Share your project details and we'll reach out to
Kelly John Mj Kelly Electric Inc
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Kelly John Mj Kelly Electric Inc, 240 Wynnewood Ave, Philadelphia, PA (Employees: John Kelly and Mj Kelly Electric, Inc.) holds a Electrical Contractor license and 1 other license according to the Philadelphia license board.
Their BuildZoom score of 100 ranks in the top 13% of 125,106 Pennsylvania licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Kelly John Mj Kelly Electric Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
This job space includes: - 40 lighting fixtures - 61 receptacles as per 2017 nec. install the following fire alarm devices: - 10 speaker strobes - 13 heat smoke detectors - 15 duct smoke detectors as per 2016 nfpa 72
For a level ii alterations to an existing structure. alterations to include the erection of partition walls provide finishes/furnishings and accessibility improvements throughout.**structural work included as part of the scope of work** building is fully sprinklered. all work to be done per approved plans. if field conditions vary contact design professional prior to the start of any ... see more
(238) fixtures (1) fa panel (1) duct detector (25) smoke detectors (36) speaker/strobes (3) strobes (1) single (115) duplex (12) duplex gfi (99) quad (2) quad gfi. all work is to be done according to approved drawings-2017 nec, 2016 nfpa-72, 2018 phila fire code
(1) 800 amp house distribution panel (7) branch electrical panels (1) 800 amp apartment meter bank (50) hp fire pump (1) 80 kw diesel gen (643) led light fixture (1194) receptacles as per approved -2017 nec. **separate fire alarm permit required for any fire alarm**
For level ii alterations to an existing health facilty to include the erection of partition walls provide finishes/furnishings and accessibility improvements. alterations to include the installation of a laboratory accessory to the health facility. all work to be done on the 6th floor level. building is fully sprinklered. all work to be done per approved plans. if field conditions var... see more
For interior level 2 alteration at the basement level of a detached structure for an existing school as per plans. no change in occupancy classification
Installation of (12) 2x2 led lights (7) chain hung led lights (15) 20 amp receptacles various lab equipment connections (2) 225 amp panels (2) 30 kva transformers (2) 100 amp panels (2) air compressors. all work to be done according to approved drawings **no fire alarm on this permit, separate permit required**
New construction of a five (5) story structure to include vacant commercial space (use registration & fit-out permits required prior to occupancy) thirty-seven (37) dwelling units and accessory parking as per approved plans. fire retardant treated studs and sheathing required in exterior walls for type iii construction. building to be fully sprinklered per nfpa 13 and include standpip... see more
New 2 story building. 800 amp service including peco padmount transformer 7 branch electrical panels 1 75kva transformer 2 45kva transformers lighting and branch receptacles throughout. complete fire alarm system per nfpa 72 and 2017 nec.(east dis new 2 story building. 800 amp service including peco padmount transformer 7 branch electrical panels 1 75kva transformer 2 45kva transforme... see more
25 layin led lights 6 switches 10 occ sensors 44 20 amp receptacles per 2017 nec (west dist) install fire alarm system for renovation 4 strobes, 3 horn/strobes , 2 duct detectors.'16 nfpa-72
Installation of 18-recepts, relocate 12-2x4 lights and 11-downlights, install 4-new 2x4 lights on an existing service as per 2008 nec (west district) rework existing fire alarm system devices in current space as per nfpa72
Installation of (20) 2x4 led lay in lights (7) 2x2 lights (10) down lights (3) pendant lights (11) battery packs (2) exits (7) under counter lights (18) switches (1) new branch panel lp-9c (81) receptacles (12) heat pumps (1) split system fire alarm adjustments for new floor plan
Installation of (243) led light fixtures (22) exit signs associated lighting controls branch circuit receptacles as indicated for new offices as per 2017 nec. fire alarm per attached shop drawings and nfpa 72
For level i alterations to include new flooring ceiling tiles and paint throughout new fixtures and service counters as per approved plans. no structural work. separate permits required for all mep and fire suppression work
Install 2-100amp panels associated feeder, install 1-45kva transformer and 1-150amp panel, lighting and branch power for mri support space as per 2008 nec (west district) fire alarm is on ap#942078
100 amp sub-panel; circuit for hot water heater hvac unit connections new kitchen branch circuits and appliance circuits new high hat lighting throughout as per 2014 nec
Installation of new 100 amp service. complete rough-in and finish for house. all new branch wiring receptacles and lighting as per 2014 nec building permit #1046616 but will not go into the place it needs to be
Modifications to an existing fire alarm system including 4 duct detectors 32 smoke detectors 25 strobes 23 speaker strobes as per nf pa 72 (cc dist) 17 nec, 16 nfpa-72
Installation of (6) 20 amp branch receptacle circuits. 32 receptacle locations. replace (20) 2x2 led light fixtures with new lights in same locations as per 2017 nec
BuildZoom verified this license was active as of July 2026.
Verify this license's status for Kelly John Mj Kelly Electric Inc at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
Inactive License
HIC #
PA128586
Status
Inactive
State
Pennsylvania
According to the Pennsylvania Office of the Attorney General, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Kelly John Mj Kelly Electric Inc at the Pennsylvania Office of the Attorney General.
This is a sample of licensing data; click here to access a complete history.