and neutrals in existing electrical panel since adding new main disconnect on exterior of house
Valuation:
N/A
Permit #:
2024-7098
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Electrical
Commercial electrical connection (effective 8/11/2022), commercial electrical permit (effective 8/11
2024-07-15
Tornado damage: free-standing disconnect switch on the building was damaged by a fallen tree during the tornado. the disconnect switch is damaged needs to be removed from service a scheduled outage is needed to remove the disconnect switch from the electrical service.planed outage scheduled with cleco 7/15/2024.cleco account # 200003006265
Valuation:
N/A
Permit #:
2024-4343
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Electrical
: emergency reconnect - meter pulled due to burned meter lug. replace existing meter with new 200a 120/240v single-phase underground meter; per 2020 nec addition new outdoor disconnect and surge protector; separate ground and neutrals in existing panel. entergy account 11214046 sylvia t kreger
Valuation:
$2,519
Permit #:
24-08524-ERPR
Status:
issued
Fee:
$100
Permit Type:
N/A
Building Type:
Building use group
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2024-03-11
Replace damaged existing main lug only panel with new 200a main circuit breaker panel; relocate 3 circuits from sub panel to new main breaker panel; addition surge protector. will need release to cleco reconnect. cleco 200003018617 michael foley
Valuation:
N/A
Permit #:
2024-1238
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Gas
Commercial electrical connection (effective 8/11/2022) commercial electrical permit (effective 8/11/
2025-03-17
Commercial electrical permitelectrical work for billboard replace damaged electrical panel 100a single phase. cleco 200001092366
Valuation:
N/A
Permit #:
2025-1380
Status:
issued
Fee:
N/A
Permit Type:
Electrical (c)
Building Type:
Electrical
Commercial electrical connection (effective 8/11/2022) commercial electrical permit (effective 8/11/
2025-03-17
Install 200a 120/240v single-phase overhead electrical service and two digital sign circuits for billboard. cleco 200000222782
Valuation:
N/A
Permit #:
2025-1379
Status:
issued
Fee:
N/A
Permit Type:
Electrical (c)
Building Type:
Electrical
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2024-07-03
Install 26kw generator 200a ats change meter socket install whole house surge protector change all smoke detectors to combination co/smoke detectors. drawings attached. cleco account #210002669922 ralph kastnerflood zone c
Valuation:
N/A
Permit #:
2024-3329
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Electrical
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2023-05-26
Emergency reconnect - cleco disconnected customer for a problem on the utility side and would not reconnect customer until electrician checked service. service checked - no issues. ready for emergency reconnect
Valuation:
N/A
Permit #:
2023-2455
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Accessory
: emergency reconnect - apartment a meter socket burned and damaged. replacing existing meterstack with new for apartments a b c and d. 100a single phase each
Valuation:
$5,469
Permit #:
25-21208-SERV
Status:
issued
Fee:
$73
Permit Type:
N/A
Building Type:
Building use group
: emergency reconnect - apartment a meter socket burned and damaged. replacing existing meterstack with new for apartments a b c and d. 100a single phase each
Valuation:
$5,469
Permit #:
25-21207-SERV
Status:
issued
Fee:
$73
Permit Type:
N/A
Building Type:
Building use group
: emergency reconnect - apartment a meter socket burned and damaged. replacing existing meterstack with new for apartments a b c and d. 100a single phase each
Valuation:
$5,469
Permit #:
25-21206-SERV
Status:
issued
Fee:
$73
Permit Type:
N/A
Building Type:
Building use group
: emergency reconnect - apartment a meter socket burned and damaged. replacing existing meterstack with new for apartments a b c and d. 100a single phase each
Valuation:
$5,469
Permit #:
25-21204-SERV
Status:
issued
Fee:
$73
Permit Type:
N/A
Building Type:
Building use group
Residential electrical connection (effective 8/11/2022) residential electrical permit (effective 8/1
2025-03-19
Install 18kw generator and 200a transfer switch.flood zone c run 6 gas line above ground from meter to generator
Valuation:
N/A
Permit #:
2025-1198
Status:
applied
Fee:
N/A
Permit Type:
N/A
Building Type:
Roof
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2024-11-05
Flood zone amove existing generator to be 5ft from house; correct feeders from meter to existing ats; install whole house surge protector; install co detectors as required in bedrooms and living areas. moving a installed generator away from the house and bring it up to code. moving gas line 5ft to new generator location
Valuation:
N/A
Permit #:
2024-6780
Status:
applied
Fee:
N/A
Permit Type:
N/A
Building Type:
Electrical
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2024-07-15
Flood zone cseparate ats permit for project 2023-404; install 400a single-phase automatic transfer switch whole house surge protection device and combination co/smoke detectors as required
Valuation:
N/A
Permit #:
2024-4241
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Electrical
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2024-05-22
Replace existing 200a meter socket and existing automatic transfer switch with new; replace existing whole house surge protector. cleco 200001556477 robert qualey
Valuation:
N/A
Permit #:
2024-2619
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Remodel
Commercial electrical connection (effective 8/11/2022) commercial electrical permit (effective 8/11/
2025-03-11
Replace damaged 100a single phase electrical panel. cleco # 200001090253
Valuation:
N/A
Permit #:
2025-1183
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Roof
Residential electrical connection (effective 8/11/2022), residential electrical permit (effective 8/
2022-09-30
Install new 20’ pole with 100a 120/240v single-phase meter socket and panel feeding one 240v 30a well pump (existing equipment) and one light switch and gfci receptacle in the pump house
Valuation:
N/A
Permit #:
2022-6677
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Electrical
Commercial electrical connection (effective 8/11/2022), commercial electrical permit (effective 8/11
2024-04-15
Replace existing damaged electrical service with new 200a main circuit breaker panel with surge protector. lamar advertising cleco # 210002925969
Valuation:
N/A
Permit #:
2024-1941
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Electrical
Similar Contractors See more
License # 37893
Prairieville, LA
110
BZ Score
$5K
Avg Project
-
Projects
License # 54402
Covington, LA
110
BZ Score
-
Avg Project
-
Projects
License # 58792
Slidell, LA
109
BZ Score
-
Avg Project
-
Projects
Kastner Electric, Inc Reviews
BuildZoom hasn't received any reviews for Kastner Electric, Inc. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Verified License
BuildZoom confirmed this contractor's license
Kastner Electric, Inc License info
Verified License
| License # | 11950 |
| Status | Active |
| State | Louisiana |
| Type | Electrical |
| Class | Commercial License Certificate |
- BuildZoom verified this license was active as of February 2026.
Verify this license's status for Kastner Electric, Inc at the Louisiana Licensing Board.
This is a sample of licensing data; click here to access a complete history.
107
BuildZoom Score
557
Permits
- Building permit records show that Kastner Electric, Inc has worked on 557 permitted projects.
Kastner Electric, Inc Employees
RS
Rickey J. Kastner Sr.
RJ
Rickey John Kastner Jr.